Building Code Compliance Quiz
24 Questions
0 Views

Building Code Compliance Quiz

Created by
@FancyDalmatianJasper

Questions and Answers

What is the required minimum clearance for standpipe inlets?

  • 5 feet
  • 3 feet (correct)
  • 4 feet
  • 2 feet
  • How often should fire alarms be tested according to the requirements?

  • Every 6 months
  • Annually
  • Weekly
  • Every 30 days (correct)
  • What is the testing frequency for single-station smoke detectors?

  • Every year
  • Every 6 months (correct)
  • Monthly
  • Quarterly
  • Which of the following is NOT a requirement for exiting areas in a building?

    <p>Exits must have locks</p> Signup and view all the answers

    What type of device can large occupancy exit doors utilize to remain open?

    <p>Magnetic hold-open devices</p> Signup and view all the answers

    Which regulation requires that nothing block exits on the outside of the building?

    <p>57.10.08</p> Signup and view all the answers

    Which is a requirement regarding the maintenance of wet and dry standpipes?

    <p>Pipes must be in good condition</p> Signup and view all the answers

    What is the minimum door width required for exit doors?

    <p>36 inches</p> Signup and view all the answers

    What is the maximum allowable travel distance to reach a fire extinguisher in a facility?

    <p>75 feet</p> Signup and view all the answers

    Which of the following is true about fire doors?

    <p>They should maintain a 3-foot clearance around them.</p> Signup and view all the answers

    What is required for vent dampers, chutes, and elevator doors?

    <p>Vent dampers must be free from residue.</p> Signup and view all the answers

    What temperature should fire assemblies close automatically?

    <p>165 degrees or 50 degrees above ambient temperature</p> Signup and view all the answers

    Which item is NOT part of the inspection protocol for fire doors?

    <p>Ensure doors are painted bright colors.</p> Signup and view all the answers

    How often must fire extinguishers be maintained for facilities over 5,000 square feet?

    <p>Every year</p> Signup and view all the answers

    In the event of a fire, how should the elevator buttons be handled?

    <p>Hold the red button until the doors are completely closed.</p> Signup and view all the answers

    What is the rating requirement for a portable fire extinguisher in facilities?

    <p>At least a 5-B rating for every 5,000 square feet.</p> Signup and view all the answers

    What is the minimum thickness required for solid core doors used for openings?

    <p>1-3/4 inches</p> Signup and view all the answers

    Which of the following is NOT a requirement for doors opening into steps?

    <p>Doors should open inward only</p> Signup and view all the answers

    What must every room in a building have concerning egress?

    <p>At least two approved means of egress</p> Signup and view all the answers

    Which situation allows for semi-direct exiting in egress requirements?

    <p>Going through one adjacent bedroom with direct egress</p> Signup and view all the answers

    What is required when housing a child 12 years or younger on the second floor?

    <p>An adult supervisor must be on the second floor</p> Signup and view all the answers

    What is the rule regarding fuel-burning space heaters?

    <p>They must be vented to the outside atmosphere</p> Signup and view all the answers

    What is one regulation regarding fire exits in industrial occupancies?

    <p>Exits must be free from obstructions and hazards</p> Signup and view all the answers

    Which option correctly reflects a requirement about storage on roofs?

    <p>No storage is permitted on roofs that hinder Fire Department operations</p> Signup and view all the answers

    Study Notes

    General Safety Regulations

    • Maintain clear spaces around combustible storage areas such as motor, fuse box, panel, and sprinkler valves to prevent fire hazards.
    • Ensure fire escapes have operational drop ladders that are undamaged.

    Exterior Code Requirements

    • Maintain a 3-foot clearance around standpipe inlets, marked with an 8"x4" sign.
    • Inspect breakaway caps for integrity and ensure threads are in good condition.
    • Fire escape routes must be free of obstructions, including parked cars and trash.

    Interior Safety Standards (Lobby)

    • Keep lobbies clear of obstructions for unrestricted access.
    • Test fire alarms every 30 days and maintain records of inspections.
    • Single-station smoke detectors must be tested every six months with documentation retained.
    • Display the Fire Department's phone number prominently at the switchboard.

    Interior Exits Guidelines

    • Doors must open within 30 seconds without needing a key.
    • Hallways should be adequately lit for visibility.
    • Exit signs must be present and easily identifiable; if not visible, directional indicators are necessary.
    • Avoid placing furniture in hallways unless secured and out of the way; fire escapes must remain clear of storage.

    Occupancy Requirements for Public Spaces

    • Venues accommodating over 50 individuals must have two exits equipped with panic hardware; no deadlocks or regular door handles allowed.
    • Carpets and stairways must be free from tripping hazards.
    • Self-closing doors should not be propped open unless using approved magnetic hold-open devices linked with smoke detectors.

    Fire Protection Assemblies

    • Inspect fire doors for fusible link integrity; they should be intact without corrosion or paint.
    • Fire doors must remain unpropped and have a 3-foot clearance maintained around them.
    • Vent dampers, chutes, and elevators must be free from residues and ensure proper self-closing mechanisms.
    • Fire assemblies should close automatically at specified temperatures (165°F or 50°F above ambient).

    Fire Extinguisher Requirements

    • One 2-A portable fire extinguisher is required for every 5,000 square feet of floor area.
    • Ensure a portable fire extinguisher with at least a 5-B rating is accessible within 75 feet of any point in the facility.

    Housing Regulations for Non-Ambulatory Individuals

    • Non-ambulatory occupants must have solid core self-closing doors, opening onto safe landings without steps.
    • An alternate egress from the floor is mandatory; this can be through an exterior stairway.

    Miscellaneous Provisions

    • An adult supervisor must be present on the same floor as any child aged 12 or younger housed on the second floor.
    • All fuel-burning heaters must be vented outside to maintain air quality and safety.
    • Questions regarding occupancy limits should be directed to relevant health department authorities for clarification and compliance.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on building code requirements related to habitable structures, focusing on both interior and exterior standards. This quiz covers regulations for safety equipment, kitchen compliance, and signage for standpipes. Understanding these codes is crucial for ensuring the safety and functionality of residential buildings.