Podcast
Questions and Answers
Who is responsible for ensuring crew members are adequately equipped with respiratory protection equipment?
Who is responsible for ensuring crew members are adequately equipped with respiratory protection equipment?
What is the purpose of this guideline?
What is the purpose of this guideline?
Who maintains records of minor field repairs conducted by Air/Light Unit personnel?
Who maintains records of minor field repairs conducted by Air/Light Unit personnel?
Who is responsible for administering this guideline in its entirety?
Who is responsible for administering this guideline in its entirety?
Signup and view all the answers
What is the responsibility of the Training Division?
What is the responsibility of the Training Division?
Signup and view all the answers
When should personnel perform the daily inspection and test on their assigned SCBA?
When should personnel perform the daily inspection and test on their assigned SCBA?
Signup and view all the answers
What type of respirators are also covered by this guideline?
What type of respirators are also covered by this guideline?
Signup and view all the answers
Who is responsible for repairing all SCBA?
Who is responsible for repairing all SCBA?
Signup and view all the answers
Who is responsible for ensuring SCBA inspections are conducted at the beginning of each shift?
Who is responsible for ensuring SCBA inspections are conducted at the beginning of each shift?
Signup and view all the answers
How frequently must MSA 4500 SCBA cylinders be hydrostatically tested?
How frequently must MSA 4500 SCBA cylinders be hydrostatically tested?
Signup and view all the answers
Which personnel are required to conduct the daily inspection of unassigned SCBA units on the vehicle?
Which personnel are required to conduct the daily inspection of unassigned SCBA units on the vehicle?
Signup and view all the answers
Who conducts the annual inspection and testing of SCBA assigned to each apparatus?
Who conducts the annual inspection and testing of SCBA assigned to each apparatus?
Signup and view all the answers
What should be written in the SCBA Inspection Log if an apparatus is out of service when a platoon reports for duty?
What should be written in the SCBA Inspection Log if an apparatus is out of service when a platoon reports for duty?
Signup and view all the answers
Who is responsible for inspecting unassigned SCBA on fireboats daily?
Who is responsible for inspecting unassigned SCBA on fireboats daily?
Signup and view all the answers
How often are personally issued SCBA facepieces flow tested?
How often are personally issued SCBA facepieces flow tested?
Signup and view all the answers
What safety equipment should personnel wear when entering an incident that requires respiratory protection?
What safety equipment should personnel wear when entering an incident that requires respiratory protection?
Signup and view all the answers
Study Notes
Purpose and Responsibility
- The purpose of this guideline is to instruct Toronto Fire Services (TFS) personnel on inspecting, testing, maintaining, repairing, and wearing Self-Contained Breathing Apparatus (SCBA).
- All personnel are responsible for properly inspecting, maintaining, and using assigned personal protective equipment including SCBA.
- Company Officers are responsible for the safety of their crew and ensuring they are adequately equipped with respiratory protection equipment.
Guidelines
- Each crew member aboard the apparatus shall be assigned a SCBA, and this guideline also applies to Air Line Respirators (carried on Squads).
- All personnel expected to respond to emergency situations shall meet the criteria of the TFS Annual SCBA Certification Program.
Inspection and Test
- Personnel shall perform daily inspections and tests on their assigned SCBA immediately upon relieving the off-duty shift, and after each use.
- The Company Officer shall ensure SCBA inspections are carried out promptly at the beginning of each shift and after each use.
- Spare SCBA units and RIT Kits shall be inspected daily by the Driver of the apparatus.
Inspection and Hydrostatic Testing
-
The Mechanical Division shall test all SCBA annually according to manufacturer’s published methods.
-
The Mechanical Division shall conduct inspection and testing of SCBA assigned to each apparatus, annually.
-
All MSA 4500 SCBA cylinders shall be hydrostatic tested every five years at an approved facility, and MSA 3000 confined space escape cylinders shall be hydrostatically tested every five years.
-
The Mechanical Division shall conduct the following:
(a) Inspection and testing of SCBA assigned to each apparatus, annually.
(b) Inspection and flow testing of personally issued SCBA facepieces, every two years.
(c) All repairs, firmware, maintenance, investigations deemed necessary and warranty claims.
Donning
- Personnel shall wear SCBA when entering any incident that requires respiratory protection.
- SCBA may be donned while responding to alarms provided that safety is not compromised.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
This quiz covers the guidelines for inspecting, testing, maintaining, repairing, and wearing Self-Contained Breathing Apparatus (SCBA) for Toronto Fire Services personnel.