Podcast
Questions and Answers
What should be checked on the facepiece of the SCBA to ensure proper function?
What should be checked on the facepiece of the SCBA to ensure proper function?
Which condition requires an SCBA cylinder to be evacuated and tested?
Which condition requires an SCBA cylinder to be evacuated and tested?
What does a LED flash every 2 seconds indicate on the PASS and HUD indicators?
What does a LED flash every 2 seconds indicate on the PASS and HUD indicators?
How should the air pressure indicators on an SCBA cylinder function relative to each other?
How should the air pressure indicators on an SCBA cylinder function relative to each other?
Signup and view all the answers
What is a critical consideration for the fiberglass wrap of an SCBA cylinder?
What is a critical consideration for the fiberglass wrap of an SCBA cylinder?
Signup and view all the answers
What type of damage should be checked for on the SCBA's low and high-pressure hoses?
What type of damage should be checked for on the SCBA's low and high-pressure hoses?
Signup and view all the answers
What feature should you check on the backpack of the SCBA for safety?
What feature should you check on the backpack of the SCBA for safety?
Signup and view all the answers
What is essential for the exhalation valve in SCBA maintenance?
What is essential for the exhalation valve in SCBA maintenance?
Signup and view all the answers
What is the final step when installing the cylinder in an SCBA?
What is the final step when installing the cylinder in an SCBA?
Signup and view all the answers
Which procedure must be followed for 'Buddy Breathing'?
Which procedure must be followed for 'Buddy Breathing'?
Signup and view all the answers
What is the primary reason for the daily inspection of SCBA equipment?
What is the primary reason for the daily inspection of SCBA equipment?
Signup and view all the answers
What type of maintenance can SCBA members perform on their equipment?
What type of maintenance can SCBA members perform on their equipment?
Signup and view all the answers
What should be done if the low pressure hose is disconnected during use?
What should be done if the low pressure hose is disconnected during use?
Signup and view all the answers
Which component should be primarily inspected for deterioration in an SCBA?
Which component should be primarily inspected for deterioration in an SCBA?
Signup and view all the answers
How should the adjustment buckle be positioned for proper installation?
How should the adjustment buckle be positioned for proper installation?
Signup and view all the answers
What is the correct action to take when a member is out of air during an emergency?
What is the correct action to take when a member is out of air during an emergency?
Signup and view all the answers
What should the needle on the pressure gauge symbolize when preparing the SCBA?
What should the needle on the pressure gauge symbolize when preparing the SCBA?
Signup and view all the answers
What is the purpose of performing a seal and exhalation valve check on the facepiece?
What is the purpose of performing a seal and exhalation valve check on the facepiece?
Signup and view all the answers
Which procedure indicates that the 'PASS' alarm is working properly?
Which procedure indicates that the 'PASS' alarm is working properly?
Signup and view all the answers
What is the function of the bypass valve when preparing the SCBA?
What is the function of the bypass valve when preparing the SCBA?
Signup and view all the answers
During the inspection of the SCBA, what indicates a potential leak in the system?
During the inspection of the SCBA, what indicates a potential leak in the system?
Signup and view all the answers
Which action is necessary for cleaning the facepiece of the SCBA?
Which action is necessary for cleaning the facepiece of the SCBA?
Signup and view all the answers
What does a working Heads-Up Display (HUD) indicate?
What does a working Heads-Up Display (HUD) indicate?
Signup and view all the answers
How is the interaction of the regulator and air cylinder connection repaired?
How is the interaction of the regulator and air cylinder connection repaired?
Signup and view all the answers
Study Notes
SCBA Operations and Maintenance
- PASS (Personal Alert Safety System) will flash and emit audible alarms.
- Ensure pressure gauge needle is in the green (FULL) zone before use.
- Facepiece must be donned, and seal and exhalation valve checks performed.
- Attach second stage regulator to the facepiece; first breath activation should create positive pressure without excessive free flow.
- Check the Heads-Up Display (HUD) for full cylinder pressure, indicated by all four green LEDs lit.
- Close air cylinder valve; monitor pressure gauge for 20 seconds for any drop indicating leaks.
- A drop in PSI may signal a malfunction requiring repairs to the "O" ring at the regulator/cylinder connection.
- Open the bypass valve slowly; observe for the warbling whistle alarm activation between 1035 to 1215 PSI.
- The audible alarm sounds until pressure drops below 200 PSI.
Cleaning Procedures
- Use warm water and mild detergent to create a cleaning solution for the facepiece.
- Immerse the facepiece in the solution and gently clean with a soft brush.
- Ensure all parts, particularly the lens and regulator connection, are cleaned thoroughly and free of contaminants.
- Inspect facepiece for tears, proper function, and ensure it has no leaks or sticking valves.
- Low and high-pressure hoses must be checked for integrity and function.
- Examine the exterior of the compressed air cylinder for any damage; evacuate and test if found defective.
- Replace the air cylinder if the gauge reads below 4000 PSI on the digital pressure gauge.
- Backpack components should be checked for fraying, corroded buckles, and overall functionality.
- Battery status indicators for PASS and HUD should be checked; an LED flash every 10 seconds indicates full battery, while every 2 seconds indicates low battery.
Emergency Breathing Procedures
- "Buddy Breathing" allows an out-of-air member to share a breathing supply with a donor.
- The out-of-air member retrieves the buddy breathing hose from their left hip pouch.
- Proper connection to the donor's buddy breathing "Y" block is essential; practice with gloved hands ensures proficiency.
- The donor must lead both individuals to safety immediately after initiating the connection.
Inspection and Maintenance Requirements
- SCBA must be inspected daily and after each use for defects or damage.
- Focus on careful maintenance, cleaning, storage, and transportation to prevent foreign matter-related damage.
- Repairs limited to battery and "O" ring replacements are permissible; all other repairs must be handled by certified personnel.
- Inspect facepiece skirt and headstrap for tears, pliability, and overall condition to ensure safety and functionality.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz covers essential steps for using and checking Self-Contained Breathing Apparatus (SCBA) equipment. Understand the importance of proper equipment checks, facepiece sealing, and performance of activation procedures. Ideal for training in firefighting and emergency response scenarios.