National University College of Architecture Building Utilities 1 PDF
Document Details
National University - College of Architecture
Tags
Related
Summary
This document provides lecture notes on building utilities, specifically plumbing and sanitary systems. It covers various topics like sanitary drainage systems, vent piping systems, ventilation and ventilation systems, and plumbing traps, along with different plumbing terms.
Full Transcript
NATIONAL UNIVERSITY COLLEGE OF ARCHITECTURE Cluster Chair: AR. KAOLYNE GRACE C. HILARIO Cluster Heads AR. EMMARIE ROSE V. CRUZ AR. ANNIE C. PUGEDA Cluster Members AR. GENE LAMBERT R. GIRON AR. KA...
NATIONAL UNIVERSITY COLLEGE OF ARCHITECTURE Cluster Chair: AR. KAOLYNE GRACE C. HILARIO Cluster Heads AR. EMMARIE ROSE V. CRUZ AR. ANNIE C. PUGEDA Cluster Members AR. GENE LAMBERT R. GIRON AR. KAOLYNE GRACE C. HILARIO AR. ANNIE C. PUGEDA AR. VOLTAIRE V. VITUG ABUTLI1S: Building Utilities 1 PLUMBING & SANITARY SYSTEMS SANITARY DRAINAGE SYSTEMS VENT PIPING SYSTEMS VENTILATION AND VENTILATION SYSTEM PLUMBING TRAPS LEARNING OUTCOMES 1. Apply the fundamental concepts and principles, general design and installation of water supply, sanitary drainage systems, storm drainage system, waste disposal systems, and fire protection systems in building design consistent with trade practices and recommendations 2. Explain the importance of sanitation as well as plumbing in the context of building structures as a component of the overall building services function. PLUMBING TERMS (NPCP) VENT SYSTEM - pipes installed to provide flow of air to or from a drainage system or to provide a circulation of air within such system to protect traps seals from siphonage and backpressure MAIN VENT (VENT STACK) - principal artery of the venting system VENT STACK - vertical vent pipe installed primarily for providing a circulation of air STACK VENT - the extension of a soil or waste stack above the highest horizontal drain connected to the stack (SVTR) Two Principal Classifications of Vents 1. MAIN SOIL AND WASTE VENT (STACK VENT)/ SOIL STACK: the extension of a soil or waste stack above the highest horizontal drain connected to the stack (SVTR) 2. MAIN VENT (VENT STACK): principal artery, vertical vent pipe; “relief” and “yoke” vents; tributary; collecting vent line; relieves any back-pressure NPCP Chapter 2 Two Principal Classifications of Vents 1. MAIN SOIL AND WASTE VENT (STACK VENT)/ SOIL STACK 2. MAIN VENT (VENT STACK) WET VENT – that portion of a vent pipe through wastewater also flows through DRY VENT – a vent that does not carry liquid or water-borne wastes BRANCH VENT - a horizontal vent pipe connecting from a branch of the drainage system to a vent stack or stack vent GROUP VENT - a branch vent Section 901- VENTS REQUIRED Each plumbing fixture trap, except as otherwise provided in this Code, shall be protected against siphonage and back-pressure. Air circulation shall be assured throughout all parts of the excreta drainage system by means of vent pipes installed in accordance with the requirements of this Chapter and as required in this Code. PLUMBING TERMS (NPCP) INDIVIDUAL VENT: back vent; portion of the vent pipe system which serves a single trap UNIT VENT: portion of the vent pipe system which ventilates two fixture traps that discharge into a sanitary cross with deflectors CIRCUIT OR LOOP VENTILATION: portion of the drainage system which ventilates 2 or more fixture traps that discharge into a horizontal soil or waste branch extended at slight grade RELIEF VENTILATION: portion of the vent pipe installation which primarily eliminates minus and plus pressures in the drainage system; on long vertical pipes a relief vent, often referred to as yoke or by-pass vent maybe installed at 3 – 5 floor intervals LOOPED VENT: used on fixtures which are located in the room away from partitions that might be utilized to conceal the waste and vent. COMBINATION WASTE AND VENT SYSTEM - specially designed system of waste piping; horizontal wet venting of one or more sinks/floor drains by a common horizontal waste and vent pipe CONTINUOUS WASTE - drain connecting the compartments of a set of fixtures to a trap or connecting other permitted fixtures to a common trap LOCAL VENT: a conduit or pipe shaft used to convey the foul odours from a fixture or room; used to some extent in connection with water closets, connected to the fixture at a point below the seat; terminates at the roof UTILITY VENT: used for underground public restrooms PLUMBING TERMS (NPCP) VENT PIPE - a pipe or opening used for ensuring the circulation of air in a plumbing system; for reducing the pressure exerted on trap seals BACKVENT PIPE - connects directly with an individual trap underneath or behind the fixture INDIVIDUAL VENT - serves a single trap REVENT PIPE = backvent pipe PLUMBING TERMS (NPCP) COMMON VENT - (UNIT VENT/DUAL VENT) DUAL VENT - (UNIT VENT) UNIT VENT - an arrangement of venting so installed that one vent pipe will serve two traps PLUMBING TERMS (NPCP) 905.6 Two (2) fixtures may be served by a common vertical vent pipe when each such fixture wastes separately into an approved double branch fitting having inlet openings at the same level. PLUMBING TERMS (NPCP) CIRCUIT VENT - group vent from in front of the last fixture/connects to vent stack (LOOP VENT) LOOP OR CIRCUIT VENT – (extension is usually vertical immediately beyond its connection to the soil or waste pipe); connected to the stack vent PLUMBING TERMS (NPCP) RELIEF VENT – auxiliary vent (“yoke vent”) YOKE VENT - connecting upward from a soil or waste stack below the floor and below horizontal connection to an adjacent vent stack PLUMBING TERMS (NPCP) 907.1 Each soil or waste stack which extends ten (10) or more stories above the building drain shall be served by a parallel vent stack which shall extend undiminished in size from its upper terminal at the roof and connect to the soil or waste stack at ground level and at every fifth-floor levels with a "yoke vent" at a point below the horizontal soil or waste branch connection to the stack and at the nearby vent stack above the same floor to provide a relief vent. The size of yoke vent shall be not less in diameter than either the soil stack or the vent stack, whichever is smaller. PLUMBING TERMS (NPCP) LOOPED VENT: used on fixtures located in the room away from partitions that might be utilized to conceal the waste and vent. PLUMBING TERMS (NPCP) LOCAL VENT - pipe or shaft to convey foul air from a fixture or room to the outer air UTILITY VENT: underground PLUMBING TERMS (NPCP) COMBINATION WASTE AND VENT SYSTEM – horizontal wet venting of one or more sinks/floor drains by a common horizontal waste and vent pipe CONTINUOUS WASTE – drain connecting the compartments of a set of fixtures to a trap or connecting other permitted fixtures to a common trap Section 814- COMBINATION WASTE AND VENT SYSTEMS 814.1 Combination waste and vent systems (CW & VS) shall be permitted only where structural conditions preclude the installation of conventional systems as otherwise prescribed by this Code. NPCP. PLUMBING TERMS (NPCP) Where a conventional plumbing vent system is not available or not feasible the local plumbing inspector may permit an air admittance valve to be installed. The purpose of an air admittance valve is to provide a method of allowing air to enter the plumbing drainage system without the use of a vent extended to open air and to prevent sewer gases from escaping into a building. - UPC 2006 PLUMBING TERMS (NPCP) Chapter 10 Traps and Interceptors Section 1001 -TRAPS REQUIRED 1001.1 Each plumbing fixture, excepting those having integral traps, shall be separately trapped by an approved-type waterseal trap. Not more than one trap shall be permitted on a trap arm. 1001.2 It is provided, however, that one trap may serve a set of not more than three ( 3) single compartment sinks or laundry tubs of the same depth or three (3) lavatories immediately adjacent to each other and in the same room if the waste outlets are not more than 0.75 meter apart and the trap is centrally located when three (3) compartments are installed. The depth requirement may be waived if approved-type pump discharge the fixtures or appliances. 1001.3 No food waste disposal unit shall be installed on any set of restaurant, commercial or industrial sinks served by a single trap, each such food Waste disposal unit shall be connected to a separate trap. Each domestic clotheswasher and each laundry tub shall be connected to a separate and independent trap; except that a trap serving a laundry tub may also receive the waste from a clotheswasher set adjacent thereto. No clotheswasher or laundry tub shall be connected to any trap of a kitchen sink. 1001.4 The vertical distance between a fixture outlet and the trap weir shall be as short as practicable, but in no case shall the tailpiece from any fixture exceed 0. 6 meter in length. · PLUMBING TERMS (NPCP) TRAP - a fitting or device so constructed as to prevent the passage of air, gas SEAL - vertical distance between the dip and the crown weir of a trap/the water in the trap between the dip and the crown weir TRAP SEAL (WATER SEAL) - maximum vertical depth of liquid that a trap will retain, measured within the crown weir and the top of the dip of the trap Section 1005 - TRAP SEALS Each fixture trap shall have a water seal of not less than 51 mm and not more than 102 mm deep except where a deeper seal is found necessary by the Administrative Authority for special conditions. Traps shall be set erect and true with respect to their water seals. Two forms of water-sealed traps Types of Permissible Traps 1. P-Trap – ½ S 2. Drum Trap 3. Grease Trap Two forms of water-sealed traps Objectionable Traps/Non-Permissible Traps 1. Full S and ¾ S Traps 2. Bag Trap 3. Mechanically Sealed Trap 4. Internal Partition Trap 5. Light Metal Partition Traps (CLARIFIER) - intercept or to separate, and prevent the passage of oil, grease, sand CLARIFIER - (interceptor) GREASE INTERCEPTOR – interceptor of 3 cubic meters GREASE TRAP - retain grease from 1 - 4 fixtures (maximum) SAND INTERCEPTOR – (INTERCEPTOR) 1011.1 When, in the judgment of the Administrative Authority, Waste pretreatment is required, an approved-type grease trap complying with the provisions of this sections shall be installed in the wasteline leading from sinks, drains and other fixtures or equipment in establishments such as restaurants, cafes, lunch counters. cafeterias, bars and clubs, hotel hospital, sanitarium, factory or school kitchens, or other establishments where grease may be introduced into the drainage or sewer system in quantities that can effect line stoppage or hinder sewage treatment or private sewage disposal. A grease trap is not required for individual dwelling units or for any private living quarters. Drum traps do the same thing, but instead of just having a dip in the pipe to create a self-scouring P- trap, a drum trap consists of an enlarged 'vessel' that holds a large volume of water. Drum traps were commonly used at bathtubs and occasionally at laundry sinks. DOUBLE-BEND FITTING - fitting shaped like the “S” TRAP ARM - that portion of a fixture drain between a trap and the vent 1002.2 Each fixture trap shall have a protecting vent so located that the developed length of the trap and from the trap weir to the inner edge of the vent shall be within the distance given in Table 10-1, but in no case less than two times the diameter of the trap arm. 1002.3 A trap arm may change direction without the use of a cleanout when such change of direction does not exceed ninety (90) degrees. Section 1006- FLOOR DRAIN TRAPS Floor drain shall connect into a trap so constructed that it can be readily cleaned and of a size to serve efficiently the purpose for which it is intended. The drain inlet shall be so located that it is in all times in full view. When subject to reverse flow of sewage or liquid waste, such drains shall be equipped with an approved backwater valve. Section 1006- FLOOR DRAIN TRAPS Floor drain shall connect into a trap so constructed that it can be readily cleaned and of a size to serve efficiently the purpose for which it is intended. The drain inlet shall be so located that it is in all times in full view. When subject to reverse flow of sewage or liquid waste, such drains shall be equipped with an approved backwater valve. AIRBREAK - physical separation into indirect waste receptor from fixture, device indirectly connected AIR GAP, DRAINAGE - unobstructed vertical distance between the lowest opening from any pipe to the flood level rim of the receptor AIR GAP, WATER DISTRIBUTION - unobstructed vertical distance through free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood- level rim AIRBREAK/AIR GAP INDIRECT WASTE PIPE - a waste pipe that does not connect directly with the building drainage RECEPTOR - approved plumbing fixture/device to adequately receive discharge from indirect waste pipes SPECIAL WASTE - require special methods of handling (use of indirect waste piping and receptors, corrosion resistant piping, sand, oil or grease interceptors, condensers or other pre-treatment facilities 801.2 No cold storage room, refrigerator, cooling counter, compartment, receptacle, appurtenance or device used for the storage or holding of food or drink and no dishwashing or culinary sink in any food preparation room used for soaking, washing or preparing ready-to-serve food shall have any drain in connection therewith directly connected to any soil, waste or vent pipe. Such equipment or fixtures shall be drained by means of indirect waste pipes, as defined in Chapter 2 of this Code; and all wastes drained by them shall discharge through an airgap into an open floor sink or other approved type receptor properly connected to the drainage system. TOPIC for next meeting Storm Drainage Systems (surface and subsurface storm water) Roof catchment area, Gutter, Downspout, Catch Basins, Area Drains Read NPCP Chapter 11 – Storm Drainage System Roof catchment area, Gutter, Downspout, Catch Basins, Area Drains NPCP Chapter 11 – Storm Drainage System HOMEWORK No. 5 Research: Roof catchment area, Gutter, Downspout, Catch Basins, Area Drains REFERENCES NATIONAL PLUMBING CODE OF THE PHILIPPINES NATIONAL BUILDING CODE OF THE PHILIPPINES ILLUSTRATIONS (FROM GOOGLE)