This document contains a check list for an Engineering Scale Plan (ESP). It details various requirements for the plan, including yard layout, gradients, and station features. The document appears to be instructions for creating a railway plan.
Full Transcript
Para No. 8.1.1 Annexure: 8-A2 Check List for Engineering Scale Plan (ESP) REMARKS OF S. Description of the Ite...
Para No. 8.1.1 Annexure: 8-A2 Check List for Engineering Scale Plan (ESP) REMARKS OF S. Description of the Item JE/SE/SSE/ SSTE/ No. ADSTE Drg DSTE 1. Complete layout of the yard should be shown by the Engg. Dept. even for works for minor nature. Alteration/Modification should not be shown in a part plan. 2. Plan should be prepared in 1:1000 scale 3. North Point should be shown on the top of the sheet. 4. Kilometerage and Chainage (0.00 m) of the station building should be clearly indicated. 5. Direction of Train movement i.e. UP & DN should be clearly indicated at the top centre as well as at the ends of the yard. 6. Name of the adjacent Block Stations with their distances at both ends and name of the Junction Stations to be indicated. The Kilometerage shall start incrementing from left hand side to right hand side & mid section siding if any to be shown. 7. All Gradient at the yard must be shown and should be in sequence. Gradient & its chainages upto 2.5 km from first stop signal both ends should be shown. 8. a) Gradient of new Stn. Yard within 50 m from outermost point should be 1 in 1200. Permitted upto 1 in 400 with out condonation. b) Allowed upto 1 in 400. CRS‘s Dispensation required for gradient steeper than 1 in 400 upto 1 in 260. Rly.Bd’s Condonation required for gradient steeper than 1 in 260. Despensation or condonation obtained/to be obtained should be indicated clearly in Engg Scale Plan. 9. There must be no change of grades within 30 meters of any points & crossing. 10. If any alteration is proposed for the existing yard, the portion of the yard where alteration is proposed shall be marked with Red colour, and the portion of the yard where alteration is not proposed is tallying with the existing sigg. Plan 11. All Lines should be designated for identification and reference. All lines No. to be written starting line No.1 from station Bldg. side. Chapter 8: Drawings & Specifications Page 178 of 530 REMARKS OF S. Description of the Item JE/SE/SSE/ SSTE/ No. ADSTE Drg DSTE 12. The clear standing room of all lines e.g., running lines, Sdg. Lines, should be mentioned. CSL should be minimum 720 m for New lines and 686 m for existing lines. 13. Platforms should be provided on lines on which it is intended to receive passenger trains.Platform level e.g, RL, LL, HL etc. to be indicated. 14. The classification, kilometerage, chainage from Centre of station building, Manned/ Unmanned and number of each level crossing should be shown. Classifications of L.C. Gates are to be revised according to present TVU. Spl- >50000, A->/=30000 & /=25000 & /=20000 &