What is the first step required to lower the oil level in the tap changer head?
What is the first step required to lower the oil level in the tap changer head?
Which precautions should be taken when handling the switching oil during maintenance?
Which precautions should be taken when handling the switching oil during maintenance?
What should be monitored through the inspection glass while draining oil from the tap changer head?
What should be monitored through the inspection glass while draining oil from the tap changer head?
Which action is necessary to uncouple the drive shaft at the upper gear unit?
Which action is necessary to uncouple the drive shaft at the upper gear unit?
Signup and view all the answers
Why is it important to avoid open fire during the oil handling process?
Why is it important to avoid open fire during the oil handling process?
Signup and view all the answers
What quantity of oil should ideally be drained from the tap changer head?
What quantity of oil should ideally be drained from the tap changer head?
Signup and view all the answers
What must be taken into consideration concerning the pumping equipment used during maintenance?
What must be taken into consideration concerning the pumping equipment used during maintenance?
Signup and view all the answers
Which component's operation should be initiated if an oil filter unit is present?
Which component's operation should be initiated if an oil filter unit is present?
Signup and view all the answers
What is the maximum allowable number of tap change operations for the diverter switch units of the tap changer before replacement is required?
What is the maximum allowable number of tap change operations for the diverter switch units of the tap changer before replacement is required?
Signup and view all the answers
For the M II 350 D on-load tap changer with a rated current of up to 350 A, how many tap change operations can it perform without requiring any MR oil filter?
For the M II 350 D on-load tap changer with a rated current of up to 350 A, how many tap change operations can it perform without requiring any MR oil filter?
Signup and view all the answers
If a transformer performs 15,000 tap change operations per year, when is the first mandatory inspection interval?
If a transformer performs 15,000 tap change operations per year, when is the first mandatory inspection interval?
Signup and view all the answers
What is the recommended inspection interval after the first inspection is carried out?
What is the recommended inspection interval after the first inspection is carried out?
Signup and view all the answers
What should be done when a tap changer reaches approximately 1,000,000 switching operations?
What should be done when a tap changer reaches approximately 1,000,000 switching operations?
Signup and view all the answers
Which of the following is a requirement for transformers operating under high switching operation conditions?
Which of the following is a requirement for transformers operating under high switching operation conditions?
Signup and view all the answers
What measurement method is referenced for testing oil quality in transformers?
What measurement method is referenced for testing oil quality in transformers?
Signup and view all the answers
How many tap change operations can the M III 600 D perform with an MR oil filter?
How many tap change operations can the M III 600 D perform with an MR oil filter?
Signup and view all the answers
What action should be taken before removing the upper supporting cylinder?
What action should be taken before removing the upper supporting cylinder?
Signup and view all the answers
Which components are used to secure the link for the tap change supervisory control system?
Which components are used to secure the link for the tap change supervisory control system?
Signup and view all the answers
What should be avoided to prevent damage to the diverter switch unit?
What should be avoided to prevent damage to the diverter switch unit?
Signup and view all the answers
What type of screws are used for the connection of the supporting cylinder?
What type of screws are used for the connection of the supporting cylinder?
Signup and view all the answers
What cleaning method is recommended for the supporting cylinder?
What cleaning method is recommended for the supporting cylinder?
Signup and view all the answers
What could lead to creeping paths that may damage the system?
What could lead to creeping paths that may damage the system?
Signup and view all the answers
Before starting the disassembly, what should be ensured regarding small parts?
Before starting the disassembly, what should be ensured regarding small parts?
Signup and view all the answers
What type of risks does dropping parts during disassembly pose?
What type of risks does dropping parts during disassembly pose?
Signup and view all the answers
What is the maximum torque specification for attaching the supporting cylinder with lock nuts?
What is the maximum torque specification for attaching the supporting cylinder with lock nuts?
Signup and view all the answers
Which components must be securely fastened with lock nuts when assembling the diverter switch unit?
Which components must be securely fastened with lock nuts when assembling the diverter switch unit?
Signup and view all the answers
What is the purpose of the diverter switch pole W in the assembly process?
What is the purpose of the diverter switch pole W in the assembly process?
Signup and view all the answers
How many screws are required to attach the lower supporting cylinder of pole W?
How many screws are required to attach the lower supporting cylinder of pole W?
Signup and view all the answers
What should be checked regarding the resistor leads of diverter switch pole W during assembly?
What should be checked regarding the resistor leads of diverter switch pole W during assembly?
Signup and view all the answers
Which part must be assembled first when setting up the diverter switch unit?
Which part must be assembled first when setting up the diverter switch unit?
Signup and view all the answers
Which operation should be performed to verify the mechanical function of the device?
Which operation should be performed to verify the mechanical function of the device?
Signup and view all the answers
What is the role of the 2 washers provided with each screw in the assembly process?
What is the role of the 2 washers provided with each screw in the assembly process?
Signup and view all the answers
What does the notation '50%' suggest in the context provided?
What does the notation '50%' suggest in the context provided?
Signup and view all the answers
When should the contacts be evaluated for replacement according to the value mentioned?
When should the contacts be evaluated for replacement according to the value mentioned?
Signup and view all the answers
What consequence may arise from not replacing the contacts when necessary?
What consequence may arise from not replacing the contacts when necessary?
Signup and view all the answers
What is indicated by the letter 'R' appearing multiple times in the context?
What is indicated by the letter 'R' appearing multiple times in the context?
Signup and view all the answers
What could the series of numbers '5555' signify in maintenance documentation?
What could the series of numbers '5555' signify in maintenance documentation?
Signup and view all the answers
What strategy should be implemented when the wear indicator reaches critical levels?
What strategy should be implemented when the wear indicator reaches critical levels?
Signup and view all the answers
Why is it critical for documentation to indicate the need for replacement?
Why is it critical for documentation to indicate the need for replacement?
Signup and view all the answers
What does the symbol 'x' followed by percent signs imply in the context?
What does the symbol 'x' followed by percent signs imply in the context?
Signup and view all the answers
Study Notes
Transformer Tap Change Operations
- Several transformers are detailed (M III 350 D, M III 500 D, M III 600 D), each rated for specific current capacities.
- Inspection intervals are based on experience with conventional oil qualities and the number of tap change operations.
- A tap selector in the tap changer is generally maintenance-free, but special cases may require Technical Service consultation after approximately 1,000,000 operations.
- Diverter switch units must be replaced after 800,000 operations.
Inspection and Maintenance Schedule
- Initial inspection required after 20,000 tap change operations, if yearly operations exceed 15,000.
- Further inspections occur every four years.
- Recommended use of stationary oil filter units for upkeep.
Handling Procedures
- Switching oil is flammable; handle with care, avoiding open flames and using appropriate pumping equipment.
- During maintenance, lower the oil level by closing the stop valve and opening the drain and bleeder valves.
- Approximately 10 litres must be drained until the diverter switch unit support plate is free of oil.
Diverter Switch Maintenance
- Uncoupling of the drive shaft involves loosening screws at the coupling bracket for clearance.
- Care must be taken to visually inspect and ensure cleanliness of surfaces to avoid damage from creeping paths.
- Proper assembly of the diverter switch is vital; ensure all parts are clean and accounted for to prevent operational blockages.
Important Assembly Steps
- Remove supporting components in reverse order, checking for mechanical functionality during reassembly.
- Max torque requirements are specified for attachment screws to prevent damage.
- Final checks for sufficient clearance in electrical components are crucial before testing the diverter switch unit's operation.
Safety Precautions
- Strict measures need to be followed to avoid dropping parts into the switch unit which could lead to malfunctions.
- Series of corrective actions and checks are outlined to confirm readiness before final installation of the diverter switch unit.