Podcast
Questions and Answers
What is the primary purpose of shutting off nozzles after attachment to hose lines?
What is the primary purpose of shutting off nozzles after attachment to hose lines?
When should hose lines be charged with water while being operated from heights?
When should hose lines be charged with water while being operated from heights?
What is the maximum angle for horizontal movement of hose streams from ladders?
What is the maximum angle for horizontal movement of hose streams from ladders?
What is a critical safety consideration when using hose streams from ladders?
What is a critical safety consideration when using hose streams from ladders?
Signup and view all the answers
What action should be taken before lowering hose from heights?
What action should be taken before lowering hose from heights?
Signup and view all the answers
Why should members not leave one person alone on the nozzle inside a structure?
Why should members not leave one person alone on the nozzle inside a structure?
Signup and view all the answers
Which of the following procedures is advised for the safe use of hose lines?
Which of the following procedures is advised for the safe use of hose lines?
Signup and view all the answers
What should be done to relieve the strain from the hose line during operations?
What should be done to relieve the strain from the hose line during operations?
Signup and view all the answers
What is the maximum pressure at which one-inch double jacketed hose should be tested?
What is the maximum pressure at which one-inch double jacketed hose should be tested?
Signup and view all the answers
How often should fire hose be tested?
How often should fire hose be tested?
Signup and view all the answers
When a section of hose is determined to be unreliable, what should be done?
When a section of hose is determined to be unreliable, what should be done?
Signup and view all the answers
Which hose type requires a maximum test pressure of 300 psi?
Which hose type requires a maximum test pressure of 300 psi?
Signup and view all the answers
What is the recommended procedure before testing a hose under pressure?
What is the recommended procedure before testing a hose under pressure?
Signup and view all the answers
What should be done after attaching the shut-off butt during hose testing?
What should be done after attaching the shut-off butt during hose testing?
Signup and view all the answers
What type of tag should be attached to a hose needing repair?
What type of tag should be attached to a hose needing repair?
Signup and view all the answers
What is the recommended maximum length of hose to be laid out from the pump outlet during testing?
What is the recommended maximum length of hose to be laid out from the pump outlet during testing?
Signup and view all the answers
What is the correct position for the first fold of the hose when securing it to the SCBA bottle?
What is the correct position for the first fold of the hose when securing it to the SCBA bottle?
Signup and view all the answers
When securing the hose to the SCBA bottle, how should the folds be arranged?
When securing the hose to the SCBA bottle, how should the folds be arranged?
Signup and view all the answers
Which strap should be placed where the hose forms the radius of the 'U'?
Which strap should be placed where the hose forms the radius of the 'U'?
Signup and view all the answers
How should the nozzle be secured when it reaches the last fold of the hose?
How should the nozzle be secured when it reaches the last fold of the hose?
Signup and view all the answers
What is the minimum length for the nylon straps used in securing the hose?
What is the minimum length for the nylon straps used in securing the hose?
Signup and view all the answers
Where should the second and third nylon straps be placed?
Where should the second and third nylon straps be placed?
Signup and view all the answers
What is the purpose of the fourth and fifth nylon straps in the hose securing process?
What is the purpose of the fourth and fifth nylon straps in the hose securing process?
Signup and view all the answers
What is the correct procedure for securing the buckles of the nylon straps?
What is the correct procedure for securing the buckles of the nylon straps?
Signup and view all the answers
Study Notes
SCBA Bottle Setup and Hose Handling
- First fold of hose should be positioned against the SCBA bottle with the female coupling about 10 inches below the shut-off valve.
- Alternate folds should form a loose "U" shape against the bottle, ensuring they remain even.
- Upon reaching the male coupling, attach the nozzle and shut off. Invert the last fold to protect the nozzle behind the final fold of the pack.
- Secure the first nylon strap around the radius of the "U," utilizing straps at least 24 inches long with the buckle in a safe location.
- Place the second and third nylon straps around the hose opposite each other, positioned at the middle of the SCBA bottle, and secure buckles safely.
- The fourth and fifth nylon straps should be placed approximately 8 inches from the end of the hose packs, ensuring one strap goes through the nozzle bale.
Safe Use of Hose Lines
- Nozzles must be shut off after attachment or whenever the flow ceases for safety.
- Charge hose lines from heights only after securing them in position.
- Clear and secure hoses leading to upper floors from ladders to ensure safe operation.
- Water should be drained at street level before lowering hoses from elevated positions.
- Avoid directing water streams at individuals or premises unnecessarily.
- Ensure care during hose stream use from ladders, limiting horizontal movement to 15 degrees from an "in-line" position.
Backing Up the Nozzle
- Backing up the nozzle relieves strain caused by the reactionary force of water streams.
- Maintain staggered positions among members holding the hose, keeping hose lines clear of sharp bends.
- Notify the member at the nozzle before leaving the hose line, and ensure that no one is left alone on the nozzle.
- If a hose needs repairs, mark the damaged area with black tape and roll the hose with the female coupling forming the core.
- Use an F-175 tag describing the issue for easier identification and repair.
Hose Testing Procedures
- Station Commanders must ensure all rubber-lined hoses are tested annually, especially new and repaired hoses.
- Testing should occur immediately after receipt or repairs.
- Maximum interval between tests is 12 months.
- One-inch double jacketed hoses are tested at 400 psi, while other rubber-lined hoses are tested at 300 psi.
- For testing, lay out hoses from the pump without kinks, up to a maximum length of 300 feet, and attach a shut-off butt to minimize hazards.
- Bleed off air by opening the shut-off, elevating above discharge level, and filling the hose with water, controlling flow carefully.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz focuses on the proper techniques for folding hose against a 45-minute SCBA bottle. Learn the correct positioning and method to ensure efficient storage and handling. Test your knowledge on best practices and safety protocols.