Online Oil Analysis: MSENSE® DGA 9
48 Questions
0 Views

Online Oil Analysis: MSENSE® DGA 9

Created by
@FunnyTriumph

Questions and Answers

What is the primary function of the MSENSE® DGA 9 system?

  • To analyze physical properties of oil
  • To determine the viscosity of oil
  • To monitor temperature fluctuations in oil
  • To measure moisture and gases dissolved in oil (correct)
  • Which gas is not analyzed by the MSENSE® DGA 9?

  • Nitrogen (N2) (correct)
  • Methane (CH4)
  • Carbon monoxide (CO)
  • Hydrogen (H2)
  • Which of the following companies manufactures the MSENSE® DGA 9?

  • EMH Energie-Messtechnik GmbH
  • Maschinenfabrik Reinhausen GmbH (correct)
  • Landis+Gyr AG
  • MTE Meter Test Equipment AG
  • How is the MSENSE® DGA 9 described in terms of its installation?

    <p>Permanently installed</p> Signup and view all the answers

    What component can be measured by the MSENSE® DGA 9 along with gases?

    <p>Moisture in oil</p> Signup and view all the answers

    What is a limitation mentioned regarding the information provided by MTE Meter Test Equipment AG?

    <p>Information is not legally binding</p> Signup and view all the answers

    Which of the following gases is specifically mentioned as a component of combustion analysis?

    <p>Carbon dioxide (CO2)</p> Signup and view all the answers

    Which company handles inquiries regarding the MSENSE® DGA 9?

    <p>Maschinenfabrik Reinhausen GmbH</p> Signup and view all the answers

    What is the maximum power consumption of the product?

    <p>600 VA</p> Signup and view all the answers

    Which power supply option allows for a wider input voltage range?

    <p>230 V AC</p> Signup and view all the answers

    What is the weight of the product?

    <p>15 kg</p> Signup and view all the answers

    Which communication protocol is standard for this product?

    <p>RS 485 Modbus RTU</p> Signup and view all the answers

    What is the typical storage temperature range for the product?

    <p>-20°C to +80°C</p> Signup and view all the answers

    Which valve connection is standard for this product?

    <p>G 1½&quot; DIN ISO 228-1</p> Signup and view all the answers

    What is the maximum switching capacity of the relay outputs?

    <p>2 A / 60 W</p> Signup and view all the answers

    Which of the following gases has the highest measured concentration range?

    <p>Carbon dioxide (CO2)</p> Signup and view all the answers

    What is the protection class rating of the device?

    <p>IP 55</p> Signup and view all the answers

    What is the accuracy of measuring moisture in mineral oil?

    <p>± 3%</p> Signup and view all the answers

    What type of display does the device feature?

    <p>Graphic LCD</p> Signup and view all the answers

    What is the operating temperature limit of the device?

    <p>65°C</p> Signup and view all the answers

    How many analog outputs does the device have?

    <p>10</p> Signup and view all the answers

    Which gas is incorrectly matched with its measured range?

    <p>Ethylene (C2H4) - 0...5,000 ppm</p> Signup and view all the answers

    What is the minimum permissible oil inlet pressure?

    <p>Negative pressure permissible</p> Signup and view all the answers

    The MSENSE® DGA 9 can analyze gas concentrations such as hydrogen (H2) and carbon monoxide (CO).

    <p>True</p> Signup and view all the answers

    The MSENSE® DGA 9 is only capable of measuring gas concentrations without any other parameters.

    <p>False</p> Signup and view all the answers

    EMH Energie-Messtechnik GmbH is responsible for the manufacturing of the MSENSE® DGA 9.

    <p>True</p> Signup and view all the answers

    Oxygen (O2) is one of the gases that the MSENSE® DGA 9 is capable of analyzing.

    <p>True</p> Signup and view all the answers

    The MSENSE® DGA 9 has been approved for use in mobile applications.

    <p>False</p> Signup and view all the answers

    The MSENSE® DGA 9 is capable of measuring only one type of gas at a time.

    <p>False</p> Signup and view all the answers

    The analysis system can measure acetylene (C2H2) and ethylene (C2H4) gases.

    <p>True</p> Signup and view all the answers

    MTE Meter Test Equipment AG is responsible for customer service inquiries regarding the MSENSE® DGA 9.

    <p>False</p> Signup and view all the answers

    The product's operating temperature range is from -20°C to +90°C.

    <p>False</p> Signup and view all the answers

    The housing material of the product is made of plastic.

    <p>False</p> Signup and view all the answers

    A standard communication option for the product is Ethernet RJ45.

    <p>True</p> Signup and view all the answers

    The maximum power consumption of the product is 600 VA.

    <p>True</p> Signup and view all the answers

    The weight of the product is approximately 20 kg.

    <p>False</p> Signup and view all the answers

    The valve connection standard for the product is G 2 ½" DIN ISO 228-1.

    <p>False</p> Signup and view all the answers

    The device can operate at ambient temperatures up to +55°C.

    <p>True</p> Signup and view all the answers

    The product supports DNP3 protocol as a standard communication option.

    <p>False</p> Signup and view all the answers

    The MSENSE® DGA 9 can measure moisture in mineral oil at a range of 0…100 ppm.

    <p>True</p> Signup and view all the answers

    The device has a maximum measured concentration range of 0...50,000 ppm for Acetylene (C2H2).

    <p>False</p> Signup and view all the answers

    The MSENSE® DGA 9 features 10 relay outputs with a maximum switching capacity of 220 VDC/VAC.

    <p>True</p> Signup and view all the answers

    The accuracy for measuring Carbon Dioxide (CO2) is ± 15% or ± 25 ppm.

    <p>False</p> Signup and view all the answers

    The MSENSE® DGA 9 device operates within an ambient temperature of +65°C.

    <p>False</p> Signup and view all the answers

    The device has been CE certified for safety standards.

    <p>True</p> Signup and view all the answers

    The graphical LCD of the device is operated with 12 keys.

    <p>False</p> Signup and view all the answers

    The maximum oil inlet pressure for the MSENSE® DGA 9 is 300 kPa.

    <p>True</p> Signup and view all the answers

    The device is protected under IEC 61010-1:2002 for insulation protection.

    <p>True</p> Signup and view all the answers

    Study Notes

    General Information

    • MSENSE® DGA 9 is a multi gas online DGA analysis system for oil.
    • Manufactured by Maschinenfabrik Reinhausen GmbH and EMH Energie-Messtechnik GmbH.
    • Contact for inquiries: [email protected], [email protected].

    Measurement Capabilities

    • Measures moisture in oil (H2O) and key dissolved gases:
      • Hydrogen (H2)
      • Carbon Monoxide (CO)
      • Carbon Dioxide (CO2)
      • Acetylene (C2H2)
      • Ethylene (C2H4)
      • Methane (CH4)
      • Ethane (C2H6)
      • Oxygen (O2)

    Technical Specifications

    • Power Supply:
      • Options for 230 V AC and 120 V AC with tolerances of -20% to +15%.
    • Valve Connection Types:
      • G 1½" DIN ISO 228-1
      • 1½” NPT ANSI B 1.20.1
    • Communication Interfaces:
      • RS 485 Modbus RTU, TCP (standard)
      • Ethernet RJ45 or fiber optics (standard/optional)
      • DNP3 modem RS-485 (optional)
      • IEC 61850 modem RJ45 or fiber (optional)

    Physical Attributes

    • Dimensions: Width 263 mm, Height 263 mm, Depth 327.5 mm
    • Weight: Approximately 15 kg
    • Housing: Aluminum
    • Operating Temperature Range:
      • Ambient: -55°C to +55°C
      • Oil: -20°C to +90°C
    • Storage Temperature: -20°C to +65°C
    • Oil Inlet Pressure: 0 - 300 kPa (negative pressure permissible)

    Safety and Compliance

    • CE certified, meeting safety standards.
    • Insulation protection according to IEC 61010-1:2002.
    • Protection class rated at IP 55.

    Output Specifications

    • 10 Analog Outputs (0/4–20 mA) for various gases and moisture levels:
      • Hydrogen (H2)
      • Acetylene (C2H2)
      • Ethylene (C2H4)
      • Carbon Monoxide (CO)
      • Oil Moisture (H2O)
      • Carbon Dioxide (CO2)
      • Ethane (C2H6)
      • Methane (CH4)
      • Oxygen (O2)
    • 10 Relay Outputs with a maximum switching capacity of 220 VDC/VAC / 2 A / 60 W.

    Measurement Ranges and Accuracy

    • Hydrogen (H2): 0-10,000 ppm, accuracy ±15% or ±25 ppm.
    • Carbon Monoxide (CO): 0-10,000 ppm, accuracy ±20% or ±25 ppm.
    • Carbon Dioxide (CO2): 0-20,000 ppm, accuracy ±20% or ±25 ppm.
    • Methane (CH4): 0-5,000 ppm, accuracy ±20% or ±25 ppm.
    • Acetylene (C2H2): 0-10,000 ppm, accuracy ±20% or ±5 ppm.
    • Ethylene (C2H4): 0-10,000 ppm, accuracy ±20% or ±10 ppm.
    • Ethane (C2H6): 0-10,000 ppm, accuracy ±20% or ±15 ppm.
    • Oxygen (O2): 0-50,000 ppm, accuracy ±10% or ±1000 ppm.
    • Moisture in mineral oil (H2O): 0-100%, accuracy ±3%.
    • Measurement accuracy is dependent on ambient and oil temperatures.

    User Interface

    • Controls:
      • Graphical LCD display for user interaction.
      • 17 operational keys for functionality and settings.

    General Information

    • MSENSE® DGA 9 is a multi gas online DGA analysis system for oil.
    • Manufactured by Maschinenfabrik Reinhausen GmbH and EMH Energie-Messtechnik GmbH.
    • Contact for inquiries: [email protected], [email protected].

    Measurement Capabilities

    • Measures moisture in oil (H2O) and key dissolved gases:
      • Hydrogen (H2)
      • Carbon Monoxide (CO)
      • Carbon Dioxide (CO2)
      • Acetylene (C2H2)
      • Ethylene (C2H4)
      • Methane (CH4)
      • Ethane (C2H6)
      • Oxygen (O2)

    Technical Specifications

    • Power Supply:
      • Options for 230 V AC and 120 V AC with tolerances of -20% to +15%.
    • Valve Connection Types:
      • G 1½" DIN ISO 228-1
      • 1½” NPT ANSI B 1.20.1
    • Communication Interfaces:
      • RS 485 Modbus RTU, TCP (standard)
      • Ethernet RJ45 or fiber optics (standard/optional)
      • DNP3 modem RS-485 (optional)
      • IEC 61850 modem RJ45 or fiber (optional)

    Physical Attributes

    • Dimensions: Width 263 mm, Height 263 mm, Depth 327.5 mm
    • Weight: Approximately 15 kg
    • Housing: Aluminum
    • Operating Temperature Range:
      • Ambient: -55°C to +55°C
      • Oil: -20°C to +90°C
    • Storage Temperature: -20°C to +65°C
    • Oil Inlet Pressure: 0 - 300 kPa (negative pressure permissible)

    Safety and Compliance

    • CE certified, meeting safety standards.
    • Insulation protection according to IEC 61010-1:2002.
    • Protection class rated at IP 55.

    Output Specifications

    • 10 Analog Outputs (0/4–20 mA) for various gases and moisture levels:
      • Hydrogen (H2)
      • Acetylene (C2H2)
      • Ethylene (C2H4)
      • Carbon Monoxide (CO)
      • Oil Moisture (H2O)
      • Carbon Dioxide (CO2)
      • Ethane (C2H6)
      • Methane (CH4)
      • Oxygen (O2)
    • 10 Relay Outputs with a maximum switching capacity of 220 VDC/VAC / 2 A / 60 W.

    Measurement Ranges and Accuracy

    • Hydrogen (H2): 0-10,000 ppm, accuracy ±15% or ±25 ppm.
    • Carbon Monoxide (CO): 0-10,000 ppm, accuracy ±20% or ±25 ppm.
    • Carbon Dioxide (CO2): 0-20,000 ppm, accuracy ±20% or ±25 ppm.
    • Methane (CH4): 0-5,000 ppm, accuracy ±20% or ±25 ppm.
    • Acetylene (C2H2): 0-10,000 ppm, accuracy ±20% or ±5 ppm.
    • Ethylene (C2H4): 0-10,000 ppm, accuracy ±20% or ±10 ppm.
    • Ethane (C2H6): 0-10,000 ppm, accuracy ±20% or ±15 ppm.
    • Oxygen (O2): 0-50,000 ppm, accuracy ±10% or ±1000 ppm.
    • Moisture in mineral oil (H2O): 0-100%, accuracy ±3%.
    • Measurement accuracy is dependent on ambient and oil temperatures.

    User Interface

    • Controls:
      • Graphical LCD display for user interaction.
      • 17 operational keys for functionality and settings.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Explore the features and applications of the MSENSE® DGA 9, a product by Maschinenfabrik Reinhausen GmbH. This quiz provides insights into the technical specifications and operational details essential for effective oil analysis. Perfect for those involved in energy measurement and technical support.

    More Quizzes Like This

    Oil Analysis as a Diagnostic Tool
    100 questions
    MSENSE DGA 2/3 Overview Quiz
    50 questions
    Crude Oil Sample Analysis
    25 questions
    Use Quizgecko on...
    Browser
    Browser