Facility Maintenance Inspections Quiz
42 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What action should be taken if a cell's voltage is found to be below the prescribed value?

  • Document the findings for future reference
  • Perform a performance test
  • Replace the cell immediately (correct)
  • Monitor the voltage continuously
  • What is the minimum frequency for inspecting electronics in indoor locations?

  • Half yearly
  • Quarterly
  • Monthly
  • Yearly (correct)
  • What is the preferred earth resistance value during earthing checks?

  • Less than 5 ohms
  • Less than 1 ohm (correct)
  • Less than 0.5 ohms
  • Less than 3 ohms
  • How often should the DG set be inspected according to the section in charge's schedule?

    <p>Quarterly</p> Signup and view all the answers

    Which of the following is NOT a recommended check for the Diesel Generator Set?

    <p>Performing a fuel quality assessment</p> Signup and view all the answers

    Which of the following is NOT part of the yearly inspection for indoor equipment?

    <p>General upkeep of equipment</p> Signup and view all the answers

    During fire alarm system maintenance, what is an essential task to ensure functionality?

    <p>Cleaning the fire sensors</p> Signup and view all the answers

    What should be verified in relation to air conditioning systems?

    <p>Changeover arrangement if provided</p> Signup and view all the answers

    What should be recorded in the inspection register during equipment inspection?

    <p>Inventory and date of inspection</p> Signup and view all the answers

    When should the external alarms' proper functioning be checked?

    <p>Quarterly</p> Signup and view all the answers

    What should be reported to the NMS during battery charger inspections?

    <p>Current setting as per load</p> Signup and view all the answers

    How often is it required to check the air conditioning systems?

    <p>Quarterly</p> Signup and view all the answers

    Which of the following checks is included in the periodical checks for the battery set?

    <p>Checking of electrolyte level</p> Signup and view all the answers

    What is one piece of equipment that must be provided at a centralized location for testing?

    <p>Cable fault locator</p> Signup and view all the answers

    Which of the following is not included as a responsibility for the JE/SSE?

    <p>Carrying out administrative duties</p> Signup and view all the answers

    What type of tester should each maintenance gang have according to the requirements?

    <p>Digital multi meter</p> Signup and view all the answers

    What is a primary cause of alarm in performance parameters during equipment operation?

    <p>Loss of incoming signal at 64 Kbps input port</p> Signup and view all the answers

    Who supervises the critical yearly schedule/tests/adjustments?

    <p>ADSTE/DSTE</p> Signup and view all the answers

    What must be checked during annual inspections by ADSTE/DSTE/Sr.DSTE?

    <p>Record of tests and failures</p> Signup and view all the answers

    What is the minimum space required between two rows of double-sided racks?

    <p>2 meters</p> Signup and view all the answers

    Which of the following should be observed regarding earthing in the equipment installation?

    <p>Earthing must comply with local electrical codes</p> Signup and view all the answers

    Which equipment is necessary for measuring insulation resistance?

    <p>Insulation resistance measuring set</p> Signup and view all the answers

    What is the primary frequency capability of the PCM MUX tester required for maintenance gangs?

    <p>Up to 8 Mbps</p> Signup and view all the answers

    What measures should be taken to prevent electrostatic discharge in electronic circuits?

    <p>Wear a proper anti-static strap/wristband</p> Signup and view all the answers

    What must be maintained in the relevant pro forma by the JE/SSE in charge?

    <p>Records of tests and maintenance schedules</p> Signup and view all the answers

    What is the acceptable distance from major sources of electromagnetic radiation when installing networking equipment?

    <p>3 meters</p> Signup and view all the answers

    Which of the following conditions requires immediate action to rectify a fault?

    <p>Loss of frame alignment</p> Signup and view all the answers

    When installing a digital cross connect, what is the minimum spacing requirement above the rack for cable carriers?

    <p>30 CM</p> Signup and view all the answers

    What is the significance of maintaining an excessive error ratio alarm of 1 in 10E 3 in framing pattern?

    <p>It signifies acceptable performance parameters</p> Signup and view all the answers

    Which topology is NOT mentioned in the system's configuration options?

    <p>Star topology</p> Signup and view all the answers

    What is the required action after a fault is conveyed by NCC/Control Office?

    <p>Consult NCC/Control Office to ascertain the nature of the fault</p> Signup and view all the answers

    What should maintenance staff do with defective and working spare modules?

    <p>Maintain a history of all equipment failures</p> Signup and view all the answers

    What is the main goal of the SSE/JE during an OFC outage?

    <p>Restore the link</p> Signup and view all the answers

    Which of the following tributaries supports a bandwidth of 10/100/1000 Mbps?

    <p>Ethernet systems</p> Signup and view all the answers

    How often should joint testing of protection channels be conducted?

    <p>Once in three months</p> Signup and view all the answers

    Which action should be taken first during fault rectification?

    <p>Restore working fibers through both ends first</p> Signup and view all the answers

    What type of cable interface is specified for the system?

    <p>Optic fibre cable</p> Signup and view all the answers

    What is the unit represented by the abbreviation 'AH'?

    <p>Amp Hour</p> Signup and view all the answers

    Which unit is primarily used to measure the volume of a liquid?

    <p>Litre</p> Signup and view all the answers

    In the context of energy consumption, which unit corresponds to time measurement?

    <p>Hrs</p> Signup and view all the answers

    What annexure is associated with the maintenance format for the fibre optic system?

    <p>Annexure E</p> Signup and view all the answers

    What does the abbreviation 'Amp' stand for?

    <p>Ampere</p> Signup and view all the answers

    Study Notes

    Chapter XIV: Digital Multiplexing Equipment

    • Digital multiplexing equipment currently uses Synchronous Digital Hierarchy (SDH), specifically STM-1, STM-4, and STM-16.
    • Future systems will use IP-MPLS technology.
    • Transmission media includes symmetric cable pairs, HDSL, star quad cable in electrified areas, and optical fiber.
    • Primary multiplexing equipment multiplexes 30 analogue and/or data channels into a 2048 Kbps ITU-compatible digital stream.
    • This equipment also demultiplexes the 2048 Kbps stream into 30 analogue voice/data channels.
    • Terminal MUX has one 2048 Kbps port per direction (transmit and receive) and is used as an end multiplexer.
    • Primary Drop/Insert MUX has at least two 2048 Kbps ports (P1 and P2) for sending and receiving signals. It enables dropping or inserting channels or making time slots between P1/P2 ports.
    • Drop/Insert MUX with Conference Facility has an additional capability for three-party conferences between time slots on ports P1 or P2 and voice interface.
    • Primary multiplexers include various interface cards such as 2W speech cards, 4W speech cards, exchange end cards, and subscriber side interface cards. Other types include hotline interface cards, Digital Subscriber Line Interface cards, Network Termination Unit/Remote Data Unit, and various Data Interface cards (e.g., G703, NX64 Kbps).
    • Digital multiplexing equipment specifications conform to RDSO (Research Designs and Standards Organisation) specifications.

    Characteristics of Interfaces

    • Bit rate, Code, output and input port characteristics for various interfaces vary, including 2048 Kbit/s ±50 PPM and HDB3.
    • Output ports, for example, have rectangular pulse shapes, specific peak voltages/impedances and normal pulse widths.
    • Input ports have permissible attenuation, return loss, frequency, and specific error requirements.

    System Performance Requirements

    • System designs meet ITU-T parameters and aim for 99.5% system availability.
    • Audio frequency (4W/2W) interface characteristics are measured according to ITU-T G.712 requirements.

    Synchronization

    • Equipment derives timing signals from internal, external, and incoming digital signal tributaries.
    • Automatic switching between timing sources occurs in case of primary source failure.
    • Synchronization schemes are per approved standards.

    Frame Structure (2048 Kbps)

    • Frame structure conforms to ITU-T recommendations (G.704/G.732).
    • Frame consists of 32 time slots (0-31).
    • Time slot 0 is for frame synchronization and alarms.
    • Time slot 16 is for channel signaling (1 to 15 and 16 to 31).
    • Remaining slots are for speech or data.

    Fault Conditions & Actions

    • Maintenance of primary and STM1 equipment must coordinate with telecom staff.
    • Specific alarm indicators (e.g., Power supply failed, Loss of incoming signals, Loss of frame alignment, Excessive error ratio, Remote failure, Loss of transmit clock) are common.

    Maintenance

    • Each piece of equipment has detailed maintenance procedures.
    • Electrostatic discharge precautions should be followed.
    • Maintenance schedule covers several critical components and checks, such as alarm checks, voltage checks, audio level checks, idle channel noise, signalling, operations (E&M, exchange circuits), circuit total distortion, and similar.

    Digital Cross-Connect (14.3.7)

    • Digital Cross-Connect (DCC) is provided to facilitate channel-level cross-connects, using 4-port to 32-port configurations.
    • DCC is important for operational flexibility.

    Room Sizes and Spacing (14.3.8(i), (ii))

    • Equipment room layout must allow for sufficient movement space for doors and routine equipment checks.
    • Clearance between the ceiling, cable carrier, and rack should be at least 30 cm.
    • Clearance between equipment racks or other equipment and walls should be at least 2 meters.

    Other Important Information

    • Equipment operation is at 48 VDC positive earth and often uses a shared power supply arrangement.
    • Various annexures provide specific data lists (e.g., Power Supply, Air Conditioner, Fire Alarm, Earthing) for checking/maintenance.