Electron Diffraction PDF
Document Details
Uploaded by IntelligibleOmaha
null
Tags
Related
- X-Ray Diffraction (XRD) and Crystal Structure - University of Tabuk - PDF
- Direct Evidence for a Carbon-Carbon One-Electron σ-Bond PDF
- Diffraction Techniques and Microscopy PDF
- Materials Inspection and Characterization-I PDF
- Reviewer - Modern Physics Midterm PDF
- XRD Notes PDF - Analytical Instrumentation
Summary
This document describes electron diffraction, including the experiment's objectives, theory, and safety precautions. It covers the history and theory behind electron diffraction and provides experimental procedures. The document focuses on understanding wave-like properties of matter and calculating intra-atomic spacings within a graphite target.
Full Transcript
Electron Diffraction Experiment objectives: observe diffraction of the beam of electrons on a graphitized carbon target, and to calculate the intra-atomic spacings in the graphite. History A primary tenet of quantum mechanics is the wavelike properties of matter. In 1924, graduate student Louis de...
Electron Diffraction Experiment objectives: observe diffraction of the beam of electrons on a graphitized carbon target, and to calculate the intra-atomic spacings in the graphite. History A primary tenet of quantum mechanics is the wavelike properties of matter. In 1924, graduate student Louis de Broglie suggested in his dissertation that since light has both particle-like and wave-like properties, perhaps all matter might also have wave-like properties. He postulated that the wavelength of objects was given by λ = h/p, where where h is Planck’s constant, and p = mv is the momentum. This was quite a revolutionary idea, since there was no evidence at the time that matter behaved like waves. In 1927, however, Clinton Davisson and Lester Germer discovered experimental proof of the wave-like properties of matter- particularly electrons (This discovery was quite by mistake!). They were studying electron reflection from a nickel target. They inadvertently crystallized their target while heating it, and discovered that the scattered electron intensity as a function of scattering angle showed maxima and minima. That is, electrons were “diffracting” from the crystal planes much like light diffracts from a grating, leading to constructive and destructive interference. Not only was this discovery important for the foundation of quantum mechanics (Davisson and Germer won the Nobel Prize for their discovery), but electron diffraction is an extremely important tool used to study new materials. In this lab you will study electron diffraction from a graphite target, measuring the spacing between the carbon atoms. d θ Figure 1: Electron Diffraction from atomic layers in a crystal. Theory Consider planes of atoms in a crystal as shown in Fig, 1 separated by distance d. Electron ”waves” reflect from each of these planes. Since the electron is wave-like, the combination of the reflections from each interface will lead to an interference pattern. This is completely analogous to light interference, arising, for example, from different path lengths in the Fabry-Perot or Michelson interferometers. The de Broglie wavelength for the electron is given by: λ = h/p, where p can be calculated by knowing the energy of the 1 electrons when they leave the “electron gun”: p2 = eVa , (1) 2m where Va is the accelerating potential. The condition for constructive interference is that the path length difference for the two waves shown in Fig. 1 be a multiple of a wavelength. This leads to Bragg’s Law: nλ = 2d sin θ (2) where n = 1, 2,... is integer. In this experiment, only the first order diffraction n = 1 is observed. Therefore, the intra-atomic distance in a crystal can be calculated by measuring the angle of electron diffraction and their wavelength (i.e. their momentum): λ 1 h d= = √ (3) 2 sin θ 2 sin θ 2eme Va where h is Planck’s constant, e is the electronic charge, me is the electron’s mass, and Va is the accelerating voltage. Experimental Procedure Equipment needed: Electron diffraction apparatus and power supply, masking tape, ruler. Safety You will be working with high voltage. Power supply will be connected for you, but inspect the apparatus when you arrive before turning the power on. In any wires are unplugged, ask an instructor to reconnect them. Also, before turning the power on, identify the high voltage contacts on the electron diffraction tube, make sure these connections are well-protected and cannot be touched by accident while taking measure- ments. Figure 2: Electron Diffraction Apparatus. 2 d = d inner 10 d outer =d11 Figure 3: Spacing of carbon atoms. Here subscripts 10 and 11 correspond to the crystallographic directions in the graphite crystal. Setup The diagram of the apparatus is given in Fig.2. An electron gun (consisting of a heated filament to boil electrons off a cathode and an anode to accelerate them to, similar to the e/m experiment) “shoots” electrons at a carbon (graphite) target. The electrons diffract from the carbon target and the resulting interference pattern is viewed on a phos- phorus screen. The graphitized carbon is not completely crystalline but consists of crystal sheets in random orientations. Therefore, the constructive interference patterns will be seen as bright circular rings. For the carbon target, two rings (an outer and inner, corresponding to different crystal planes) will be seen, corresponding to two spacings between atoms in the graphite arrangement, see Fig. 3 Data acquisition Acceptable power supplie settings: Filament Voltage VF 6.3 V ac/dc (8.0 V max.) Anode Voltage VA 1500 - 5000 V dc Anode Current IA 0.15 mA at 4000 V ( 0.20 mA max.) 1. Switch on the heater and wait one minute for the oxide cathode to achieve thermal stability. 2. Slowly increase Va until you observe two rings to appear around the direct beam. Slowly change the voltage and determine the highest achievable accelerating voltage, and the lowest voltage when the rings are visible. 3. Measure the diffraction angle θ for both inner and outer rings for 5-10 voltages from that range, using the same masking tape (see procedure below). Each lab partner should repeat these measurements (using an individual length of the masking tape). 4. Calculate the average value of θ from the individual measurements for each voltage Va. Calculate the uncertainties for each θ. Measurement procedure for the diffraction angle θ To determine the crystalline structure of a target, one needs to carefully measure the diffraction angle θ. It is easy to see (for example, from Fig.(1) that the diffraction angle θ is 1/2 of the angle φ between the beam incident on the target and the diffracted beam to a ring. To measure φ carefully place a piece of masking tape on the tube so that it crosses the ring along the diameter. Mark the position of the ring for each accelerating voltage, and then remove the masking tape and measure the arc length s corresponding to each ring. 3 Figure 4: Geometry of the experiment. The ratio between the arc length and the distance between the target and the radius of the curvature of the screen R = 0.066 m gives the angle φ in radian: φ = s/2R. Then, the diffraction angle θ for a given accelerated voltage can be found from simple geometrical ratio L sin 2θ = R sin φ, (4) where the distance between the target and the screen L = 0.130 m is controlled during the production process to have an accuracy better than 2%. Data analysis Use the graphical method to find the average values for the distances between the atomic planes in the graphite crystal d11 (outer ring) and d10 (inner ring). To determine the combination of the experimental parameters that is proportional to d, one need to substitute the expression for the electron’s velocity Eq.(1) into the diffraction condition given by Eq.(5): h 1 2d sin θ = λ = √ √ (5) 2me e Va √ Make a plot of 1/ Va versus sin θ for the inner and outer rings both curves can be on the same graph). Fit the linear dependence and measure the slope for both lines. From the values of the slope find the distance between atomic layers dinner and douter. Compare your measurements to the accepted values : dinner = d10 =.213 nm and douter = d11 = 0.123 nm. Looking with Electrons The resolution of ordinary optical microscopes is limited (the diffraction limit) by the wavelength of light (≈ 400 nm). This means that we cannot resolve anything smaller than this by looking at it with light (even if we had no limitation on our optical instruments). Since the electron wavelenght is only a couple of angstroms (10−10 m), with electrons as your “light source” you can resolve features to the angstrom scale. This is why “scanning electron microscopes” (SEMs) are used to look at very small features. The SEM is very similar to an optical microscope, except that “light” in SEMs is electrons and the lenses used are made of magnetic fields, not glass. 4