Skillcat EPA Answers20240427112459.docx

Full Transcript

**Skillcat EPA Answers** EPA608 Universal\ \ A compound pressure gauge, typically used on the low side of the system, measures pressure in: - **psig and inches of mercury**\ \ Violations of the Clean Air Act? - falsifying or failing to keep required records; failing to reach required evacuation le...

**Skillcat EPA Answers** EPA608 Universal\ \ A compound pressure gauge, typically used on the low side of the system, measures pressure in: - **psig and inches of mercury**\ \ Violations of the Clean Air Act? - falsifying or failing to keep required records; failing to reach required evacuation levels before opening or disposing of appliances; knowingly releasing CFC or HCFC refrigerants or their substitutes while repairing appliances.\ \ Refrigerant that enters the compressor, under normal operating conditions, is a: - **low pressure vapor.**\ \ Ozone depletion in the stratosphere is what type of problem? - **GLOBAL**.\ \ Refrigeration technicians who violate the Clean Air Act can: -\ **Lose their EPA certification, be fined, be required to appear in Federal court.\ **\ After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: -\ **recovery and recycling.**\ \ Refrigerant that is recovered can be returned to: -\ **The same system or other systems owned by the same person without restriction.**\ \ Refrigerant can not be called \"reclaimed\" unless it: -.\ **Has been chemically analyzed and the refrigerant meets the ARI-700 standard.**\ \ The EPA can require a technician to demonstrate their ability to perform proper procedures for recovering and/or recycling refrigerant. Failure to demonstrate competency can result in: -\ **revocation of the technicians certification.**\ \ What characteristic(s) of CFCs make them more likely to reach the stratosphere than most other compounds containing chlorine? -\ **Refrigerants that contain chlorine but not hydrogen are so stable that they do not break down in the lower atmosphere after being released. The chlorine or bromine reacts with the ozone, causing it to change back to oxygen, thus destroying the ozone layer.\ **\ A system is considered dehydrated when: -\ **The vacuum indicator shows you have reached and held the required finished vacuum.**\ \ Disposable refrigerant containers are used for \_\_\_\_\_\_\ **Virgin refrigerant**\ \ Which refrigerant is an HCFC? -\ **R-123, R-124, R-22**\ \ What statement is true about an azeotropic refrigerant mixture? -\ **It is a mixture that acts like a single-component refrigerant over its entire range.\ **\ Chlorofluorocarbos (CFCs) and hydrochlorofluorocarbons (HCFCs) have which of the following in common? -\ **It is a mixture that acts like a single-component refrigerant over its entire range.**\ \ To scrap a disposable cylinder, the internal cylinder pressure should be reduced to at least: -\ **0 psig.**\ \ Manifold gauge sets are often color coded, when this is done, the high pressure gauge is color coded: - **Red.**\ \ In general, blended refrigerants should be charged: -\ **As a liquid.**\ \ Blended refrigerants leak from a system: -\ \ **in uneven amounts due to different vapor pressures.**\ \ Which of the following gases help form the earth\'s protective shield? **- Stratospheric Ozone**\ \ In a refrigerant system, the device that changes a low pressure vapor to a high pressure vapor is the: - **compressor.**\ \ Data shows that chlorine in the stratosphere comes mainly from CFCs rather than from natural sources such as volcanoes because: - The rise in the amount of chlorine in the stratosphere matches the rise in the amount of fluorine, which has different natural sources than chlorine; The rise in the amount of chlorine in the stratosphere matches the rise in CFC emissions; Air samples taken from the stratosphere over erupting volcanoes show that volcanoes contribute a small quantity of chlorine to the stratosphere when compared to CFCs;\ \ Which atom of the CFC molecule causes ozone depletion? - **chlorine**\ \ The ozone layer protects the earth from: - **ultraviolet radiation from the sun.\ **\ When using with any solvent, cleaner, chemical or refrigerant, you should review: - **material safety data sheets.\ **\ An award of up to what amount may be paid to a person supplying information that leads to a penalty against a technician who is intentionally venting? - **10,000**\ \ The Montreal Protocol is: - **a treaty among nations that controls production of CFCs and HCFCs.\ **\ Which refrigerant is an HCFC? - **R-123, R-22, R-124\ **\ What is one of the most serious results of damage to the ozone layer? - **increases in human skin cancer\ **\ Of the refrigerants listed below, which has the lowest ozone depletion potential (ODP)? - **R-22**\ \ To determine the maximum allowable pressure to use when checking a system, check: - t**he design pressure on the equipment nameplate\ **\ Ozone depletion potential, or \"ODP,\" is: - **A measure of the ability of CFCs and HCFCs to destroy ozone.\ **\ An example of an HFC refrigerant is: - **R-134a**\ \ Whenever dry nitrogen from a portable cylinder is connected to a system, what item is of most importance in consideration of safety? - **There is relief in the downstream line from the pressure regulator.\ **\ During servicing of a refrigeration system containing R-12, the refrigerant must be: - **recovered.**\ \ Which safety precaution(s) should always be followed: - **Never apply an open flame to a refrigerant cylinder; never cut or weld any refrigerant line when refrigerant is in the line; never use oxygen to purge lines or to pressurize a system.\ **\ In a vapor compression refrigeration system, cooling occurs when: - **refrigerant liquid turns to a vapor.\ **\ The evacuation of a system is a method of: - **dehydration.**\ \ Each chlorine atom in the stratosphere can destroy\_\_\_\_ozone molecules. - **100,000**\ \ An example of a HFC refrigerant is: - **R-410A**\ \ Which gas(es) would cause the LEAST damage to the environment during a leak check? - **dry nitrogen\ **\ Refrigerant migrates to the compressor crankcase because of a difference in\_\_\_\_\_\_between the refrigerant and the oil. - **vapor pressure.\ **\ Which refrigerant is an HCFC? - **R-22, R-123, R-124\ **\ It is important not to mix R-22 and R-410A refrigerants in the same container because: - **the mixture may be impossible to reclaim.**\ \ When using recover unit, the fill level of the recovery tank can be controlled by: - **a mechanical switch; an electronic shut-off device; weight\ **\ Which of the following refrigerant releases is a violation of the EPA prohibition on venting? - **release of mixtures of nitrogen and refrigerant that result from adding nitrogen to a fully charged appliance to \"leak-check\" the appliance.\ **\ Which of the following human health effects could result from an increase in ultraviolet radiation? - **an increase in cataracts cases\ **\ Never use an open flame to heat a refrigerant tank because: - **it can result in venting refrigerant to the atmosphere; the tank may explode, causing serious injury to people nearby; refrigerant in the tank may decompose, forming a toxic material.\ **\ When transporting cylinders containing used refrigerant, the DOT requires that you: - **attach DOT classification tags\ **\ According to ASHRAE\'s 1992 refrigerant safety classification which of the following designations would be the most safe? - **A-1**\ \ The over-evacuation of a system: - **does not occur.\ **\ Equipment covered by EPA regulations include: - **all air-conditioning and refrigeration equipment using CFC, HCFC or HFC refrigerants.\ **\ Never overfill refrigerant storage cylinders because: - t**he internal pressure of the cylinders may rise in heated areas and cause an explosion.\ **\ It is important not to mix different refrigerants in the same container because: - **the mixture may be impossible to reclaim.\ **\ Manifold gauge sets are often color coded, when this is done, the low pressure gauge is color coded: - **blue.\ **\ All devices used for a refrigerant recovery must: - **Meet EPA standards**\ \ Reusable refrigerant containers that are normally under any pressure above 15 pig must be hydrostatically tested and date stamped every: - **5 Years**\ \ Which refrigerant(s) must be recovered before opening a system or disposing of a system? - **all refrigerants must be recovered.**\ \ To obtain an accurate vacuum readings during system evacuation, the system vacuum gauge should be located: - **as far from the vacuum pump as possible.\ **\ What is the best proof that CFCs are in the stratosphere? - **measurements of CFCs in air samples from the stratosphere\ **\ The recovery of refrigerants is necessary to: - **maintain adequate supplies for service calls after the production bans; prevent the venting of refrigerants to the atmosphere; prevent stratospheric ozone depletion\ **\ An example of an HFC refrigerant is: - **R-410A\ **\ A compound pressure gauge, typically used on the low side of the system, measures pressure in: - psig and inches of mercury\ \ \_\_\_\_\_\_\_\_\_\_\_\_\_\_refers to the process of cleaning refrigerant by oil separation and single or multiple passes through filter-driers, which reduce moisture and acidity? - Recycling\ \ The high pressure gauge on service manifold sets has a continuous scale, usually calibrated to read from: - 0 to 500 psi\ \ \_\_\_\_\_\_\_\_\_is the process that returns refrigerant to new-product specifications and that requires chemical analysis? - Reclaim\ \ A cylinder with a gray body and a yellow top indicates that the cylinder is designed to hold: - recovered refrigerant\ \ HFC refrigerants: - are less harmful to stratospheric ozone than CFCs\ \ Which type of refrigerant is the most harmful to stratospheric ozone? - Refrigerants containing Bromine\ \ According to the EPA, a\_\_\_\_\_\_\_ leak detection method is considered to be the most effective for locating the general area of a small leak. - electronic or ultrasonic tester\ \ Long hoses between the unit and the recovery machine should not be used because they cause: - excessive pressure drop; increased recovery time; increased emissions\ \ Recovery equipment that relies upon the compressor in the system would be considered: - system-dependent.\ \ A hermetic compressor must never be operated when: - there is a dehydration vacuum in the system.\ \ \"Self-contained\" recovery devices: - can capture liquid and/or vapor refrigerant without the assistance of components in the air-conditioning or refrigeration equipment.\ \ Systems charged with R-410A should be leak checked with: - **pressurized nitrogen.**\ \ R-410A is not a typical blended refrigerant because: - It is near azeotropic refrigerant; it can be charged as either a liquid or vapor; while it has a 400 series refrigerant number it behaves like a 500 series refrigerant\ \ A ternary refrigerant blend is a \_\_\_\_\_\_\_ part mixture. - **three-part\ **\ In a refrigeration system, high pressure vapor is converted to high pressure liquid in the: - **condenser.\ **\ Which of the following is an approved \"drop-in\" service replacement for r-12? - **According to the EPA there are no \"drop-in\" replacements\ **\ The proper method of discarding a disposable refrigerant cylinder is to: - **assure that all refrigerant is recovered and that the cylinder is rendered useless, then recycle the metal.\ **\ CFC refrigerants are so named because they contain the elements: - **Chlorine, fluorine, carbon**\ \ Before you dispose of any system containing a refrigerant, you must: - recover the refrigerant.\ \ According to EPA regulations, which of the following procedures is NOT an approved technique for system cleanup after a burnout? - **flushing with liquid refrigerant to clean tubing\ **\ When using nitrogen to pressurize a system, you should always: - **charge though a pressure regulator.**\ \ What effects can ozone depletion have on the environment? - **reduced crop yields; reduced marine life; increased ground-level ozone\ **\ Non-azeotropic refrigerants leak from a system: - **in uneven amounts due to different vapor pressures.\ **\ An example of an HCFC is: - **R-22**\ \ Which chemicals are controlled by the Montreal Protocol? - **chlorofluorocarbons, hydrochlorofluorocarbons, halons\ **\ Systems charged with R-134a should be leak checked with: - **pressurized nitrogen.\ **\ When evacuating a system, the hoses should be: - equal to or larger than vacuum pump inlet connection.\ \ It has been illegal to vent substitutes for CFC and HCFC refrigerants since: - November 1995\ \ Never use oxygen or compressed air to pressurize a system because: - when mixed with compressor oil or some refrigerants, it could explode.\ \ Refrigerant cylinders should always be: - free of rust and damage; color coded to indicate the contents; secure\ \ Even though R-22 is considered non-toxic, it: - can cause asphyxia.\ \ A system is dehydrated to: - remove water and water vapor.\ \ According to the EPA, of the refrigerants liked below, which types of refrigerants will not contribute to Global Warming? - CFCs HCFCs HFCs all contribute to Global Warming\ \ The type of oil that is most commonly used in stationary air conditioning applications with HFC-410A refrigerant is: - ester oil.\ \ Technicians receiving a passing grade on the Type II (medium-pressure, high-pressure and very high pressure) exam are certified to recover refrigerant during the maintenance, service, or repair of medium- and high-pressure equipment and very high pressure refrigerants, including: - With Type II certification, you are certified for all very high pressure refrigerants including CFC-13 and CFC-503\ \ PPE(gloves, safety glasses, safety shoes, etc.) should always be worn is when: - handling and filling refrigerant cylinders.\ \ Refrigerant vapors or mist should not be inhaled because - they may cause heart irregularities and/or unconsciousness.\ \ Violations of the Clean Air Act? - falsifying or failing to keep required records; failing to reach required evacuation levels before opening or disposing of appliances; knowingly releasing CFC or HCFC refrigerants or their substitutes while repairing appliances.\ \ HFC refrigerants contain: - hydrogen, fluorine, carbon\ \ Which refrigerant contains an HCFC? - R-22\ \ Recovery equipment that relies upon the pressure of the refrigerant in the appliance would be considered: - System-dependent\ \ Refrigerant that enters the compressor, under normal operating conditions, is a: - low pressure vapor.\ \ It is necessary to place a refrigerant label on: - a refrigerant cylinder which is being returned for reclaiming.\ \ Which refrigerant contains a CFC? - R-500\ \ Use\_\_\_\_\_\_\_\_ to remove ice from a sight glass. - an alcohol spray.\ \ According to the EPA, an oil sample should be taken for which of the following reasons? - They system had a leak or a major component failure.\ \ The EPA requires the installation of a service aperture or process stub on all appliances using a class I or class II substance as a refrigerant. The main purpose of this requirement is to make it easier to: - recover refrigerant.\ \ Recycling and recovery equipment intended for use with air-conditioning and refrigeration equipment(except for small appliances) must be tested under: - ARI 740\ \ Refrigerant entering the compressor of a refrigeration system is a: - superheated vapor.\ \ What is being done in the U.S. to stop damage to the stratospheric ozone layer? - capturing and ultimately eliminating use of chlorofluorocarbons.\ \ They type of oil that is most commonly used in stationary refrigeration applications with HFC-134a refrigerant is: - ester oil.\ \ The term used to describe the fact that a refrigerant blend has a range of boiling or condensing pints at a constant pressure is: - temperature glide.\ \ Which refrigerant contains a CFC? - R-12\ \ Under EPA\'s regulations, what standard must reclaimed refrigerant meet before it can be resold? - ARI 700\ \ An example of a HFC refrigerant is: - R-134a\ \ It is illegal to: - knowingly release any refrigerant during the service, maintenance, repair or disposal of appliances, with the exception of de minimis releases.\ \ Which type of refrigerant is the most harmful to stratospheric ozone? - CFC\ \ Refrigerant that enters the expansion or throttling device (also known as the metering device) is a: - liquid.\ \ Which of the following statements would be considered good service practices for conserving refrigerant? - recover or recycle refrigerant; keep systems tight; find and repair leaks\ \ Under the EPA \"safe disposal requirements\", the person responsible for making sure that the refrigerant has been removed from household refrigerators before they are disposed of is the: - final person in the disposal chain\ \ Which refrigerant listed below is a \"low-pressure refrigerant\" under EPA\'s refrigerant recycling regulations? - R-123\ \ When moisture exists in an operating system, which of the following is the most likely to occur? - Acid will form\ \ Which of the following is a \"very high-pressure refrigerant\" under EPA\'s refrigerant recycling regulations? - R-13\ \ When using nitrogen to pressurize a system, you should: - only charge with nitrogen vapor.\ \ Of the refrigerants listed below, which has the lowest ozone depletion potential? - R-134a\ \ When dealing with small systems, how many different refrigerants may be recovered into the same cylinder? - ONLY ONE\ \ When operating refrigerant recovery or recycling equipment, the following precautions should always be followed - wear safety glasses; wear protective gloves; follow all safety precautions for the equipment\ \ Of the refrigerants listed below, which types of refrigerants will not damage stratospheric ozone? - HFCs\ \ When evacuating a system, the hoses should b: - as short in length and as large in diameter as possible.\ \ Refrigerant leaves the condenser of an operating system as a: - high pressure liquid.\ \ If corrosion is found within the body of a relief valve, the valve must be: - replaced.\ \ The Clean Air Act: - sets a schedule for the phase out of CFC/HCFC production; prohibits venting of refrigerants; authorizes the EPA to set standards for recover of refrigerants.\ \ Measuring the system\'s final vacuum is always done with: - the system isolated and the vacuum pump off.\ \ A refillable refrigerant cylinder must never be filled to more than\_\_\_\_\_\_\_\_\_ of its capacity by weight: - 80%\ \ Of the refrigerants listed below, which refrigerant type have the highest ozone depletion potential? - CFCs\ \ This chemical was found in the upper stratosphere and that indicates that the ozone layer is being destroyed. - chlorine monoxide\ \ What factor(s) affects the speed of evacuation? - the size of the equipment being evacuated; the ambient temperature; the amount of moisture in the system\ \ HCFC refrigerants contain: - hydrogen, chlorine, fluorine, carbon\ \ When a system will not hold vacuum after is has been evacuated, then: - they system may be leaking.\ \ All recovery equipment currently being made is required to have: - an EPA approved certification label.\ \ The color code for approved refrigerant recovery cylinders is\_\_\_\_\_\_. - yellow tops and gray bodies\ \ When can you use a disposable cylinder to recover refrigerant? - never\ \ Which of the following is a \"high-pressure refrigerant\" under EPA\'s refrigerant recycling regulations? - R-22\ \ After refrigerant liquid transfer between recovery unit and the system being emptied, you need to avoid trapping: - liquid refrigerant between service valves.\ \ You can determine safe pressure for leak testing a system from the: - low-side test-pressure data-plate value.\ \ If a technician has a system where some R-502 was added to an R-22 system. The technician should: - recover all the refrigerant into a separate tank.\ \ Ozone in the stratosphere above the earth consists of: - molecules of 3 oxygen atoms.\ \ The size (capacity) of the vacuum pump and the size of the suction line used will determine: - the length of dehydration time.\ \ According to the EPA, when dealing with customer complaints regarding additional costs due to refrigerant recovery efforts, the technician should: - explain the refrigerant recovery is necessary to protect human health and the environment; explain that refrigerant recovery is required by the Federal(and in some cases state and local)laws; inform the customer that professional service personnel are duty bound to follow the law and to protect the environment\ \ State and local governments can make state laws that: - follow the Clean Air Act/EPA regulations; contain stricter regulations than the Clean Air Act/EPA regulations.\ \ If an oil is hygroscopic it means that it: - readily absorbs moisture.\ \ When dehydrating a system, the system can be heated to: - decrease the dehydration time.\ \ The synthetic lubricant presently used with ternary blends containing HCFCs is: - alkylbenzene\ \ Ozone depletion in the stratosphere is what type of problem? - GLOBAL\ \ On a typical three port (three hose) manifold gauge, the center port is used for: - recovery, evacuation and charging.\ \ Ester based oils can be mixed with: - no other oils.\ \ CFCs will no longer be manufactured or imported into the United States after: - 1995\ \ Which type of refrigerants are chlorine-free? - HFCs\ \ Refrigerant recovery during low ambient temperatures will: - slow the recovery process.\ \ \_\_\_\_\_\_\_ is the process of removing refrigerant in any condition from a system and storing it in an external container without necessarily testing or processing it in any way. - Recovering\ \ Containers designated \"refillable\" by DOT are used for transporting recovered pressurized refrigerant\_\_\_\_\_\_\_\_. - to meet safety requirements Refrigeration technicians who violate the Clean Air Act can: - Lose their EPA certification, be fined, be required to appear in Federal court. After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - recovery and recycling. Refrigerant that is recovered can be returned to: - the same system or other systems owned by the same person without restriction. Refrigerant can not be called \"reclaimed\" unless it: -. has been chemically analyzed and the refrigerant meets the ARI-700 standard. The EPA can require a technician to demonstrate their ability to perform proper procedures for recovering and/or recycling refrigerant. Failure to demonstrate competency can result in: - revocation of the technicians certification. What characteristic(s) of CFCs make them more likely to reach the stratosphere than most other compounds containing chlorine? - Refrigerants that contain chlorine but not hydrogen are so stable that they do not break down in the lower atmosphere after being released. The chlorine or bromine reacts with the ozone, causing it to change back to oxygen, thus destroying the ozone layer. A system is considered dehydrated when: - the vacuum indicator shows you have reached and held the required finished vacuum. Disposable refrigerant containers are used for \_\_\_\_\_\_ virgin refrigerant Which refrigerant is an HCFC? - R-123, R-124, R-22 What statement is true about an azeotropic refrigerant mixture? - It is a mixture that acts like a single-component refrigerant over its entire range. Chlorofluorocarbos (CFCs) and hydrochlorofluorocarbons (HCFCs) have which of the following in common? - It is a mixture that acts like a single-component refrigerant over its entire range. To scrap a disposable cylinder, the internal cylinder pressure should be reduced to at least: - 0 psig. Manifold gauge sets are often color coded, when this is done, the high pressure gauge is color coded: - Red. In general, blended refrigerants should be charged: - as a liquid. Blended refrigerants leak from a system: - in uneven amounts due to different vapor pressures. Which of the following gases help form the earth\'s protective shield? - Stratospheric Ozone In a refrigerant system, the device that changes a low pressure vapor to a high pressure vapor is the: - compressor. Data shows that chlorine in the stratosphere comes mainly from CFCs rather than from natural sources such as volcanoes because: - The rise in the amount of chlorine in the stratosphere matches the rise in the amount of fluorine, which has different natural sources than chlorine; The rise in the amount of chlorine in the stratosphere matches the rise in CFC emissions; Air samples taken from the stratosphere over erupting volcanoes show that volcanoes contribute a small quantity of chlorine to the stratosphere when compared to CFCs; Which atom of the CFC molecule causes ozone depletion? - chlorine The ozone layer protects the earth from: - ultraviolet radiation from the sun. When using with any solvent, cleaner, chemical or refrigerant, you should review: - material safety data sheets. An award of up to what amount may be paid to a person supplying information that leads to a penalty against a technician who is intentionally venting? - 10,000 The Montreal Protocol is: - a treaty among nations that controls production of CFCs and HCFCs. Which refrigerant is an HCFC? - R-123, R-22, R-124 What is one of the most serious results of damage to the ozone layer? - increases in human skin cancer Of the refrigerants listed below, which has the lowest ozone depletion potential (ODP)? - R-22 To determine the maximum allowable pressure to use when checking a system, check: - the design pressure on the equipment nameplate Ozone depletion potential, or \"ODP,\" is: - A measure of the ability of CFCs and HCFCs to destroy ozone. An example of an HFC refrigerant is: - R-134a Whenever dry nitrogen from a portable cylinder is connected to a system, what item is of most importance in consideration of safety? - There is relief in the downstream line from the pressure regulator. During servicing of a refrigeration system containing R-12, the refrigerant must be: - recovered. Which safety precaution(s) should always be followed: - Never apply an open flame to a refrigerant cylinder; never cut or weld any refrigerant line when refrigerant is in the line; never use oxygen to purge lines or to pressurize a system. In a vapor compression refrigeration system, cooling occurs when: - refrigerant liquid turns to a vapor. The evacuation of a system is a method of: - dehydration. Each chlorine atom in the stratosphere can destroy\_\_\_\_ozone molecules. - 100,000 An example of a HFC refrigerant is: - R-410A Which gas(es) would cause the LEAST damage to the environment during a leak check? - dry nitrogen Refrigerant migrates to the compressor crankcase because of a difference in\_\_\_\_\_\_between the refrigerant and the oil. - vapor pressure. Which refrigerant is an HCFC? - R-22, R-123, R-124 It is important not to mix R-22 and R-410A refrigerants in the same container because: - the mixture may be impossible to reclaim. When using recover unit, the fill level of the recovery tank can be controlled by: - a mechanical switch; an electronic shut-off device; weight Which of the following refrigerant releases is a violation of the EPA prohibition on venting? - release of mixtures of nitrogen and refrigerant that result from adding nitrogen to a fully charged appliance to \"leak-check\" the appliance. Which of the following human health effects could result from an increase in ultraviolet radiation? - an increase in cataracts cases Never use an open flame to heat a refrigerant tank because: - it can result in venting refrigerant to the atmosphere; the tank may explode, causing serious injury to people nearby; refrigerant in the tank may decompose, forming a toxic material. When transporting cylinders containing used refrigerant, the DOT requires that you: - attach DOT classification tags According to ASHRAE\'s 1992 refrigerant safety classification which of the following designations would be the most safe? - A-1 The over-evacuation of a system: - does not occur. Equipment covered by EPA regulations include: - all air-conditioning and refrigeration equipment using CFC, HCFC or HFC refrigerants. Never overfill refrigerant storage cylinders because: - the internal pressure of the cylinders may rise in heated areas and cause an explosion. It is important not to mix different refrigerants in the same container because: - the mixture may be impossible to reclaim. Manifold gauge sets are often color coded, when this is done, the low pressure gauge is color coded: - blue. All devices used for a refrigerant recovery must: - Meet EPA standards Reusable refrigerant containers that are normally under any pressure above 15 pig must be hydrostatically tested and date stamped every: - 5 Years Which refrigerant(s) must be recovered before opening a system or disposing of a system? - all refrigerants must be recovered. To obtain an accurate vacuum readings during system evacuation, the system vacuum gauge should be located: - as far from the vacuum pump as possible. What is the best proof that CFCs are in the stratosphere? - measurements of CFCs in air samples from the stratosphere The recovery of refrigerants is necessary to: - maintain adequate supplies for service calls after the production bans; prevent the venting of refrigerants to the atmosphere; prevent stratospheric ozone depletion An example of an HFC refrigerant is: - R-410A A compound pressure gauge, typically used on the low side of the system, measures pressure in: - psig and inches of mercury \_\_\_\_\_\_\_\_\_\_\_\_\_\_refers to the process of cleaning refrigerant by oil separation and single or multiple passes through filter-driers, which reduce moisture and acidity? - Recycling The high pressure gauge on service manifold sets has a continuous scale, usually calibrated to read from: - 0 to 500 psi \_\_\_\_\_\_\_\_\_is the process that returns refrigerant to new-product specifications and that requires chemical analysis? - Reclaim A cylinder with a gray body and a yellow top indicates that the cylinder is designed to hold: - recovered refrigerant HFC refrigerants: - are less harmful to stratospheric ozone than CFCs Which type of refrigerant is the most harmful to stratospheric ozone? - Refrigerants containing Bromine According to the EPA, a\_\_\_\_\_\_\_ leak detection method is considered to be the most effective for locating the general area of a small leak. - electronic or ultrasonic tester Long hoses between the unit and the recovery machine should not be used because they cause: - excessive pressure drop; increased recovery time; increased emissions Recovery equipment that relies upon the compressor in the system would be considered: - system-dependent. A hermetic compressor must never be operated when: - there is a dehydration vacuum in the system. \"Self-contained\" recovery devices: - can capture liquid and/or vapor refrigerant without the assistance of components in the air-conditioning or refrigeration equipment. Systems charged with R-410A should be leak checked with: - pressurized nitrogen. R-410A is not a typical blended refrigerant because: - It is near azeotropic refrigerant; it can be charged as either a liquid or vapor; while it has a 400 series refrigerant number it behaves like a 500 series refrigerant A ternary refrigerant blend is a \_\_\_\_\_\_\_ part mixture. - three-part In a refrigeration system, high pressure vapor is converted to high pressure liquid in the: - condenser. Which of the following is an approved \"drop-in\" service replacement for r-12? - According to the EPA there are no \"drop-in\" replacements The proper method of discarding a disposable refrigerant cylinder is to: - assure that all refrigerant is recovered and that the cylinder is rendered useless, then recycle the metal. CFC refrigerants are so named because they contain the elements: - Chlorine, fluorine, carbon Before you dispose of any system containing a refrigerant, you must: - recover the refrigerant. According to EPA regulations, which of the following is procedures is NOT an approved technique for system cleanup after a burnout? - flushing with liquid refrigerant to clean tubing When using nitrogen to pressurize a system, you should always: - charge though a pressure regulator. What effects can ozone depletion have on the environment? - reduced crop yields; reduced marine life; increased ground-level ozone Non-azeotropic refrigerants leak from a system: - in uneven amounts due to different vapor pressures. An example of an HCFC is: - R-22 Which chemicals are controlled by the Montreal Protocol? - chlorofluorocarbons, hydrochlorofluorocarbons, halons Systems charged with R-134a should be leak checked with: - pressurized nitrogen. When evacuating a system, the hoses should be: - equal to or larger than vacuum pump inlet connection. It has been illegal to vent substitutes for CFC and HCFC refrigerants since: - November 1995 Never use oxygen or compressed air to pressurize a system because: - when mixed with compressor oil or some refrigerants, it could explode. Refrigerant cylinders should always be: - free of rust and damage; color coded to indicate the contents; secure Even though R-22 is considered non-toxic, it: - can cause asphyxia. A system is dehydrated to: - remove water and water vapor. According to the EPA, of the refrigerants liked below, which types of refrigerants will not contribute to Global Warming? - CFCs HCFCs HFCs all contribute to Global Warming The type of oil that is most commonly used in stationary air conditioning applications with HFC-410A refrigerant is: - ester oil. Technicians receiving a passing grade on the Type II (medium-pressure, high-pressure and very high pressure) exam are certified to recover refrigerant during the maintenance, service, or repair of medium- and high-pressure equipment and very high pressure refrigerants, including: - With Type II certification, you are certified for all very high pressure refrigerants including CFC-13 and CFC-503 PPE(gloves, safety glasses, safety shoes, etc.) should always be worn is when: - handling and filling refrigerant cylinders. Refrigerant vapors or mist should not be inhaled because - they may cause heart irregularities and/or unconsciousness. Violations of the Clean Air Act? - falsifying or failing to keep required records; failing to reach required evacuation levels before opening or disposing of appliances; knowingly releasing CFC or HCFC refrigerants or their substitutes while repairing appliances. HFC refrigerants contain: - hydrogen, fluorine, carbon Which refrigerant contains an HCFC? - R-22 Recovery equipment that relies upon the pressure of the refrigerant in the appliance would be considered: - System-dependent Refrigerant that enters the compressor, under normal operating conditions, is a: - low pressure vapor. It is necessary to place a refrigerant label on: - a refrigerant cylinder which is being returned for reclaiming. Which refrigerant contains a CFC? - R-500 Use\_\_\_\_\_\_\_\_ to remove ice from a sight glass. - an alcohol spray. According to the EPA, an oil sample should be taken for which of the following reasons? - They system had a leak or a major component failure. The EPA requires the installation of a service aperture or process stub on all appliances using a class I or class II substance as a refrigerant. The main purpose of this requirement is to make it easier to: - recover refrigerant. Recycling and recovery equipment intended for use with air-conditioning and refrigeration equipment(except for small appliances) must be tested under: - ARI 740 Refrigerant entering the compressor of a refrigeration system is a: - superheated vapor. What is being done in the U.S. to stop damage to the stratospheric ozone layer? - capturing and ultimately eliminating use of chlorofluorocarbons. They type of oil that is most commonly used in stationary refrigeration applications with HFC-134a refrigerant is: - ester oil. The term used to describe the fact that a refrigerant blend has a range of boiling or condensing pints at a constant pressure is: - temperature glide. Which refrigerant contains a CFC? - R-12 Under EPA\'s regulations, what standard must reclaimed refrigerant meet before it can be resold? - ARI 700 An example of a HFC refrigerant is: - R-134a It is illegal to: - knowingly release any refrigerant during the service, maintenance, repair or disposal of appliances, with the exception of de minimis releases. Which type of refrigerant is the most harmful to stratospheric ozone? - CFC Refrigerant that enters the expansion or throttling device (also known as the metering device) is a: - liquid. Which of the following statements would be considered good service practices for conserving refrigerant? - recover or recycle refrigerant; keep systems tight; find and repair leaks Under the EPA \"safe disposal requirements\", the person responsible for making sure that the refrigerant has been removed from household refrigerators before they are disposed of is the: - final person in the disposal chain Which refrigerant listed below is a \"low-pressure refrigerant\" under EPA\'s refrigerant recycling regulations? - R-123 When moisture exists in an operating system, which of the following is the most likely to occur? - Acid will form Which of the following is a \"very high-pressure refrigerant\" under EPA\'s refrigerant recycling regulations? - R-13 When using nitrogen to pressurize a system, you should: - only charge with nitrogen vapor. Of the refrigerants listed below, which has the lowest ozone depletion potential? - R-134a When dealing with small systems, how many different refrigerants may be recovered into the same cylinder? - ONLY ONE When operating refrigerant recovery or recycling equipment, the following precautions should always be followed - wear safety glasses; wear protective gloves; follow all safety precautions for the equipment Of the refrigerants listed below, which types of refrigerants will not damage stratospheric ozone? - HFCs When evacuating a system, the hoses should b: - as short in length and as large in diameter as possible. Refrigerant leaves the condenser of an operating system as a: - high pressure liquid. If corrosion is found within the body of a relief valve, the valve must be: - replaced. The Clean Air Act: - sets a schedule for the phase out of CFC/HCFC production; prohibits venting of refrigerants; authorizes the EPA to set standards for recover of refrigerants. Measuring the system\'s final vacuum is always done with: - the system isolated and the vacuum pump off. A refillable refrigerant cylinder must never be filled to more than\_\_\_\_\_\_\_\_\_ of its capacity by weight: - 80% Of the refrigerants listed below, which refrigerant type have the highest ozone depletion potential? - CFCs This chemical was found in the upper stratosphere and that indicates that the ozone layer is being destroyed. - chlorine monoxide What factor(s) affects the speed of evacuation? - the size of the equipment being evacuated; the ambient temperature; the amount of moisture in the system HCFC refrigerants contain: - hydrogen, chlorine, fluorine, carbon When a system will not hold vacuum after is has been evacuated, then: - they system may be leaking. All recovery equipment currently being made is required to have: - an EPA approved certification label. The color code for approved refrigerant recovery cylinders is\_\_\_\_\_\_. - yellow tops and gray bodies When can you use a disposable cylinder to recover refrigerant? - never Which of the following is a \"high-pressure refrigerant\" under EPA\'s refrigerant recycling regulations? - R-22 After refrigerant liquid transfer between recovery unit and the system being emptied, you need to avoid trapping: - liquid refrigerant between service valves. You can determine safe pressure for leak testing a system from the: - low-side test-pressure data-plate value. If a technician has a system where some R-502 was added to an R-22 system. The technician should: - recover all the refrigerant into a separate tank. Ozone in the stratosphere above the earth consists of: - molecules of 3 oxygen atoms. The size (capacity) of the vacuum pump and the size of the suction line used will determine: - the length of dehydration time. According to the EPA, when dealing with customer complaints regarding additional costs due to refrigerant recovery efforts, the technician should: - explain the refrigerant recovery is necessary to protect human health and the environment; explain that refrigerant recovery is required by the Federal(and in some cases state and local)laws; inform the customer that professional service personnel are duty bound to follow the law and to protect the environment State and local governments can make state laws that: - follow the Clean Air Act/EPA regulations; contain stricter regulations than the Clean Air Act/EPA regulations. If an oil is hygroscopic it means that it: - readily absorbs moisture. When dehydrating a system, the system can be heated to: - decrease the dehydration time. The synthetic lubricant presently used with ternary blends containing HCFCs is: - alkylbenzene Ozone depletion in the stratosphere is what type of problem? - GLOBAL On a typical three port (three hose) manifold gauge, the center port is used for: - recovery, evacuation and charging. Ester based oils can be mixed with: - no other oils. CFCs will no longer be manufactured or imported into the United States after: - 1995 Which type of refrigerants are chlorine-free? - HFCs Refrigerant recovery during low ambient temperatures will: - slow the recovery process. \_\_\_\_\_\_\_ is the process of removing refrigerant in any condition from a system and storing it in an external container without necessarily testing or processing it in any way. - Recovering Containers designated \"refillable\" by DOT are used for transporting recovered pressurized refrigerant\_\_\_\_\_\_\_\_. - to meet safety requirements

Use Quizgecko on...
Browser
Browser