This document details digital transmission concepts, including line coding, block coding, and its importance in communications. It explains the procedures and considerations.
Full Transcript
Chapter 4 Digital Transmission 4.1 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 4-1 DIGITAL-TO-DIGITAL CONVERSION In this section, we see how we can represent digital data by...
Chapter 4 Digital Transmission 4.1 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. 4-1 DIGITAL-TO-DIGITAL CONVERSION In this section, we see how we can represent digital data by using digital signals. The conversion involves three techniques: line coding, block coding, and scrambling. Line coding is always needed; block coding and scrambling may or may not be needed. cs discussed in this section: Line Coding Line Coding Schemes Block Coding Scrambling 4.2 Line Coding Converting a string of 1’s and 0’s (digital data) into a sequence of signals that denote the 1’s and 0’s. For example a high voltage level (+V) could represent a “1” and a low voltage level (0 or -V) could represent a “0”. 4.3 gure 4.1 Line coding and decoding 4.4 Mapping Data symbols onto Signal levels A data symbol (or element) can consist of a number of data bits: 1 , 0 or 11, 10, 01, …… A data symbol can be coded into a single signal element or multiple signal elements 1 -> +V, 0 -> -V 1 -> +V and -V, 0 -> -V and +V The ratio ‘r’ is the number of data elements carried by a signal element. 4.5 Relationship between data rate and signal rate The data rate defines the number of bits sent per sec - bps. It is often referred to the bit rate. The signal rate is the number of signal elements sent in a second and is measured in bauds. It is also referred to as the modulation rate. Goal is to increase the data rate whilst reducing the baud rate. 4.6 re 4.2 Signal element versus data element 4.7 Data rate and Baud rate The baud or signal rate can be expressed as: S = c x N x 1/r bauds where N is data rate c is the case factor (worst, best & avg.) r is the ratio between data element & signal element 4.8 Example 4.1 A signal is carrying data in which one data element is encoded as one signal element ( r = 1). If the bit rate is 100 kbps, what is the average value of the baud rate if c is between 0 and 1? Solution We assume that the average value of c is 1/2. The baud rate is then 4.9 Note Although the actual bandwidth of a digital signal is infinite, the effective bandwidth is finite. 4.10 Example 4.2 The maximum data rate of a channel (see Chapter 3) is Nmax = 2 × B × log2 L (defined by the Nyquist formula). Does this agree with the previous formula for Nmax? Solution A signal with L levels actually can carry log2L bits per level. If each level corresponds to one signal element and we assume the average case (c = 1/2), then we have 4.11 Considerations for choosing a good signal element referred to as line encoding Baseline wandering - a receiver will evaluate the average power of the received signal (called the baseline) and use that to determine the value of the incoming data elements. If the incoming signal does not vary over a long period of time, the baseline will drift and thus cause errors in detection of incoming data elements. A good line encoding scheme will prevent long runs of fixed amplitude. 4.12 Line encoding C/Cs DC components - when the voltage level remains constant for long periods of time, there is an increase in the low frequencies of the signal. Most channels are bandpass and may not support the low frequencies. This will require the removal of the dc component of a transmitted signal. 4.13 Line encoding C/Cs Self synchronization - the clocks at the sender and the receiver must have the same bit interval. If the receiver clock is faster or slower it will misinterpret the incoming bit stream. 4.14 re 4.3 Effect of lack of synchronization 4.15 Example 4.3 In a digital transmission, the receiver clock is 0.1 percent faster than the sender clock. How many extra bits per second does the receiver receive if the data Solution rate is 1 At 1kbps? How kbps, the manyreceives receiver if the 1001data rate ofis bps instead 1 1000 Mbps? bps. At 1 Mbps, the receiver receives 1,001,000 bps instead of 1,000,000 bps. 4.16 Line encoding C/Cs Error detection - errors occur during transmission due to line impairments. Some codes are constructed such that when an error occurs it can be detected. For example: a particular signal transition is not part of the code. When it occurs, the receiver will know that a symbol error has occurred. 4.17 Line encoding C/Cs Noise and interference - there are line encoding techniques that make the transmitted signal “immune” to noise and interference. This means that the signal cannot be corrupted, it is stronger than error detection. 4.18 Line encoding C/Cs Complexity - the more robust and resilient the code, the more complex it is to implement and the price is often paid in baud rate or required bandwidth. 4.19 igure 4.4 Line coding schemes 4.20 Unipolar All signal levels are on one side of the time axis - either above or below NRZ - Non Return to Zero scheme is an example of this code. The signal level does not return to zero during a symbol transmission. Scheme is prone to baseline wandering and DC components. It has no synchronization or any error detection. It is simple but costly in power consumption. 4.21 igure 4.5 Unipolar NRZ scheme 4.22 Polar - NRZ The voltages are on both sides of the time axis. Polar NRZ scheme can be implemented with two voltages. E.g. +V for 1 and -V for 0. There are two versions: NZR - Level (NRZ-L) - positive voltage for one symbol and negative for the other NRZ - Inversion (NRZ-I) - the change or lack of change in polarity determines the value of a symbol. E.g. a “1” symbol inverts the polarity a “0” does not. 4.23 gure 4.6 Polar NRZ-L and NRZ-I schemes 4.24 Note In NRZ-L the level of the voltage determines the value of the bit. In NRZ-I the inversion or the lack of inversion determines the value of the bit. 4.25 Note NRZ-L and NRZ-I both have an average signal rate of N/2 Bd. 4.26 Note NRZ-L and NRZ-I both have a DC component problem and baseline wandering, it is worse for NRZ- L. Both have no self synchronization &no error detection. Both are relatively simple to implement. 4.27 Example 4.4 A system is using NRZ-I to transfer 1- Mbps data. What are the average signal rate and minimum bandwidth? Solution The average signal rate is S= c x N x R = 1/2 x N x 1 = 500 kbaud. The minimum bandwidth for this average baud rate is Bmin = S = 500 kHz. Note c = 1/2 for the avg. case as worst case is 1 and best case is 0 4.28 Polar - RZ The Return to Zero (RZ) scheme uses three voltage values. +, 0, -. Each symbol has a transition in the middle. Either from high to zero or from low to zero. This scheme has more signal transitions (two per symbol) and therefore requires a wider bandwidth. No DC components or baseline wandering. Self synchronization - transition indicates symbol value. More complex as it uses three voltage level. It has no error detection capability. 4.29 igure 4.7 Polar RZ scheme 4.30 Polar - Biphase: Manchester and Differential Manchester Manchester coding consists of combining the NRZ-L and RZ schemes. Every symbol has a level transition in the middle: from high to low or low to high. Uses only two voltage levels. Differential Manchester coding consists of combining the NRZ-I and RZ schemes. Every symbol has a level transition in the middle. But the level at the beginning of the symbol is determined by the symbol value. One symbol causes a level change the other does not. 4.31 4.8 Polar biphase: Manchester and differential Manchester 4.32 Note In Manchester and differential Manchester encoding, the transition at the middle of the bit is used for synchronization. 4.33 Note The minimum bandwidth of Manchester and differential Manchester is 2 times that of NRZ. The is no DC component and no baseline wandering. None of these codes has error detection. 4.34 Bipolar - AMI and Pseudoternary Code uses 3 voltage levels: - +, 0, -, to represent the symbols (note not transitions to zero as in RZ). Voltage level for one symbol is at “0” and the other alternates between + & -. Bipolar Alternate Mark Inversion (AMI) - the “0” symbol is represented by zero voltage and the “1” symbol alternates between +V and -V. Pseudoternary is the reverse of AMI. 4.35 ure 4.9 Bipolar schemes: AMI and pseudoternary 4.36 Bipolar C/Cs It is a better alternative to NRZ. Has no DC component or baseline wandering. Has no self synchronization because long runs of “0”s results in no signal transitions. No error detection. 4.37 Multilevel Schemes In these schemes we increase the number of data bits per symbol thereby increasing the bit rate. Since we are dealing with binary data we only have 2 types of data element a 1 or a 0. We can combine the 2 data elements into a pattern of “m” elements to create “2m” symbols. If we have L signal levels, we can use “n” signal elements to create Ln signal elements. 4.38 Code C/Cs Now we have 2m symbols and Ln signals. If 2m > Ln then we cannot represent the data elements, we don’t have enough signals. If 2m = Ln then we have an exact mapping of one symbol on one signal. If 2m < Ln then we have more signals than symbols and we can choose the signals that are more distinct to represent the symbols and therefore have better noise immunity and error detection as some signals are not valid. 4.39 Note In mBnL schemes, a pattern of m data elements is encoded as a pattern of n signal elements in which 2m ≤ Ln. 4.40 Representing Multilevel Codes We use the notation mBnL, where m is the length of the binary pattern, B represents binary data, n represents the length of the signal pattern and L the number of levels. L = B binary, L = T for 3 ternary, L = Q for 4 quaternary. 4.41 gure 4.10 Multilevel: 2B1Q scheme 10,01,11,00,10 4.42 Redundancy In the 2B1Q scheme we have no redundancy and we see that a DC component is present. If we use a code with redundancy we can decide to use only “0” or “+” weighted codes (more +’s than -’s in the signal element) and invert any code that would create a DC component. E.g. ‘+00++-’ -> ‘-00--+’ Receiver will know when it receives a “-” weighted code that it should invert it as it doesn’t represent any valid symbol. 4.43 gure 4.11 Multilevel: 8B6T scheme 4.44 4.45 Multilevel using multiple In some cases,channels we split the signal transmission up and distribute it over several links. The separate segments are transmitted simultaneously. This reduces the signalling rate per link -> lower bandwidth. This requires all bits for a code to be stored. xD: means that we use ‘x’ links YYYz: We use ‘z’ levels of modulation where YYY represents the type of modulation (e.g. pulse ampl. mod. PAM). Codes are represented as: xD-YYYz 4.46 gure 4.12 Multilevel: 4D-PAM5 scheme 4.47 Multitransition Coding Because of synchronization requirements we force transitions. This can result in very high bandwidth requirements -> more transitions than are bits (e.g. mid bit transition with inversion). Codes can be created that are differential at the bit level forcing transitions at bit boundaries. This results in a bandwidth requirement that is equivalent to the bit rate. In some instances, the bandwidth requirement may even be lower, due to repetitive patterns resulting in a periodic signal. 4.48 gure 4.13 Multitransition: MLT-3 scheme 4.49 MLT-3 Signal rate is same as NRZ-I But because of the resulting bit pattern, we have a periodic signal for worst case bit pattern: 1111 This can be approximated as an analog signal a frequency 1/4 the bit rate! 4.50 ble 4.1 Summary of line coding schemes 4.51 Block Coding For a code to be capable of error detection, we need to add redundancy, i.e., extra bits to the data bits. Synchronization also requires redundancy - transitions are important in the signal flow and must occur frequently. Block coding is done in three steps: division, substitution and combination. It is distinguished from multilevel coding by use of the slash - xB/yB. The resulting bit stream prevents certain bit combinations that when used with line encoding would result in DC components or poor sync. quality. 4.52 Note Block coding is normally referred to as mB/nB coding; it replaces each m-bit group with an n-bit group. 4.53 gure 4.14 Block coding concept 4.54 e 4.15 Using block coding 4B/5B with NRZ-I line coding sche 4.55 ble 4.2 4B/5B mapping codes 4.56 re 4.16 Substitution in 4B/5B block coding 4.57 Redundancy A 4 bit data word can have 24 combinations. A 5 bit word can have 25=32 combinations. We therefore have 32 - 26 = 16 extra words. Some of the extra words are used for control/signalling purposes. 4.58 Example 4.5 We need to send data at a 1-Mbps rate. What is the minimum required bandwidth, using a combination of 4B/5B and NRZ-I or Manchester coding? Solution First 4B/5B block coding increases the bit rate to 1.25 Mbps. The minimum bandwidth using NRZ-I is N/2 or 625 kHz. The Manchester scheme needs a minimum bandwidth of 1.25 MHz. The first choice needs a lower bandwidth, but has a DC component problem; the second choice needs a higher bandwidth, but does not have a DC component problem. 4.59 gure 4.17 8B/10B block encoding 4.60 More bits - better error detection The 8B10B block code adds more redundant bits and can thereby choose code words that would prevent a long run of a voltage level that would cause DC components. 4.61 Scrambling The best code is one that does not increase the bandwidth for synchronization and has no DC components. Scrambling is a technique used to create a sequence of bits that has the required c/c’s for transmission - self clocking, no low frequencies, no wide bandwidth. It is implemented at the same time as encoding, the bit stream is created on the fly. It replaces ‘unfriendly’ runs of bits with a violation code that is easy to recognize and removes the unfriendly c/c. 4.62 gure 4.18 AMI used with scrambling 4.63 For example: B8ZS substitutes eight consecutive zeros with 000VB0VB. The V stands for violation, it violates the line encoding rule B stands for bipolar, it implements the bipolar line 4.64 encoding rule re 4.19 Two cases of B8ZS scrambling technique 4.65 HDB3 substitutes four consecutive zeros with 000V or B00V depending on the number of nonzero pulses after the last substitution. If # of non zero pulses is even the substitution is B00V to make total # of non zero pulse even. If # of non zero pulses is odd the substitution is 000V to make total # of non zero pulses even. 4.66 e 4.20 Different situations in HDB3 scrambling technique 4.67