Induction - Basic Engineer Theory 2024 PDF

Summary

This Biznet document details the 2024 Basic Engineer Theory induction program, covering various aspects of their fiber optic network infrastructure, including FTTH and Metro-E technologies. It also outlines job descriptions, workflows, and safety procedures.

Full Transcript

BASIC ENGINEER THEORY 2024 Training Department | Ext. 1761/1762 [email protected] Biznet Confidential Documentation This document is provided for information purposes only. The contents, including any views expressed by Biznet are indicative only and subject to change. This document is sub...

BASIC ENGINEER THEORY 2024 Training Department | Ext. 1761/1762 [email protected] Biznet Confidential Documentation This document is provided for information purposes only. The contents, including any views expressed by Biznet are indicative only and subject to change. This document is subject to the information classification set out on each page. If no information classification has been included, this document must be Confidential treated as Confidential Document Documentation and must not be disclosed other than with the consent of Biznet. © 2000 – 2024 Biznet. Biznet Home, Biznet IPTV, Biznet Metronet and other Biznet related product/services are trade marks of Biznet. All rights reserved. Ground Rules / Aturan Dasar Pelatihan No Sounds No Talking No Handphone On Time Confidence No Sleeping Just do it Confidential Documentation Target Pelatihan Target Pelatihan S P Confidential Documentation Agenda Agenda 1. Infrastructure FTTH 2. Infrastructure METRO-E 3. Job Description Engineer 4. Workflow Engineer 5. Safety Working at Height Confidential Documentation The New Biznet Fiber Network Confidential Documentation The New Biznet Fiber Network The New Biznet Fiber merupakan jaringan fiber terbaru yang didukung oleh teknologi yang canggih dan andal. Menawarkan layanan Internet dengan performa terbaik dan kapasitas yang jauh lebih besar, jaringan fiber terbaru akan menjawab tantangan di masa depan. The New Biznet Fiber menawarkan pilihan layanan Internet terbaik untuk mendukung kebutuhan usaha maupun pribadi, menjawab tantangan yang semakin beragam. #PakeBiznet Lebih Cepat! Confidential Documentation The New Biznet Fiber Network Metro Ethernet GPON – FTTX 10G/100G Network (Gigabit Passive Optical Network) Based on Metro Ethernet Network technology Based on full protection network with Ring topology, providing auto protection and Full Fiber to customer location. during a cut in Fiber Optic Backbone. Link between SuperPOP & InterCity POP Based on GPON (Gigabit Passive Optical minimum 100 Gbps. Network) network access that can deliver services up to 2,5 Gbps. Using the latest ONT (Optical Network Terminal) International Bandwidth Capacity 400 Gbps modem device including the latest Wi-Fi technology with higher and faster data transfer. Confidential Documentation Biznet Fiber Indonesia | 2,800 | 6,900 Kelurahan Gedung & Apartment Legend Existing Route Plan Route 2022 / 2026 Under Construction Biznet Submarine Cable Plan Biznet Submarine Cable Existing Biznet Data Center Biznet Submarine Cable Landing Station © 2022 - 12 Biznet. All rights reserved. Confidential Documentation Biznet Fiber Java Bali Menghubungkan 180+ kota yang menjangkau lebih dari 180 juta jiwa Legend Existing Route Plan Route 2022 / 2026 Under Construction Biznet Submarine Cable Plan Biznet Submarine Cable Existing Biznet Data Center Biznet Submarine Cable Landing Station © 2022 - 12 Biznet. All rights reserved. Confidential Documentation Biznet Fiber Sumatra | Kalimantan Sulawesi | Nusa Tenggara Timur Koneksi backbone ke Hub Singapore dengan kapasitas 1.6 Tbps dan multiple routes Legend Existing Route Plan Route 2022 / 2026 Under Construction Biznet Submarine Cable Plan Biznet Submarine Cable Existing Biznet Data Center Biznet Submarine Cable Landing Station © 2022 - 12 Biznet. All rights reserved. Confidential Documentation Biznet Infrastructure FTTH Confidential Documentation Infrastructure FTTH FTTH dapat didefinisikan sebagai arsitektur jaringan optik mulai dari Super POP (SPOP) hingga ke perangkat pelanggan Confidential Documentation Infrastructure (FTTH) SFP C+ PE Router OLT Confidential Documentation Infrastructure (FTTH) SFP C++ PE Router OLT Confidential Documentation Perangkat FTTH Confidential Documentation Fiber Optic Cable Berikut kabel yang digunakan di Biznet: 1. Kabel Drop Core (Segmen Akses) 2. Kabel 12 Core (2 Tube) 3. Kabel 24 Core (4 Tube) 4. Kabel 48 Core (8 Tube) 5. Kabel 84 Core (14 Tube) 6. Kabel 96 Core (8 Tube) 7. Kabel 144 Core (12 Tube) 8. Kabel 216 Core (18 Tube) Confidential Documentation OLT (Optical Line Terminal) Mini OLT Terdiri 2 Slot GPON Card, sedangkan OLT terdiri dari 14 & 16 slot GPON Card OLT - HUAWEI MA5600T 1 Port SFP GPON C++ mampu menampung hingga 128 customer dengan power +7 dBm 1 Port SFP GPON B/W yang diperoleh: OLT to ONT 2.5 Gbps ONT to OLT 1.25 Gbps Mini OLT - HUAWEI MA5608T Confidential Documentation SFP (Small Form-factor Plugable) SFP adalah perangkat yang men-transmitte dan me-receive sinyal informasi dengan media serat optic. SFP (Small Form-factor Plugable) Confidential Documentation Labeling OLT GPON (Mini & Big) Frame / Slot / Port Mini OLT - HUAWEI MA5608T OLT - HUAWEI MA5600T Confidential Documentation OTB adalah perangkat yang digunakan untuk menyambungkan OTB kabel backbone dengan patchcord power dari OLT (Optical Terminal Box) OTB yang digunakan Biznet adalah OTB dengan adaptor LC dengan jumlah 24 port dalam 1 cassete Confidential Documentation Rumah Kabel (RK) Rumah kabel adalah perangkat yang digunakan untuk menyambungkan kabel backbone dari arah SPOP dengan kabel distribusi yang selanjutnya akan di pecah menggunakan splitter menuju ke arah DP Terdapat 3 Tipe RK, yaitu: RK 144 Ground Mounting RK 144 Pole Mounting RK 384 RK 576 Terdapat 2 jenis splitter yang digunakan di dalam RK, yaitu: Splitter 1:8 untuk infrastructure Aerial Splitter 1:16 untuk infrastructure Ducting Confidential Documentation DP Aerial DP Ducting DP Building DP adalah perangkat dimana kabel input dari arah RK akan di pecah menggunakan DP splitter yang akan disambungkan dengan kabel ke arah customer DP terbagi menjadi 3 Jenis: (Distribution Point) DP HTSC 135 (Splitter 1:8) untuk infrastructure Ducting DP HTSC 136 (Splitter 1:16) untuk infrastructure Aerial DP Sunsea (Splitter 1:32 atau 1:64) untuk Building Confidential Documentation Urutan Port Splitter di DP Confidential Documentation ONT (Optical Network Terminal) HUAWEI - EG8245H5 HUAWEI - EG8145V5 2,4 GHz 2,4 GHz & 5 GHz Confidential Documentation 2.4 GHz 5 GHz KEUNTUNGAN KEUNTUNGAN Cakupan area lebih luas Kecepatan transfer lebih cepat Penetrasi obyek solid lebih baik Lebih aman terhadap interferensi KEKURANGAN KEKURANGAN Rentan terhadap interferensi Cakupan area yang lebih sempit Kecepatan lebih lambat dibandingkan 5 GHz Sulit menembus material padat Confidential Documentation Questions? Confidential Documentation Power Link Budget Confidential Documentation Power Link Budget FAKTOR REDAMAN Loss FO Splitter 1:2 = 4 db Loss FO Splitter 1:4 = 7 db Loss FO Splitter 1:8 = 10 db Loss FO Splitter 1:16 = 14 db Loss FO Cable (G 652 D) = 0.37 db / km Loss Sambungan Fusion Splicer = 0.02 dB Power Transmit OLT GPON 64 Based = +3 dBm Power Transmit OLT GPON 128 Based = +7 dBm Receive Sensitivity ONT GPON = -27 dBm Jarak Maksimal SPOP – Customer = 15 km Confidential Documentation Power Link Budget Confidential Documentation Power Link Budget L = Panjang | Panjang kabel dari OLT – ONT, standard disini 15 km Pr = Power Received , Pt = Power Transmited Perhitungan 1 line FTTH GPON C++ Aerial dari OLT - ONT dengan Power OLT 5 dBm dan terdapat total sambungan sebesar 2db Pr = Pt – Loss Pr = Pt – (Loss Cable + Loss Splitter + Sambungan) Pr = Pt – (L x 0,37db + Loss Splitter 1:8 + Loss Splitter 1:16 + Sambungan) = +5 dBm – (15 x 0.37 + 10 + 14 + 2) db = +5 dBm – (31,55 dB) Pr = -26,55 dBm Confidential Documentation Power Link Budget Kesimpulan dari Power Link Budget: 1. Dengan Pr > Receive Sensitivity ONT , sehingga dengan Jarak max 15 km jarigan FTTH kita masih acceptable 2. FTTH adalah project sambungan FO, sehingga sambungan akan menjadi perhatian kita dalam operationalnya, apalagi dengan sambungan Adapter FO. Bisa dilihat Loss Adapter FO > 0.2 db. Jika dibandingkan dengan Loss cable FO yang hanya 0.37 db/km, pengguanan adapter yang banyak tanpa dilakukan maintenance akan menjadi masalah di kemudian hari. Confidential Documentation Questions? Confidential Documentation Biznet Infrastructure Metro-E Confidential Documentation Infrastructure (Metro Ethernet) Metro Ethernet adalah Jaringan Metro Ethernet, secara harfiah berarti jaringan komunikasi data yang berskala metro (skala untuk menjangkau satu kota besar seperti Jakarta) dengan menggunakan teknologi Ethernet sebagai protokol transportasi datanya Confidential Documentation Perangkat Aktif HUAWEI ATN 910 C-B / C-G SFP (Small Form-factor Plugable) adalah perangkat yang men-transmitte dan me-receive sinyal informasi dengan media serat optic. Confidential Documentation JENIS SFP (ER & LR) Interconnect AKA Data Rate Wavelength Fiber Mode Max range Connector Medium Short 10GBASE-SR 10.3125Gbit/s 850nm 300m X2,SFP+ wavelength, Serial Multimode Fiber short reach Long Serial Singlemode 10km 10GBASE-LR wavelength, 10.3125Gbit/s 1310nm XENPAK,X2,XFP,SFP+ Fiber long reach 10GBASE- Long 1310nm LRM wavelength 10.3125Gbit/s Serial Multimode 220m XENPAK,X2,SFP+ Fiber multi-mode 10GBASE-ER Extra long XENPAK,X2,XFP,SFP+ 10.3125Gbit/s 1550nm Serial Singlemode 40km Fiber wavelength 80km Fiber 10GBASE-ZR 10.3125Gbit/s 1550nm Serial Singlemode XENPAK,X2,XFP,SFP+ Confidential Documentation Huawei ATN 910C – Product Appearance Confidential Documentation Huawei ATN 910C – Product Appearance HUAWEI ATN 910 C-G (METRO-E) XGE/GE/FE GE/FE Confidential Documentation Ketentuan Pembangunan Backbone dan Metro-E Ketentuan yang akan di implementasi 1 Ring – Maksimal 8 gedung terkoneksi (Huawei ATN 910 C-B/ C-G) Tube 1 digunakan untuk PE antar SPOP Tube 2 digunakan untuk RING Untuk Nortel (Metro-E) dan Brocade (Metro-E) akan dimigrasi ke Huawei secara bertahap. HUAWEI ATN 910 C-G (METRO-E) Confidential Documentation Ketentuan untuk Infrastruktur pada Gedung/Building Direct Core OLT – Digunakan untuk < 200 Homepass ATN 910 C-B / 910 C-G – Digunakan untuk single tenant / interconnection ATN + GPON Infrastructure – Digunakan untuk > 200 HP / 8 Floor Building / 15.000.000 Single Tenant HUAWEI ATN 910 C-B (METRO-E) HUAWEI SmartAX EA5801-GP08 (GPON) Confidential Documentation Instalasi Gedung - Direct Core OLT (Plaza Residence) Confidential Documentation Instalasi Gedung - Mini OLT (Apartemen Metro Sunter) Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT Pembangunan Metro-E + Mini-OLT harus menyesuaikan homepass maksimal dari suatu Gedung. Building 512 Homepass OLT SmartAX EA5801-GP08 with SFP C+ Building 1024 Homepass OLT MA5608T with SFP C+ Building 2048 Homepass OLT MA5608T with SFP C++ METRO-E + GPON Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT Instalasi gedung dengan ketentuan Metro-E + Mini-OLT menggunakan beberapa topologi yaitu (SFP C+). Topologi 1x8 – 1x8 Topologi 1x4 - 1x16 Topologi 1x2 - 1x32 Topologi 1x64 Masing-masing topologi dapat digunakan sesuai dengan syarat dan ketentuan dari pihak gedung. METRO-E + GPON Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT Instalasi gedung dengan ketentuan Metro-E + Mini-OLT menggunakan beberapa topologi yaitu (SFP C++). Topologi 1x16 – 1x8 Topologi 1x8 - 1x16 Topologi 1x4 - 1x32 Topologi 1x2 - 1x64 Masing-masing topologi dapat digunakan sesuai dengan syarat dan ketentuan dari pihak gedung. METRO-E + GPON Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT (1x8) Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT (1x16) Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT (1x32) (Template) Confidential Documentation Instalasi Gedung - Metro-E + Mini OLT (1x64) (Template) Confidential Documentation Questions? Confidential Documentation Jobdesc Engineer Confidential Documentation Job Description Network Operation (Access, Distribution, Backbone) Responsible to handling and solve technical problem on Biznet Networks Bertanggung jawab untuk mengatasi masalah teknis pada jaringan Biznet Confidential Documentation Job Description Network Operation Access Responsible to deliver Biznet Internet Services and to handling technical problem on Access Networks (Customers) Bertanggung jawab untuk memberikan layanan internet Biznet dan mengatasi masalah teknis pada segment akses Biznet Confidential Documentation Job Description Network Operation Distribution Responsible to handling and solve technical problem on Distribution Networks Bertanggung jawab untuk mengatasi masalah teknis pada jaringan distribusi Biznet Confidential Documentation Job Description Network Operation Backbone Responsible to handling and solve technical problem on Backbone Networks Bertanggung jawab untuk mengatasi masalah teknis pada jaringan backbone Biznet Confidential Documentation Job Description Project Engineer Design and construct Biznet Fiber Optic Merancang dan membangun jaringan Fiber Optik Biznet Confidential Documentation Job Description Network Assurance Audit Biznet infrastructure Memeriksa jaringan infrastruktur Biznet Confidential Documentation Questions? Confidential Documentation Workflow Engineer Confidential Documentation Workflow Access Engineer (Installer) PSSI-API Persiapan – Salam – Survey – Instalasi – Aktivasi – Penutup – Informasi Confidential Documentation Workflow Access Engineer (Installer) Persiapan APD (Alat Pelindung Diri) Dokumen (WO, STNK, SIM) Tools & Material Kendaraan Grooming Confidential Documentation Workflow Access Engineer (Installer) Salam Perkenalkan diri Anda Beritahu maksud kedatangan Anda Konfirmasi alamat customer dan pilihan layanan Meminta Izin sebelum masuk ke rumah Confidential Documentation Workflow Access Engineer (Installer) Survey Survey Penempatan ONT Survey Jalur kabel dari DP hingga ONT di dalam rumah customer Pastikan hasil survey sesuai dengan SOP yang berlaku di Biznet Confidential Documentation Workflow Access Engineer (Installer) Instalasi Pastikan instalasi sesuai dengan keinginan pelanggan dan SOP Biznet Menjaga kebersihan dan kerapihan area instalasi Confidential Documentation Workflow Access Engineer (Installer) Aktivasi Pastikan internet dapat dijalankan dengan baik sesuai paket Persilahkan customer untuk mencoba layanan yang sudah di aktivasi Confidential Documentation Workflow Access Engineer (Installer) Penutup & Informasi Pastikan segala form dan dokumen di tanda tangan pelanggan Berpamitan dan memberikan informasi yang dapat mengedukasikan pelanggan Confidential Documentation Workflow Access Engineer (Troubleshoot) PSP-MPI Persiapan – Salam – Pengecekan – Monitoring – Penutup – Informasi Confidential Documentation Workflow Access Engineer (Troubleshoot) Persiapan APD (Alat Pelindung Diri) Dokumen (WO, STNK, SIM) Tools & Material Kendaraan Grooming Confidential Documentation Workflow Access Engineer (Troubleshoot) Salam Perkenalkan diri Anda Beritahu maksud kedatangan Anda Konfirmasi alamat customer dan kendala yang dialami customer Meminta Izin sebelum masuk ke rumah Confidential Documentation Workflow Access Engineer (Troubleshoot) Pengecekan Pengecekan dan perbaikan masalah pelanggan Memberikan saran yang solutif Pastikan troubleshoot sesuai dengan keinginan pelanggan dan SOP Biznet Menjaga kebersihan dan kerapihan area pelanggan Confidential Documentation Workflow Access Engineer (Troubleshoot) Monitoring Lakukan monitoring kurang lebih 30 menit Monitoring perlu dilakukan untuk memastikan bahwa koneksi internet problem tidak terulang kembali di kemudian hari. Confidential Documentation Workflow Access Engineer (Troubleshoot) Penutup & Informasi Informasikan ke customer terkait dengan kendala yang terjadi. Saring informasi yang seharusnya, mana informasi yang menjadi konsumsi pelanggan, mana informasi yang tidak perlu kita sampaikan kepada pelanggan. Pastikan segala form dan dokumen di tanda tangan pelanggan Confidential Documentation Flowchart Troubleshoot FTTH Confidential Documentation Workflow Distribution Engineer FTTH (DISTRIBUTION) LOSS Confidential Documentation Troubleshooting Distribusi FTTH (Loss) Langkah awal troubleshoot yang pertama di lakukan adalah cek input DP yang terkendala. Apabila hasil pengecekan input DP Loss, pengecekan dilanjutkan dengan melakukan pengukuran (OTDR) kearah RK, terlihat dari hasil pengukuran terdapat titik cut di jarak sesuai hasil ukuran. Confidential Documentation Troubleshooting Distribusi FTTH (Loss) Koordinasi ke Dipatcher prihal Datek (data teknis) infrastruktur FTTH sesuai daerah mana yang terkendala, untuk keperluan tracing titik cut. Confidential Documentation Troubleshooting Distribusi FTTH (Loss) Tim menuju lokasi/titik koordinat yang terindikasi cut. Tim langsung melakukan perbaikan dilokasi. Langkah akhir tim melakukan pengecekan kembali di sisi DP untuk memastikan hasil power input DP normal Confidential Documentation Workflow Distribution Engineer FTTH (DISTRIBUTION) POWER LOW Confidential Documentation Troubleshooting Distribusi FTTH (Power Low) Langkah awal troubleshoot yang pertama di lakukan adalah cek input DP Apabila hasil redaman besar (< -24dBm), pengecekan dilanjutkan di sisi RK, ukur pada output spliter yang mengarah ke DP yang terkendala Jika hasil ukur di output splitter OK, kendala kemungkinan ada di kabel distribusi dari RK ke DP tersebut. Confidential Documentation Troubleshooting Distribusi FTTH (Power Low) Melakukan pengukuran (OTDR) kearah DP dari Cassete distribusi di RK untuk mengetahui event yang menyebabkan power low Confidential Documentation Troubleshooting Distribusi FTTH (Power Low) Koordinasi ke Dipatcher prihal Datek (data teknis) infrastruktur FTTH sesuai daerah mana yang terkendala, untuk keperluan tracing event yang menyebabkan redaman besar. Tim menuju lokasi/titik koordinat yang terindikasi redaman besar. Tim langsung melakukan perbaikan dilokasi. Langkah akhir tim melakukan pengecekan kembali di sisi DP untuk memastikan hasil power input DP normal. Confidential Documentation Workflow Backbone Engineer FTTH (BACKBONE) LOSS Confidential Documentation Troubleshooting Backbone FTTH (Loss) Melakukan pengukuran (OTDR) pada cassete backbone kearah SPOP, terlihat dari hasil pengukuran terdapat titik cut di jarak sesuai hasil ukuran Koordinasi ke Dipatcher prihal Datek (data teknis) infrastruktur FTTH kabel Backbone sesuai daerah mana yang terkendala, untuk keperluan tracing titik cut. Confidential Documentation Troubleshooting Backbone FTTH (Loss) Tim menuju lokasi/titik koordinat yang terindikasi cut. Tim langsung melakukan perbaikan dilokasi. Langkah akhir tim melakukan pengecekan kembali di sisi RK untuk memastikan hasil power input BB normal. Confidential Documentation Workflow Backbone Engineer FTTH (BACKBONE) POWER LOW Confidential Documentation Troubleshooting Backbone FTTH (Power Low) Melakukan pengukuran (OTDR) kearah SPOP, terlihat dari hasil pengukuran terdapat event yang menyebabkan redaman besar sesuai hasil ukur. (gambar terlampir) Koordinasi ke Dipatcher perihal Datek (data teknis) infrastruktur FTTH kabel Backbone sesuai daerah mana yang terkendala, untuk keperluan tracing event yang menyebabkan redaman besar. Note : pada pengukuran ke arah SPOP, path cord disisi OTB (SPOP) harus di unplugged Confidential Documentation Troubleshooting Backbone FTTH (Power Low) Tim menuju lokasi/titik koordinat yang terindikasi bending. Tim langsung melakukan perbaikan dilokasi. Langkah akhir tim melakukan pengecekan kembali di sisi RK untuk memastikan hasil power input BB normal. Confidential Documentation Workflow Project Engineer Confidential Documentation Questions? Confidential Documentation K3 di Ketinggian Confidential Documentation Brainstorming Confidential Documentation Brainstorming Bekerja di ketinggian merupakan suatu kegiatan /aktifitas yang dikategorikan sebagai "Class 1 Risk Activities" Berdasarkan laporan Labour Force Survey (LFS2) UK, Salah satu penyebab terjadinya kecelakaan kerja yang berdampak pada cidera serius dan kematian adalah terjatuh dari atas ketinggian (31%) Sebagian besar terjadi pada pekerja bidang konstruksi (11%). Confidential Documentation Safety Working at Height Bekerja di Atas Ketinggian adalah suatu kegiatan atau aktifitas yang dilakukan object dalam hal ini adalah pekerja yang mempunyai resiko jatuh dari atas ketinggian yang apabila diukur dari base elevation/lantai dasar ke titik jatuh 1.8 meter. Confidential Documentation Safety Working at Height Confidential Documentation Safety Working at Height Persyaratan ketika akan bekerja di atas ketinggian : Pekerja harus dalam kondisi fit sebelum melakukan kegiatan bekerja di atas ketinggian dan tidak mempunyai riwayat penyakit kronis Semua pekerja sebelum melakukan kegiatan bekerja di atas ketinggian harus sudah mendapat pelatihan “Bekerja di Ketinggian” Prosedure kerja aman (JSEA) harus dibuat oleh semua pekerja yang terlibat dalam bekerja di ketinggian & semua pekerja yang harus berpartisipasi dalam rumusan JSEA. Semua peralatan Penahan dan Pencegah Jatuh serta Peralatan Pendukung harus dalam kondisi baik dan sudah diinspeksi sebelum digunakan Semua peralatan pendukung (EWP, Scaffold, Ladders, dll) sesuai dengan persyaratan standard, dan dididirikan atau dioperasikan oleh orang yang berkompeten Confidential Documentation Safety Working at Height Gangguan Kesehatan ketika bekerja di atas ketinggian : - Hipoksia : Kekurangan oksigen dalam darah - Dekompresi/Bends : Kesulitan bernafas - Chokes : Tersedak - Sinusitis Kronik : Radang pada rongga sinus - Gangguan Penglihatan - Barodontalgia : Sakit gigi saat di ketinggian - Gangguan proses mental dan pisikologi Confidential Documentation Safety Working at Height Faktor – faktor umum yang berkontribusi pada risiko seseorang terjatuh dari atas ketinggian: a) People (Manusia) b) Environment (Lingkungan) c) Equipment (Peralatan) + Procedure (Prosedur) + Organization (Organisasi) Confidential Documentation Safety Working at Height Confidential Documentation Alat Pelindung Diri (APD) Check List APD Engineer Biznet: 1. Safety Helmet 2. Masker 3. Safety Glasses 4. Safety Vest 5. Body / Seat Herness 6. Sarung Tangan 7. Safety Shoes Confidential Documentation Confidential Documentation Safety Working at Height Metode dan tindakan pencegahan dalam penggunaan tangga adalah: 1. Jangan menggunakan tangga yang rusak 2. Letakkan tangga pada permukaan yang rata dan kaki tangga seimbang 3. Pastikan ada satu orang untuk memegang tangga pada bagian bawah ketika sedang digunakan 4. Ujung tangga harus lebih tinggi sekitar 1 meter di atas lantai kerja Confidential Documentation Safety Working at Height 5. Jangan menambahkan tangga tambahan sehingga tangga tumpang tindih 6. Jangan berdiri di atas ujung tangga, maksimal 2 step dari anak tangga teratas untuk pegangang tangan 7. Selalu berdiri menghadap tangga dengan tangan memegang anak tangga. Jangan bekerja di samping kiri atau kanan. 8. Berdirikan tangga dengan perbandingan sudut 1:4 atau dengan sudut 75 derajat. Boleh kurang, asalkan terdapat penopang pada bagian bawah tangga. Confidential Documentation Safety Working at Height 9. Gunakan metode three point contact saat naik/turun tangga. Three point contact yaitu 2 kaki berpijak dengan satu tangan berpegang pada anak tangga dan satu tangan bergerak menanggapi tangga atau 2 tangan berpegang pada anak tangga dengan satu kaki berpijak dan kaki lain bergerak menggapai tangga. Confidential Documentation Safety Working at Height 3 Langkah Awal Penanganan Korban Kecelakaan: Respon korban (AVPU) tenangkan korban dan amankan korban. Cek kesadaran korban, Cek Breathing dan nafas (bila tidak bernafas atau nadi tidak teraba, lakukan prosedur RJP) Lakukan penanganan luka pada korban (bila terdapat luka atau fraktur) Confidential Documentation Questions? Edit Master text styles Confidential Documentation Thank You Biznet MidPlaza 2, 8th floor Jl. Jend. Sudirman 10-11 Jakarta 10220 - Indonesia biznetnetworks.com Confidential Documentation

Use Quizgecko on...
Browser
Browser