Lighting Requirements for Testing Booths
30 Questions
2 Views
3.3 Stars

Lighting Requirements for Testing Booths

Created by
@LawAbidingNonagon

Questions and Answers

What are the three main categories into which variables for sensory testing are grouped?

Test controls, product controls, panel controls

Why should the physical setting of the test area be designed as mentioned in the text?

To minimize the subjects' biases and eliminate non-product variables

What is the main reason for having a centrally located and comfortable sensory test area?

To maximize sensitivity of the subjects

What is one of the key characteristics of a sensory evaluation laboratory mentioned in the text?

<p>It should have a sample preparation room</p> Signup and view all the answers

What is the purpose of product controls in sensory testing?

<p>To ensure correct sample screening and preparation</p> Signup and view all the answers

Why is it important for a sensory evaluation laboratory to be free from odors and noise as stated in the text?

<p>To minimize distractions and maintain focus on product evaluation</p> Signup and view all the answers

Where should a laboratory for the preparation of samples be located according to the text?

<p>Adjacent to the testing area</p> Signup and view all the answers

What should be the ventilation condition in the preparation area as per the text?

<p>Well ventilated to remove odors</p> Signup and view all the answers

What kind of materials should be used for utensils and cutlery in sample preparation as indicated in the text?

<p>Materials that do not impart any odor or taste to the product</p> Signup and view all the answers

What is typically included in the preparation area along with any specialized equipment as per the text?

<p>Refrigerator, freezer, benches, kitchen range, ovens, etc.</p> Signup and view all the answers

What should be available for storage in the preparation area according to the text?

<p>Glassware, dishes, glasses, trays, etc.</p> Signup and view all the answers

Why should utensils and cutlery used in sample preparation not impart any odor or taste to the product based on the text?

<p>To prevent contamination of sensory evaluation</p> Signup and view all the answers

What is the minimum intensity of lighting required in the testing booths for effective evaluation?

<p>300 lux</p> Signup and view all the answers

Which correlated color temperature is considered desirable for the lights in the testing booths?

<p>6500 K</p> Signup and view all the answers

What special lighting device can be used to mask differences in color and appearance characteristics?

<p>Dimmer device</p> Signup and view all the answers

How large should each testing booth be to accommodate samples, utensils, sink, rinsing agents, and score sheet/card?

<p>0.9 m wide and 0.6 m deep</p> Signup and view all the answers

What height should the working space in the booth be to allow comfort to the evaluator?

<p>Appropriate height</p> Signup and view all the answers

What signaling system is devised for the evaluator to communicate readiness for a sample?

<p>Light bulb on the counter side</p> Signup and view all the answers

What is the purpose of the briefing room in a sensory evaluation facility?

<p>To assemble sensory evaluators and brief them about the project objectives</p> Signup and view all the answers

Why is it important for the booth area in a sensory facility to be isolated from the preparation area?

<p>To maintain cleanliness and professionalism in the testing area</p> Signup and view all the answers

Which factor is NOT mentioned as a critical consideration for a sensory laboratory design?

<p>Proximity to public transportation</p> Signup and view all the answers

What is the primary function of the briefing room in a sensory evaluation facility?

<p>Assembling sensory evaluators and providing project instructions</p> Signup and view all the answers

Why should the testing booth area in a sensory facility be comfortable but not too casual in appearance?

<p>To maintain a professional environment for sensory evaluation</p> Signup and view all the answers

What should be adjacent to the testing booths in a sensory evaluation facility?

<p>Briefing room</p> Signup and view all the answers

What is the purpose of separating entrance and exit areas for assessors in large facilities?

<p>To prevent unwanted exchange of information</p> Signup and view all the answers

Why is it important for the office facilities to be within view of the panel booths?

<p>To monitor the testing process</p> Signup and view all the answers

What should be located within the entrance/exit area in a sensory evaluation facility?

<p>Desk for assessors to study sample identity</p> Signup and view all the answers

Why should equipment like computers and printers be at a sufficient distance from the panel booths?

<p>To maintain confidentiality and avoid distractions</p> Signup and view all the answers

What is one reason for having a waiting room with comfortable seats in the entrance/exit area?

<p>To provide a comfortable environment for non-employee panelists</p> Signup and view all the answers

What is the purpose of an office within a sensory evaluation facility?

<p>To provide a workspace for panel leaders</p> Signup and view all the answers

More Quizzes Like This

Lighting Up Plant Growth
5 questions

Lighting Up Plant Growth

PainlessIllumination avatar
PainlessIllumination
Lighting Fixtures Installation Quiz
12 questions
Use Quizgecko on...
Browser
Browser