SCBA and Integrated PASS Device Use
22 Questions
0 Views

SCBA and Integrated PASS Device Use

Created by
@LighterElm

Questions and Answers

When are SCBAs with integrated PASS devices mandatory to use?

  • In areas with normal atmospheric conditions
  • Only during overhaul operations
  • When the atmosphere is hazardous, suspected of being hazardous, or may rapidly become hazardous (correct)
  • When working above ground level or outside confined spaces
  • What is the primary reason for using SCBAs during overhaul operations?

  • To ensure the atmosphere is safe for breathing (correct)
  • To protect against hazardous materials
  • To monitor the atmosphere for oxygen levels
  • To comply with NIMS regulations
  • In what situations are personnel exempt from using SCBAs?

  • When the Quattro Sensit monitor or equivalent monitor indicates a safe atmosphere
  • During overhaul operations when the atmosphere is deemed safe
  • When working in areas with hazardous atmospheres
  • When working below ground level or inside confined spaces with a safe atmosphere (correct)
  • What type of monitor is used to determine the safety of the atmosphere?

    <p>Quattro Sensit monitor or equivalent monitor</p> Signup and view all the answers

    What is the consequence of removing SCBAs prematurely during overhaul operations?

    <p>Personnel may be exposed to hazardous atmospheres</p> Signup and view all the answers

    What is the primary purpose of the integrated PASS device?

    <p>To alert others in the event of an emergency</p> Signup and view all the answers

    Who is responsible for determining when it is safe to remove SCBAs during overhaul operations?

    <p>The personnel using the SCBAs</p> Signup and view all the answers

    What is the re-evaluation date for this SOG?

    <p>January 1, 2025</p> Signup and view all the answers

    Which of the following is NOT allowed to be used during SCBA use?

    <p>Spectacles with temple bars that pass through the face piece-to-face seal area</p> Signup and view all the answers

    What is the minimum grade requirement for compressed gaseous breathing air used in SCBA?

    <p>D</p> Signup and view all the answers

    Who is authorized to perform maintenance on SCBA other than daily checks and cleaning?

    <p>Certified personnel</p> Signup and view all the answers

    What standard must all SCBA's meet at the time of purchase?

    <p>NFPA Standard 1981</p> Signup and view all the answers

    What is the maximum allowed period between hydrostatic tests of SCBA cylinders?

    <p>As specified by the manufacturer</p> Signup and view all the answers

    Which of the following statements about SCBA use is TRUE?

    <p>The SCBA face piece must seal perfectly with the face to be effective.</p> Signup and view all the answers

    What is the maximum permissible CO level for a safe atmosphere?

    <p>35 parts per million</p> Signup and view all the answers

    Which condition regarding facial hair is stated for members required to use SCBA?

    <p>Facial hair is prohibited at sealing points of the SCBA face piece.</p> Signup and view all the answers

    What percentage of oxygen is considered the minimum acceptable level for safety?

    <p>19.5%</p> Signup and view all the answers

    How often must members utilizing SCBA undergo a quantitative fit test?

    <p>Annually</p> Signup and view all the answers

    Who is responsible for ensuring personnel using SCBA are accounted for during operations?

    <p>One member of the NIMS group</p> Signup and view all the answers

    What is the maximum permissible concentration of H2S in a safe atmosphere?

    <p>10 parts per million</p> Signup and view all the answers

    When wearing corrective lenses with SCBA, what specific requirement must be met?

    <p>Spectacles must be fitted without interfering with the seal.</p> Signup and view all the answers

    Why is it critical for members using SCBAs to operate in teams?

    <p>To ensure constant communication and assistance during emergencies.</p> Signup and view all the answers

    Study Notes

    SCBA and Integrated PASS Device Use

    • The Hoffman Estates Fire Department mandates the use of SCBAs with integrated PASS devices in areas with hazardous or oxygen-deficient atmospheres.
    • SCBAs must be used by all personnel in areas where the atmosphere is:
      • Hazardous
      • Suspected of being hazardous
      • May rapidly become hazardous
    • SCBAs are required for personnel working below ground level or inside a confined space unless the atmosphere can be established and maintained as safe.

    Safe Atmosphere Conditions

    • An atmosphere is considered safe if it meets the following NIOSH permissible exposure limits:
      • O2 Level: not below 19.5% or greater than 23.5%
      • CO Level: not greater than 35 parts per million
      • H2S: not greater than 10 parts per million
      • HCN: not greater than 4.7 parts per million

    SCBA Operations and Training

    • Members using SCBAs must operate in teams of two or more, maintaining close proximity and communication.
    • At least one member of the NIMS group is responsible for monitoring personnel using SCBAs, their location, and function.
    • All personnel must be thoroughly trained in SCBA use, care, and maintenance, meeting minimum requirements set by the Training Officer.
    • Members must be certified to meet annual certification requirements established by the Department.

    SCBA Face Piece and Fit Testing

    • The face piece must fit the user as close as possible, with a nose cup fitted to the face piece.
    • Annual quantitative fit testing is required to ensure a proper fit.
    • Facial hair that interferes with the face piece seal or valve function is prohibited.
    • Corrective lenses must be fitted inside the face piece to maintain the face piece-to-face seal.

    SCBA Maintenance and Requirements

    • SCBA cylinders must be hydrostatically tested within the periods specified by the manufacturer and applicable government agencies.
    • Compressed gaseous breathing air must meet the Compressed Gas Association G-7.1 requirements, with a minimum of Grade "D".
    • All SCBAs must have maintenance performed as set by the manufacturer's specifications, with certified personnel performing maintenance other than daily checks and cleaning.
    • All SCBAs must meet the requirements of NFPA Standard 1981 at the time of purchase.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the safety guidelines for using SCBA and Integrated PASS devices in firefighting operations, based on the Hoffman Estates Fire Department's Standard Operating Guidelines.

    More Quizzes Like This

    E-SCBA Part 1
    16 questions

    E-SCBA Part 1

    ProtectiveJackalope4164 avatar
    ProtectiveJackalope4164
    Firefighting Equipment: 1.78" Hose
    28 questions
    Use Quizgecko on...
    Browser
    Browser