SAK 254, Nitrate and Iron Test 1
30 Questions
1 Views
3.7 Stars

SAK 254, Nitrate and Iron Test 1

Created by
@SeasonedVibraphone

Questions and Answers

What is the designation for the spectral absorption coefficient measured at a wavelength of 254 nm?

SAK 254

What does the SAK 254 method help determine in water samples?

Dissolved organic contents

What must be done to the water sample before using the SAK 254 method for measurement?

Filtering

What is the pore size of the membrane filter required for filtering raw and drinking water for SAK 254 measurement?

<p>0.45 µm</p> Signup and view all the answers

At what wavelength is the measurement carried out photometrically in the SAK 254 method?

<p>$\lambda = 254$ nm</p> Signup and view all the answers

What does the spectral absorption coefficient at 254 nm characterize in water samples?

<p>Organic substances</p> Signup and view all the answers

What does the spectral attenuation coefficient µ  measured at a wavelength of 254 nm, represent?

<p>Sum of spectral absorption and scattered-coefficient at 254 nm</p> Signup and view all the answers

How is the light reduction in the water sample measured?

<p>By Lambert-Beer law</p> Signup and view all the answers

What is the significance of using a 0.45 µm filter during membrane filtration?

<p>To remove most contents in the water sample</p> Signup and view all the answers

What can cause false results in the measurements?

<p>All of the above</p> Signup and view all the answers

What is the dependence range suitable for measurements according to the text?

<p>$0.01 \text{ mol/L} &lt; \text{concentration} &lt; 2$</p> Signup and view all the answers

What does the corrected spectral attenuation coefficient measure?

<p>Stray-light corrected spectral attenuation coefficient at 254 nm</p> Signup and view all the answers

What is the measurement wavelength for the water sample with a spectrophotometer?

<p>$\lambda = 254$ nm</p> Signup and view all the answers

What is used to wash the quartz measuring cell?

<p>$2 \text{ mol/L}$ hydrochloric acid solution</p> Signup and view all the answers

What is used for membrane filtration?

<p>$0.45 \mu m$ syringe filter</p> Signup and view all the answers

What does the SAK 254 method help determine in water samples?

<p>Presence of dissolved organic substances</p> Signup and view all the answers

What is the significance of using a 0.45 µm filter during membrane filtration for SAK 254 measurement?

<p>To filter out dissolved organic substances for measurement</p> Signup and view all the answers

What is the designation for the spectral absorption coefficient measured at a wavelength of 254 nm?

<p>SAK 254</p> Signup and view all the answers

What must be done to the water sample before using the SAK 254 method for measurement?

<p>Filter the water sample with a 0.45 µm filter</p> Signup and view all the answers

What does the spectral absorption coefficient at 254 nm characterize in water samples?

<p>Presence of dissolved organic substances</p> Signup and view all the answers

What is used for membrane filtration before carrying out the SAK 254 measurement?

<p>0.45 µm membrane filter</p> Signup and view all the answers

What is the measurement wavelength for the water sample with a spectrophotometer?

<p>254 nm</p> Signup and view all the answers

What is the designation for the spectral absorption coefficient measured at a wavelength of 254 nm?

<p>α(λ)</p> Signup and view all the answers

What must be done to the water sample before using the SAK 254 method for measurement?

<p>Filtering with a 0.45 µm filter</p> Signup and view all the answers

What does the spectral attenuation coefficient µ  measured at a wavelength of 254 nm, represent?

<p>Sum of spectral absorption coefficient and spectral scattered-coefficient</p> Signup and view all the answers

What can cause false results in the measurements?

<p>Degassing oxygen or carbon dioxide</p> Signup and view all the answers

What is the significance of using a 0.45 µm filter during membrane filtration?

<p>To remove most contents in the water sample</p> Signup and view all the answers

What does the corrected spectral attenuation coefficient measure?

<p>Stray-light corrected spectral attenuation coefficient</p> Signup and view all the answers

What is used to wash the quartz measuring cell?

<p>Cell cleaning solution</p> Signup and view all the answers

What does the spectral absorption coefficient at 254 nm characterize in water samples?

<p>Spectral absorbance (extinction)</p> Signup and view all the answers

More Quizzes Like This

Water Analysis Quiz
10 questions

Water Analysis Quiz

CourteousSard9028 avatar
CourteousSard9028
Water Analysis and Classification
16 questions
28 Water Analysis MCQ2
10 questions

28 Water Analysis MCQ2

PrudentRainforest avatar
PrudentRainforest
Use Quizgecko on...
Browser
Browser