🎧 New: AI-Generated Podcasts Turn your study notes into engaging audio conversations. Learn more

Topic Assessment 4 Protection Against Indirect Contact (60 min)_ Attempt review.pdf

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...

Document Details

SubsidizedImpressionism

Uploaded by SubsidizedImpressionism

TAFE

2024

Tags

electrical safety fault current protection systems

Full Transcript

26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Dashboard / My courses / EL03 - Arrange circuits, control and protection for electrical installations / Topic Assessments / Topic Assessment 4 Protection Aga...

26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Dashboard / My courses / EL03 - Arrange circuits, control and protection for electrical installations / Topic Assessments / Topic Assessment 4 Protection Against Indirect Contact (60 min) Started on Sunday, 11 August 2024, 5:45 PM State Finished Completed on Sunday, 11 August 2024, 5:47 PM Time taken 1 min 54 secs Marks 7.00/7.00 Grade 100.00 out of 100.00 Feedback Congratulations you have achieved 100%. Good luck with your continued studies. Question 1 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 1 Which of the following diagrams identifies indirect contact with live parts? Select one: a. (a) b. (d) c. (c) d. (b) Your answer is correct. https://learn.sydneytafe.edu.au/mod/quiz/review.php?attempt=1587986&cmid=1452018 1/6 26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Question 2 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 2 A Class 1 appliance on a final sub circuit develops an Active – Earth fault. From the following list, identify the circuit components that carry fault current in the “automatic disconnection of supply” method of protection against indirect contact. (Select FOUR) Select one or more: a. MEN link b. RCBO  c. Earth stake d. Final sub-circuit Protective Earth Conductor e. Main earth f. Consumer Main PEN conductor g. Final sub-circuit neutral conductor Your answer is correct. https://learn.sydneytafe.edu.au/mod/quiz/review.php?attempt=1587986&cmid=1452018 2/6 26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Question 3 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 3 The touch voltage will appear across points: Select one: a. c - i b. b - c c. e - f d. a - f Your answer is correct. https://learn.sydneytafe.edu.au/mod/quiz/review.php?attempt=1587986&cmid=1452018 3/6 26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Question 4 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 4 Select FIVE points where the touch current through the person will flow in the circuit. Select one or more: a. h - e b. a - f c. c - i d. i - h e. b - c f. c-e Your answer is correct. https://learn.sydneytafe.edu.au/mod/quiz/review.php?attempt=1587986&cmid=1452018 4/6 26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Question 5 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 5 Select FOUR points where the fault current will flow. Select one or more: a. b - c b. a - b c. e - f d. c - e e. c - d Your answer is correct. https://learn.sydneytafe.edu.au/mod/quiz/review.php?attempt=1587986&cmid=1452018 5/6 26/08/2024, 22:59 Topic Assessment 4 Protection Against Indirect Contact (60 min): Attempt review Question 6 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 6 In a domestic installation the following final subcircuits must be provided with RCD protection: (Select ONE) Select one: a. All final subcircuits b. Light and power c. Power d. Light Your answer is correct. Question 7 Correct Mark 1.00 out of 1.00 Topic Assessment 4 Protection Against Indirect Contact Question 7 AS/NZS 3000: 2018 outlines protection requirements for damp situations in four zones. Electrical equipment permitted to be installed in Zones 1 and 2 shall have at the least what degree of protection? Select one: a. IPX2 b. IPX7 c. IPX5 in communal baths/showers; IPX4 in other locations d. IPX6 Your answer is correct. ◀︎Topic Assessment 3 Hazards and Risks in an Electrical Installation (60 min) Jump to... Topic Assessment 5 Earthing (60 min) ▶︎ https://learn.sydneytafe.edu.au/mod/quiz/review.php?attempt=1587986&cmid=1452018 6/6

Use Quizgecko on...
Browser
Browser