Wk 5 Knowledge Check (Edelman Ch 12-13) PDF
Document Details
CBD College
2024
Tags
Summary
This is a past knowledge check document from CBD College on ultrasound topics, specifically focusing on transducers and image formation. The document includes multiple choice questions.
Full Transcript
11/24/24, 11:52 AM WK 5: Knowledge Check (Edelman Ch 12-13): Attempt review | CBD College Started on Friday, 8 November 2024, 10:11 AM State Finished Completed on Friday, 8 November 2024, 10:15 AM T...
11/24/24, 11:52 AM WK 5: Knowledge Check (Edelman Ch 12-13): Attempt review | CBD College Started on Friday, 8 November 2024, 10:11 AM State Finished Completed on Friday, 8 November 2024, 10:15 AM Time taken 4 mins 45 secs Grade 10.00 out of 10.00 (100%) Question 1 Correct Mark 1.00 out of 1.00 Utilizing additional focal points causes the temporal resolution to __________. Select one: a. double b. improve c. degrade Additional focal points will cause a decrease in the temporal resolution (frame rate). d. remain unchanged Additional focal points will cause a decrease in the temporal resolution (frame rate). The correct answer is: degrade Question 2 Correct Mark 1.00 out of 1.00 A transducer with a small footprint is being used. What is a disadvantage to using this type? a. It cannot be focused in the elevational direction b. The Q value is very high c. The near field lateral resolution is poor d. Resolution is degraded at large distances e. The field of view in the far field is only one-quarter the diameter of the transducer The correct answer is: Resolution is degraded at large distances Help https://my.cbd.edu/mod/quiz/review.php?attempt=2721155&cmid=642670 1/4 11/24/24, 11:52 AM WK 5: Knowledge Check (Edelman Ch 12-13): Attempt review | CBD College Question 3 Correct Mark 1.00 out of 1.00 When voltage to the transducer elements is varied in order to reduce grating lobes, this is called Select one: demodulation compensation focusing apodization The correct answer is: apodization Question 4 Correct Mark 1.00 out of 1.00 Which of the following array transducers steers the beam mechanically? Select one: an annular phased a linear phased array a continuous wave a linear sequential array The correct answer is: an annular phased Question 5 Correct Mark 1.00 out of 1.00 If the depth of penetration is increased, the pulse repetition frequency (PRF) must be increased. Select one: a. True b. False Increasing imaging depth decreases the PRF and increases the pulse repetition period (PRP). Increasing imaging depth decreases the PRF and increases the pulse repetition period (PRP). The correct answer is: False https://my.cbd.edu/mod/quiz/review.php?attempt=2721155&cmid=642670 2/4 11/24/24, 11:52 AM WK 5: Knowledge Check (Edelman Ch 12-13): Attempt review | CBD College Question 6 Correct Mark 1.00 out of 1.00 What type of image format will a curvilinear sequential array transducer have? Select one: blunted sector trapezoid rectangular square The correct answer is: blunted sector Question 7 Correct Mark 1.00 out of 1.00 In relation to a mechanical transducer, if the imaging depth of a scan is 16 cm and there are 100 lines in the image, the number of pulses making up the scan is 1600. Select one: true false may be true or false, depending on transducer diameter The correct answer is: false Question 8 Correct Mark 1.00 out of 1.00 If one of the crystals in a linear switched array transducer is damaged, how will this affect the ultrasound image on the display? Select one: there will be an area of horizontal dropout there will be an area of vertical dropout no image will be present steering and focusing will be erratic The correct answer is: there will be an area of vertical dropout https://my.cbd.edu/mod/quiz/review.php?attempt=2721155&cmid=642670 3/4 11/24/24, 11:52 AM WK 5: Knowledge Check (Edelman Ch 12-13): Attempt review | CBD College Question 9 Correct Mark 1.00 out of 1.00 ___________ array is the combination of linear and phased array operations. Select one: a. Phased b. Convex c. Vector A vector array transducer uses a combination of both linear and phased array operations. It presents a sector display with a non-zero width at the top. d. Interventional A vector array transducer uses a combination of both linear and phased array operations. It presents a sector display with a non-zero width at the top. The correct answer is: Vector Question 10 Correct Mark 1.00 out of 1.00 With a phased array transducer, there are many active elements which are being fired at almost the same time. Select one: True False The correct answer is: True https://my.cbd.edu/mod/quiz/review.php?attempt=2721155&cmid=642670 4/4