SEP - Important Data Notes PDF
Document Details
Uploaded by QualifiedIolite7081
ICBT Campus, Sri Lanka
Tags
Related
- Frontier Flight Attendant Initial Training Emergency Equipment PDF
- Frontier Flight Attendant Documentation PDF
- Zen Air CH-701 STOL Standard Operating Procedures PDF
- NAVY AIR FORCE EMERGENCY PROCEDURES PDF
- A320 Emergency Equipment Initial Training PDF
- Smartwings Cabin Crew Operations Manual - Emergency Situations PDF
Summary
This document contains important data and handouts for easy reference, focusing on aircraft safety procedures. It details aspects such as oxygen systems, slide rafts, and communication, providing useful guidelines for various aircraft models.
Full Transcript
IMPORTANT DATA HANDOUTS FOR EASY REFERENCE 1. Oxygen Flight Deck Cabin Portable Kit Location Avionics Bay PSU/overhead OHB/Compartment Type Gaseous Chemically Gaseous...
IMPORTANT DATA HANDOUTS FOR EASY REFERENCE 1. Oxygen Flight Deck Cabin Portable Kit Location Avionics Bay PSU/overhead OHB/Compartment Type Gaseous Chemically Gaseous generated Capacity 3256 Lt 310 Lt Duration of 15 min Oxygen Kit Oxygen 4 Lt – 75 Min (High Outlet) 2 Lt – 150 Min (Low Outlet) Cylinder Pressure 1850 psi 1850 psi Regulating Press. 65 – 94 psi - - ECAM PAGE Reg. Lo. Press < 50 psi Warning on ECAM MEL Req. For Ex CMB Oxygen Kits. A 330 Min.1500 psi - 14kits A 320 -do- - 05kits A 321 -do- - 08kits En Route A 330 - 08 kits 06 @ 1000 psi 02 @ 500 psi A 320 - 04 kits 03 @ 1000 psi 01 @ 500 psi A 321 - 05 kits Over pressure @ 30,000 ft. starts Cabin Alt. Automatically Hypoxia @ 40000 ft 10 sec. @ 35000 ft 20 sec. TUC @ 40000ft 10 sec. @ 35000 ft 20 sec. Green Disc on the Cylinder High Fuselage will not Pressure at be there when >2500 psi & OXYGEN Release Low Pressure system activates at >175 psi 2. Slide Raft Fleet Total Capacity Capacity Remarks Rafts (Normal) (Overload) A 320 04 44 55 02 Over Wing Slides A 321 04 44 55 08 Escape Slides A 330 -200 06 Door (1&4) 65 78 Door No. 3 only an Escape Slide Door (2) 55 68 ALH A330 - 200 & 08 Door (3) 50 60 A330 - 300 3. Fire Extinguishers (Halon – BCF) Fleet Flight Deck Avionics Bay Cabin Total A 320 01 -- 05 06 A 321 01 -- 07 08 A 330 01 01 08 10 DURATION & EFFECTIVE RANGE OF HALON Duration is 9 SEC Effective Range is 10 Feet Checks to be done on Ground Disadvantage Seal & Pin Intact/Needle in the green Comparatively Low Cooling Effect zone & Easy Access 4. Communication Command for Brace PNF (Pilot non flying) “Brace Brace Brace” May Day Distress Message May Day May Day Pan Pan Urgency Pan Pan Pan Pan Nature NITS Briefing Intention Time Available Special Information 5. Raft Duties in a Ditching – A, B, C, D, T & E A - Sea Anchor B – Radio Beacon C – Canopy, Survival Kit & Hand Pump D – Sea Dye Marker T – Tie all Rafts together E – Erect Canopy Task Method Detach the Raft Lift the Velcro cover, pull the disconnect handle Use the hook knife in the upper tube of the raft & cut from Cut Mooring Line the door sill end Move minimum of 100 Use see Anchor / Oars (Only in330 SRAK) meters away Carry Out A,B,C,D,T,E, Deploy Sea Anchor Attached to the Raft Deploy Beacon Tie it to the Raft & throw it to water (make sure to turn the switch to on position of the ATD 406 AP & Kannad 406 AS). *ADT 406 AP - Duration 60 Hrs / Satellite 24 Hrs *Kannad 406 AS - Duration 48 Hrs / Satellite 24 Hrs *Rescue 406 - Duration 48 Hrs / Satellite 24 Hrs Survival Kit (Canopy & Retrieve items floating in the water from the Door Sill End Hand Pump) of the Raft. Dye Maker (Deploy) Tear off the cover & tie the lanyard to the raft *Sea Dye maker will last for 12 Hrs. Tie all rafts together Use the mooring lines. Erect Canopy Luminous side to face upward (depend on the weather). 6. Emergency Communication ‘Attention Cabin Crew At ‘At altitude of 2000ft’ in a planned Emergency Stations’ landing Aborted take-off ‘Brace, Brace, Brace’ given by PM At 500ft above touch down (Just 20 Seconds before) ‘Cabin Crew & Passengers When there is no need for an Evacuation Remain seated’ ‘Evacuate, Evacuate, Evacuate’ & If Evacuation is required Press the EVAC command Switch ‘EMER CALL’ Switch button in the When ‘EMER CALL’ Initiated from Cabin to FLT overhead Panel & the ATT Lamp in Deck the Audio Control Panel Flashes in Amber along with the Three Long Buzzer in the FLT Deck A330 ‘EMER CALL’ Switch comes on Amber When ‘EMER CALL’ Initiated from FLT Deck to steady and Only the ATT Lamp in the Cabin Audio Control Panel Flashes in Amber A320 ‘EMER CALL’ Switch flashes both ways along with the ATT lamp in the Audio Control Panel 7. Other Important Information ▪ To release the slide raft from the door sill end in a ditching - raise the Velcro & pull the Release Tab. ▪ Crash Axe - Handle withstand 25,000 voltages ▪ Flash Light - Will last for 4 Hrs ▪ Heat resistance glows – withstand 1400 0C ▪ A10 Medical Kit - has a ‘BLUE SEAL’ ex-base (CMB) ▪ Lavatory waist bin fire extinguisher - activates at 72 0C ▪ Dragger PBE - can be used up to 15 Mts On ground checks - yellow seal inside not broken / seal on top is not broken / unit not touching the viewing window / box is not damage & in correct shape. ▪ Air liquid PBE - can be used up to 15 Mts On ground checks - seal on top is not broken / expiry date within 10 years / indicator green ▪ Infant life jackets A320 - 14 A321 - 16 A330 - 20 ▪ Kangaroo Belts A321 - 20 A320/330 - 20 ▪ The 03 Fire Fighting Personnel Fire Fighter / Communicator / Coordinator