Ludlum Model 44-2 Gamma Scintillator PDF 2018

Document Details

ValiantSunstone

Uploaded by ValiantSunstone

2018

Tags

gamma scintillator radiation detector nuclear instrumentation technical manual

Summary

This document is a technical manual for the Ludlum Model 44-2 Gamma Scintillator, providing detailed information about specifications, operating procedures, safety considerations, and parts lists for the device. It was published in February 2018.

Full Transcript

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MEASUREMENTS, IN...

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MODEL 44-2 GAMMA SCINTILLATOR February 2018 Serial Number PR361009 and Succeeding Serial Numbers LUDLUM MEASUREMENTS, INC. 501 OAK STREET, P.O. BOX 810 SWEETWATER, TEXAS 79556 325-235-5494, FAX: 325-235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered in this manual to be free of defects due to workmanship, material, and design for a period of twelve months from the date of delivery. The calibration of a product is warranted to be within its specified accuracy limits at the time of shipment. In the event of instrument failure, notify Ludlum Measurements to determine if repair, recalibration, or replacement is required. This warranty excludes the replacement of photomultiplier tubes, G-M and proportional tubes, and scintillation crystals which are broken due to excessive physical abuse or used for purposes other than intended. There are no warranties, express or implied, including without limitation any implied warranty of merchantability or fitness, which extend beyond the description of the face there of. If the product does not perform as warranted herein, purchaser’s sole remedy shall be repair or replacement, at the option of Ludlum Measurements. In no event will Ludlum Measurements be liable for damages, lost revenue, lost wages, or any other incidental or consequential damages, arising from the purchase, use, or inability to use product. RETURN OF GOODS TO MANUFACTURER If equipment needs to be returned to Ludlum Measurements, Inc. for repair or calibration, please send to the address below. All shipments should include documentation containing return shipping address, customer name, telephone number, description of service requested, and all other necessary information. Your cooperation will expedite the return of your equipment. LUDLUM MEASUREMENTS, INC. ATTN: REPAIR DEPARTMENT 501 OAK STREET SWEETWATER, TX 79556 800-622-0828 325-235-5494 FAX 325-235-4672 Table of Contents Introduction 1 Unpacking and Repacking 2 Specifications 3 Operating Procedures 4 Safety Considerations 5 Parts List, Drawings and Diagrams 6 Energy Response Curve 10 Ludlum Measurements, Inc. February 2018 Model 44-2 Gamma Scintillator Introduction The Model 44-2 sodium iodide (NaI) gamma scintillator is primarily used for detecting low levels of gamma radiation in the range of 20 keV–1.5 MeV. It consists of a 2.54 x 2.54 cm (1 x 1 in.) (Dia. X thickness) NaI crystal coupled to a photomultiplier tube and is housed in a 0.157 cm (0.062 in.) thick aluminum housing. The front entrance window has a total thickness of 2.3 mm (0.09 in.) of aluminum. The detector is energy dependent, over-responding by a factor of 10 or greater in the 100keV range and under-responding by a factor of 0.5 above 1 MeV when normalized to 137Cs. The Model 44-2 will operate with any Ludlum instruments or equivalent instruments that provide 500–1200 volts. The recommended instrument input sensitivity is approximately 10 mV or higher. Some common applications for this detector include background radiation monitoring, low-level radiation detection, and spectrum analysis when used in conjunction with a single- or multi-channel analyzer. Model 44-2 Note: The detector does not contain any consumable materials. Ludlum Measurements, Inc. Page 1 February 2018 Model 44-2 Gamma Scintillator Note: If the detector is used in a manner not intended by the manufacturer, the detector may not function properly. Unpacking and Repacking Remove the calibration certificate or detector functional check certificate and place it in a secure location. Remove the detector(s) and accessories (if applicable) and ensure that all items listed on the packing list are in the carton. If multiple detectors are included, refer to the calibration certificates for serial number (SN) matches. To return an instrument or detector for repair or calibration, provide sufficient packing material to prevent damage during shipment, and affix appropriate warning labels to promote careful handling. Every returned instrument must be accompanied by an Instrument Return Form, which can be downloaded from the Ludlum website at www.ludlums.com. Find the form by clicking the “Support” tab and selecting “Repair and Calibration” from the drop-down menu. Then choose the appropriate Repair and Calibration division where you will find a link to the form. Ludlum Measurements, Inc. Page 2 February 2018 Model 44-2 Gamma Scintillator Specifications Compatible Instruments: general-purpose survey meters, ratemeters and scalers Sensitivity: typically 175 cpm per µR/hr (137 Cs gamma) Dead Time: approximately 10 µs, typically limits linear range to 5 mR/hr (50 µSv/h) with non-corrected measurements, or to 50 mR/hr (500 µSv/h) with electronics equipped with dead time correction Energy Response: energy dependent Background: 1800 cpm Operating Voltage: 500–1200 volts Dynode String Resistance: 100 megohm Connector: series ˝C˝ (others available) Scintillator: 2.5 x 2.5 cm (1 x 1 in.) Dia. x thickness) Tube: 2.9 cm (1.1 in.) diameter magnetically shielded photomultiplier 125 Efficiency (4 π): I is 7%; 57Co is 10%; 137Cs is 3%; 60Co is 3% Construction: aluminum housing with beige powder-coat finish Temperature Range: -15 to 50 °C (5 to 122 °F); may be certified for -40 to 65 °C (-40 to 150 °F) Size: 5.1 x 18.5 cm (2 x 7.3 in.) (Dia. x L) Weight: 0.5 kg (1 lb) Ludlum Measurements, Inc. Page 3 February 2018 Model 44-2 Gamma Scintillator Operating Procedures CONNECTING TO AN INSTRUMENT Connect one end of the cable provided to the detector by firmly pushing the connector together while twisting clockwise one quarter of a turn until latched. Repeat the process in the same manner with the other end of the cable and the instrument. TESTING THE DETECTOR 1. Ensure the instrument high voltage (HV) is at the proper setting for the detector. 2. Connect the detector to the instrument and check for a proper background reading (typically 1.4-2.6 kcpm or 8- 15 µR/hr). 3. Expose the detector to a check source and verify that the instrument indicates within 20% of the check source reading from the last calibration. Alternatively, expose the detector to a source of known value and verify that the detector detects greater than or equal to the efficiency listed in the specification section of this manual. 4. Instruments and detectors that meet these criteria are ready for use. Failure to meet these criteria may indicate a malfunction in the detector. Ludlum Measurements, Inc. Page 4 February 2018 Model 44-2 Gamma Scintillator Safety Considerations ENVIRONMENTAL CONDITIONS FOR NORMAL USE 1. Indoor or outdoor use (in a dry environment) 2. No maximum altitude 3. Temperature range of -20 to 50 °C (5 to 122 °F); May be certified for operation from -40 to 65 °C (-40 to 150 °F). 4. Maximum relative humidity of less than 95% (non- condensing) 5. Pollution Degree 3 (as defined by IEC 664) (Occurs when conductive pollution or dry nonconductive pollution becomes conductive due to condensation. This is typical of industrial or construction sites.) CLEANING INSTRUCTIONS AND PRECAUTIONS The detector may be cleaned externally with a damp cloth, using only water as the wetting agent. Do not immerse the instrument in any liquid. Observe the following precautions when cleaning: 1. Turn the instrument electronics OFF. 2. Allow the instrument to sit for one minute. 3. Disconnect the detector cable before cleaning the detector. Ludlum Measurements, Inc. Page 5 February 2018 Model 44-2 Gamma Scintillator Parts List, Drawings and Diagrams Model 44-2 Gamma Scintillator Reference Description Part Number UNIT Completely Assembled Model 44-2 Alpha-Beta-Gamma Detector 47-1532 1 EA DETECTOR BODY 2002-084-01 1 EA END CAP 7002-505 1 EA 2.5 x 2.5 cm (1 x 1 in.) NaI CRYSTAL 40-5154 1 EA 1.125 in. TUBE SOCKET ASSY 01-5742 1 EA TUBE SHIELD 40-4006 1 EA CONNECTOR, UG 706/U 4478-011 1 EA EJ560-1.10 ×.080 OPT PAD 01-5786 ** FOAM 14-5873 1 EA O-RING 16-8317 4 EA SCREWS 17-8811 1 EA LUG 18-8766 8 EA SPONGE 7002-029-05 1 EA SPONGE 4-P BS 7002-065-04 11.4 cm (4.5 in.) TEFLON WIRE 21-8993 11.4 cm (4.5 in.) # 24 WIRE 21-9558 Ludlum Measurements, Inc. Page 6 February 2018 Model 44-2 Gamma Scintillator Ludlum Measurements, Inc. Page 7 February 2018 Model 44-2 Gamma Scintillator Reference Description Part Number 3.8 cm (1.5 in.) Tube Socket Board 1 EA CIRCUIT BOARD 5002-370 1 EA CAP 0.01 µF 2kv 04-5525 11 EA RES 10 M, ¼ W, 1% 12-7996 1 EA RES 1 M, ¼ W, 1% 12-7844 Ludlum Measurements, Inc. Page 8 February 2018 Model 44-2 Gamma Scintillator 3.8 cm (1.5 in.) Tube Socket Board - Schematic Ludlum Measurements, Inc. Page 9 February 2018 Ludlum Measurements, Inc. Page 10 February 2018

Use Quizgecko on...
Browser
Browser