Who is responsible for ensuring crew members are adequately equipped with respiratory protection equipment?

  • Training Division
  • District Chiefs
  • Company Officers (correct)
  • Mechanical Division
  • What is the purpose of this guideline?

  • To administer the TFS Annual SCBA Certification Program
  • To ensure all personnel are trained on SCBA usage
  • To provide a guideline for inspecting, testing, maintaining, repairing, and wearing of SCBA (correct)
  • To assign SCBA to each crew member
  • Who maintains records of minor field repairs conducted by Air/Light Unit personnel?

  • Company Officers
  • District Chiefs
  • Mechanical Division (correct)
  • Training Division
  • Who is responsible for administering this guideline in its entirety?

    <p>District Chiefs</p> Signup and view all the answers

    What is the responsibility of the Training Division?

    <p>Keeping records of the TFS Annual SCBA Certification Program</p> Signup and view all the answers

    When should personnel perform the daily inspection and test on their assigned SCBA?

    <p>Immediately upon relieving the off-duty shift</p> Signup and view all the answers

    What type of respirators are also covered by this guideline?

    <p>Air Line Respirators</p> Signup and view all the answers

    Who is responsible for repairing all SCBA?

    <p>Mechanical Division</p> Signup and view all the answers

    Who is responsible for ensuring SCBA inspections are conducted at the beginning of each shift?

    <p>The Company Officer</p> Signup and view all the answers

    How frequently must MSA 4500 SCBA cylinders be hydrostatically tested?

    <p>Every five years</p> Signup and view all the answers

    Which personnel are required to conduct the daily inspection of unassigned SCBA units on the vehicle?

    <p>The Driver of the apparatus</p> Signup and view all the answers

    Who conducts the annual inspection and testing of SCBA assigned to each apparatus?

    <p>The Mechanical Division</p> Signup and view all the answers

    What should be written in the SCBA Inspection Log if an apparatus is out of service when a platoon reports for duty?

    <p>Out of Service</p> Signup and view all the answers

    Who is responsible for inspecting unassigned SCBA on fireboats daily?

    <p>The Marine Fire Ops Captain</p> Signup and view all the answers

    How often are personally issued SCBA facepieces flow tested?

    <p>Every two years</p> Signup and view all the answers

    What safety equipment should personnel wear when entering an incident that requires respiratory protection?

    <p>SCBA</p> Signup and view all the answers

    Study Notes

    Purpose and Responsibility

    • The purpose of this guideline is to instruct Toronto Fire Services (TFS) personnel on inspecting, testing, maintaining, repairing, and wearing Self-Contained Breathing Apparatus (SCBA).
    • All personnel are responsible for properly inspecting, maintaining, and using assigned personal protective equipment including SCBA.
    • Company Officers are responsible for the safety of their crew and ensuring they are adequately equipped with respiratory protection equipment.

    Guidelines

    • Each crew member aboard the apparatus shall be assigned a SCBA, and this guideline also applies to Air Line Respirators (carried on Squads).
    • All personnel expected to respond to emergency situations shall meet the criteria of the TFS Annual SCBA Certification Program.

    Inspection and Test

    • Personnel shall perform daily inspections and tests on their assigned SCBA immediately upon relieving the off-duty shift, and after each use.
    • The Company Officer shall ensure SCBA inspections are carried out promptly at the beginning of each shift and after each use.
    • Spare SCBA units and RIT Kits shall be inspected daily by the Driver of the apparatus.

    Inspection and Hydrostatic Testing

    • The Mechanical Division shall test all SCBA annually according to manufacturer’s published methods.

    • The Mechanical Division shall conduct inspection and testing of SCBA assigned to each apparatus, annually.

    • All MSA 4500 SCBA cylinders shall be hydrostatic tested every five years at an approved facility, and MSA 3000 confined space escape cylinders shall be hydrostatically tested every five years.

    • The Mechanical Division shall conduct the following:

      (a) Inspection and testing of SCBA assigned to each apparatus, annually.

      (b) Inspection and flow testing of personally issued SCBA facepieces, every two years.

      (c) All repairs, firmware, maintenance, investigations deemed necessary and warranty claims.

    Donning

    • Personnel shall wear SCBA when entering any incident that requires respiratory protection.
    • SCBA may be donned while responding to alarms provided that safety is not compromised.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the guidelines for inspecting, testing, maintaining, repairing, and wearing Self-Contained Breathing Apparatus (SCBA) for Toronto Fire Services personnel.

    More Like This

    SCBA Usage and Safety Procedures
    24 questions
    Saving our own
    727 questions

    Saving our own

    ProdigiousJasper737 avatar
    ProdigiousJasper737
    Use Quizgecko on...
    Browser
    Browser