Electrical Engineering Drawings Quiz
78 Questions
0 Views

Electrical Engineering Drawings Quiz

Created by
@BestSellingBeige

Questions and Answers

What does the OILTAP®M installation drawing specifically refer to in this context?

  • An on-load tap-changer configuration
  • A switching mechanism design
  • A centric drive unit arrangement (correct)
  • An oil compartment design
  • Which document number corresponds to the oil compartment contact screening?

  • 7303360E (correct)
  • 893978BE
  • 8980133E
  • 8904778E
  • What aspect is NOT covered in the supplementary drawings for on-load tap-changers?

  • Maintenance requirements (correct)
  • Installation procedure
  • Mechanical properties
  • Electrical connections
  • How many contacts per plane does the tap selector contact arrangement accommodate according to the provided data?

    <p>10 to 22</p> Signup and view all the answers

    In the context of the OILTAP®M gearbox unit, what does the swivelling range determine?

    <p>The degree of rotation mobility</p> Signup and view all the answers

    Which characteristic is typically NOT emphasized in any OILTAP®M document?

    <p>Environmental impact</p> Signup and view all the answers

    What is implied about unauthorized use of the document?

    <p>It may result in legal consequences</p> Signup and view all the answers

    What type of drive unit is specifically referenced in the second sheet of the installation drawing?

    <p>Centric drive unit</p> Signup and view all the answers

    What may offenders be liable for according to the content?

    <p>Payment of damages</p> Signup and view all the answers

    What is prohibited without expressed authorization as mentioned in the content?

    <p>Utilization of the document</p> Signup and view all the answers

    Which of the following statements is true regarding the rights mentioned in the content?

    <p>All rights are reserved in the event of grants</p> Signup and view all the answers

    Which of the following actions can result in liability for offenders?

    <p>Unauthorized copying or distribution</p> Signup and view all the answers

    What type of document is referenced in relation to the OILTAP®M?

    <p>Operating Instructions</p> Signup and view all the answers

    What is implied about the nature of the content regarding patents and designs?

    <p>They have protected rights upon grant</p> Signup and view all the answers

    What consequence is stated for offenders who violate the usage of the document?

    <p>They will be held liable for the payment of damages.</p> Signup and view all the answers

    What is prohibited without expressed authorization?

    <p>The copying, distribution, and utilization of the document.</p> Signup and view all the answers

    What types of intellectual property rights are reserved in the document?

    <p>Patents, utility models, and ornamental design registrations.</p> Signup and view all the answers

    What is explicitly stated about the copying of the document?

    <p>It is prohibited without expressed authorization.</p> Signup and view all the answers

    What factor may impact the rights reserved concerning patents and designs?

    <p>The grant of a patent, utility model, or ornamental design registration.</p> Signup and view all the answers

    What is the potential legal consequence for individuals misusing the document?

    <p>They will be held liable for damages.</p> Signup and view all the answers

    What is the maximum operating position for a tap selector size C without a change-over selector?

    <p>10</p> Signup and view all the answers

    Which of the following is not a valid number of phases used for the OILTAP® M?

    <p>5 phases</p> Signup and view all the answers

    How many maximum operating positions can be achieved with a change-over selector of size 14?

    <p>27</p> Signup and view all the answers

    Which tap selector size is explicitly indicated as not applicable for multiple coarse tap selectors?

    <p>DE</p> Signup and view all the answers

    For the OILTAP® M with a phase configuration of three, which tap selector size requires a star point application?

    <p>Y</p> Signup and view all the answers

    What is the minimum number of phases for an OILTAP® M configuration?

    <p>1 phase</p> Signup and view all the answers

    In the OILTAP® M designation, what does the letter 'R' signify?

    <p>Resistor</p> Signup and view all the answers

    Which Um [kV] value is not listed for the OILTAP® M?

    <p>300</p> Signup and view all the answers

    What legal protections are implied with the grant of a patent, utility model, or ornamental design registration?

    <p>Protection against unauthorized copying</p> Signup and view all the answers

    What type of change-over selector is indicated with the letter 'W'?

    <p>Reversing change-over selector</p> Signup and view all the answers

    How many center positions can a configuration have if it has 3 center positions?

    <p>3</p> Signup and view all the answers

    What is explicitly prohibited regarding the document's content?

    <p>Communication of contents without authorization</p> Signup and view all the answers

    What is the consequence for offenders who violate the distribution rules of the document?

    <p>Payment of damages is required</p> Signup and view all the answers

    Which of the following is TRUE about the rights reserved in the context of patents?

    <p>They provide exclusive control over the invention</p> Signup and view all the answers

    In what year was the document copyright claimed by Maschinenfabrik Reinhausen GmbH?

    <p>2007</p> Signup and view all the answers

    What aspect is not mentioned regarding the tap selector?

    <p>Performance specifications</p> Signup and view all the answers

    What is the potential legal risk mentioned for individuals who copy or distribute the document?

    <p>Financial compensation claims</p> Signup and view all the answers

    Which type of document regulation is not indicated in the text?

    <p>Copyright of software</p> Signup and view all the answers

    The rated short-circuit duration for all configurations of on-load tap-changers is 6 seconds.

    <p>False</p> Signup and view all the answers

    The maximum rated step voltage for all models of on-load tap-changers is 3300 V.

    <p>True</p> Signup and view all the answers

    The maximum rated through-current for the M III 500 Y on-load tap-changer is 600 A.

    <p>False</p> Signup and view all the answers

    Offenders are not held liable for damages associated with the use of on-load tap-changers.

    <p>False</p> Signup and view all the answers

    The step capacity for the M I 601 model is rated at 1500 kVA.

    <p>False</p> Signup and view all the answers

    All configurations of the M III models operate with a three-phase (star point) application.

    <p>True</p> Signup and view all the answers

    Only the M I 1203 model can handle a rated short-circuit current of 60 kA.

    <p>False</p> Signup and view all the answers

    The tap selectors for the M I models do not apply to network applications.

    <p>True</p> Signup and view all the answers

    The OILTAP®M installation drawing includes only one sheet of information.

    <p>False</p> Signup and view all the answers

    The tap selector contact arrangement can accommodate up to 22 contacts per plane.

    <p>True</p> Signup and view all the answers

    The document prohibits copying without any restrictions.

    <p>False</p> Signup and view all the answers

    Liability for damages is exclusively limited to the copying of the document.

    <p>False</p> Signup and view all the answers

    All patents and designs are automatically registered in proprietary documents.

    <p>False</p> Signup and view all the answers

    The distribution of the document does not require any form of authorization.

    <p>False</p> Signup and view all the answers

    The oil compartment contact screening is referenced by the code 7303360D.

    <p>False</p> Signup and view all the answers

    Offenders of the document's distribution rules may face penalties for damages.

    <p>True</p> Signup and view all the answers

    On-load tap-changers are described in supplementary drawings with the code 8980125E.

    <p>True</p> Signup and view all the answers

    The rights reserved in the document include only copyrights and not patents.

    <p>False</p> Signup and view all the answers

    The mounting position of the tap selector terminals is described by the code 8904778F.

    <p>False</p> Signup and view all the answers

    Figure 3 provides an overview of the tap selector terminals according to a specified standard.

    <p>True</p> Signup and view all the answers

    All rights regarding patents and utility models are reserved without any exceptions.

    <p>True</p> Signup and view all the answers

    Unauthorized communication of the document's contents is permitted as long as no copies are made.

    <p>False</p> Signup and view all the answers

    The coverage of all types of intellectual property rights is irrelevant in the context of this document.

    <p>False</p> Signup and view all the answers

    The copyright claimed by Maschinenfabrik Reinhausen GmbH is from the year 2007.

    <p>True</p> Signup and view all the answers

    The OILTAP®M I 502 model is designed for use with transformers operating at a frequency of 16 1/3 Hz.

    <p>False</p> Signup and view all the answers

    On-load tap-changer M II 352 can only be used in conjunction with on-load tap-changer M I 351.

    <p>False</p> Signup and view all the answers

    The OILTAP®M II 502 features a single-pole configuration.

    <p>False</p> Signup and view all the answers

    Technical specifications for on-load tap-changers can be requested as they are not available in the document.

    <p>True</p> Signup and view all the answers

    The combination on-load tap-changer M III K is formed from two single-pole tap-changers and no two-pole types.

    <p>False</p> Signup and view all the answers

    The operating frequency of the on-load tap-changer models is irrelevant to the dimensioning of the transition resistors.

    <p>False</p> Signup and view all the answers

    The information about the tap windings must be based on a figure provided in the document.

    <p>True</p> Signup and view all the answers

    On-load tap-changers do not require any special diverter switch for operation.

    <p>False</p> Signup and view all the answers

    The maximum rated lightning withstand impulse voltage loads must be considered at position a1.

    <p>False</p> Signup and view all the answers

    For coarse tapping in the (+) position, the permitted withstand voltage 'a' must be disregarded.

    <p>False</p> Signup and view all the answers

    The fine tap changer winding and coarse tap changer winding are only connected at the start and end points.

    <p>True</p> Signup and view all the answers

    For loads involving impulse voltage, the voltage 'b' does not need to be considered between fine tap selector contacts.

    <p>False</p> Signup and view all the answers

    The position a0 refers to the center position of the change-over selector.

    <p>True</p> Signup and view all the answers

    Caution must be taken regarding the withstand voltage between the coarse tap changer winding and fine tap selector contact.

    <p>True</p> Signup and view all the answers

    The maximum lightning withstand voltage is defined only for the fine tap selector's end connection.

    <p>False</p> Signup and view all the answers

    The coarse tap selector does not affect the operation of the fine tap selector connected to a phase.

    <p>False</p> Signup and view all the answers

    Study Notes

    General Information on OILTAP® M

    • OILTAP® M identifies a specific transformer tap changer design.
    • The designation includes variations such as phase number and sector configurations.
    • Available configurations include 1 phase, 2 phases, or 3 phases.

    Type Designation Breakdown

    • Type example includes basic wiring diagram and configurations.
    • Current ratings (IUm) for different models, ranging from 350 A to 1500 A.
    • Various applications specified for different phase and connectivity conditions.

    Tap Selector Features

    • Maximum operational positions vary depending on the configuration:
      • Without change-over selector: up to 22
      • With change-over selector: up to 35
      • With multiple coarse tap selector: up to 107 positions.
    • Different tap selector sizes include B, C, and D variations.

    Tie-in and Potential Switches

    • Options for tie-in measures include resistors and switches, detailing specific configurations.
    • No tie-in resistor involves potential switches only, indicated as 'S.'
    • Potential switch combinations can include tie-in resistor or for configurations without tie-in.

    Installation Drawings and Supplementary Materials

    • Multiple installation drawings are provided for various units and configurations.
    • Specific drawing references include centric drive units and on-load tap-changer head versions, ensuring proper installation practices.

    OILTAP® M Characteristics

    • The OILTAP®M design maintains specific standards, ensuring compatibility and efficiency.
    • Owner's rights are strictly enforced against unauthorized distribution or utilization of documents related to OILTAP® M.

    Additional Technical Data

    • Key documents include supplementary details for on-load tap-changers and oil compartment contact screening.
    • Relevant drawings for excessively detailed mechanical systems, addressing both function and safety measures.
    • This document is protected regarding copying, distribution, and communication.
    • Offenders of copyright regulations can be liable for damages.

    General Overview

    • Document outlines technical specifications and drawings for OILTAP®M on-load tap-changers by Maschinenfabrik Reinhausen.
    • Distribution and use of the document's content without authorization are prohibited, with potential legal consequences for offenders.

    Technical Data Summary

    • On-load tap-changer models include M III 350 Y, M III 500 Y, M III 600 Y, and various M I models.
    • All models operate on three phases for M III series and single phase for M I series, identified as star or single applications.
    • Maximum rated through current (IUm) ranges from 350 A to 1500 A across different models.
    • Rated short-time current varies based on model, with values of 6 to 24 kA.
    • Rated short-circuit duration is consistently 3 seconds across models.
    • Rated short-circuit current varies from 15 kA to 60 kA depending on the specific model.
    • Maximum rated step voltage (Uim) is uniformly 3300 V across all models.
    • Step capacity (P StN) capacity ranges from 1000 kVA to 3500 kVA.

    Tap Selector and Wiring

    • Basic wiring diagrams are available for identifying tap selector terminals per MR standard.
    • Diagrams assist in understanding contact designations matched to dimensional drawings of the tap-changers.

    Special Types of On-Load Tap-Changers

    • Models M I 502 and M II 502 designed for traction supply transformers operating at 16 2/3 Hz.
    • Equipped with a specialized diverter switch for tailored operation within this specific frequency framework.
    • Two-pole on-load tap-changer models (M II 352/502/602) serve single-phase center-tap connections with technical specifications aligning closely with M III series.
    • Combination configuration allows for voltage regulation using a mix of single-pole and two-pole tap-changer models.

    Safety Considerations

    • Attention required for maximum lightning withstand impulse voltage, focusing on voltage loads concerning specific contact configurations.
    • Guidelines for coarse tap position recommend careful attention to withstand voltage between winding ends to ensure operational safety.

    Conclusion

    • Comprehensive technical parameters provide essential information for installation, safety, and operational guidelines concerning OILTAP®M tap-changers, ensuring performance and reliability in various applications.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on various electrical engineering drawings, including cylinder potential switches and installation drawings for on-load tap-changers. This quiz covers supplemental material that is essential for understanding electrical systems and their configurations.