Full Transcript

Utility Emergencies, Second Edition Final Version, April 2014 DEFINITIONS Arc – The flow of an electric current across a gap between two conductors, terminals, or contacts. An arc can result in sparks, a loud noise, and a momentary or sustained outage as protect...

Utility Emergencies, Second Edition Final Version, April 2014 DEFINITIONS Arc – The flow of an electric current across a gap between two conductors, terminals, or contacts. An arc can result in sparks, a loud noise, and a momentary or sustained outage as protective equipment operates. An arc is capable of creating large amounts of heat and light. Breaker – Short for circuit breaker, a component that detects overload conditions and then disconnects and stops the flow of electrical current to protect and ensure safe operation of the system. BLEVE – Acronym for boiling liquid expanding vapor explosion. Circuit – A path through which electric current is intended to flow. A circuit originates from a central point and extends out to serve customers. Cross Arm – Located at the top of a utility pole, a wooden bar to which power lines are attached. The cross arm keeps the lines separated by a sufficient distance to prevent arcing. Distribution System – The electric distribution system links the transmission system to most customers. Distribution system includes primary and secondary lines. Fault – In an electrical power system, a fault is any abnormal electrical current. For example, a short circuit is a fault in which the current exceeds the normal load. An open circuit fault occurs when some type of failure interrupts a circuit. Fuse – A protective device, consisting of a conducting material, which melts and burns opening the circuit when a specified value is exceeded. When melted or blown, the flow of electricity is interrupted to prevent damage to equipment. The temporary disruption of a blown fuse that creates an outage until the fuse is replaced is far better than the type of extended outage that results when equipment is damaged and needs to be replaced. Fuses also limit the number of customers that are affected by the outage. Intrinsically Safe – Designed to be incapable of producing heat or spark sufficient to ignite an explosive atmosphere. Isolate – Actions taken to reroute power around a particular area, leaving it isolated from an energy source while repairs are made. K – Abbreviation for 1,000. (For example, 12 kV = 12,000 volts, 500 kV = 500,000 volts). Momentary Outage – An electrical outage lasting two minutes or less. Pothead – A device, which provides transition between underground cable to overhead lines or conductors. Primary – Electric service delivered between 2,000 and 50,000 volts to a distribution transformer, which, in turn, reduces voltage to secondary levels. 2 Utility Emergencies, Second Edition Final Version, April 2014 Recloser – An automatic protection device that senses and interrupts distribution system faults. Riser – The conductor part of transition leading from underground to overhead; may or may not include pothead. Secondary – Electric service taken at less than 2,000 volts. Most residential and business customers receive electricity from secondary distribution lines. Sectionalize – The process of opening switches or fuses to divide a circuit into sections to isolate the cause of the power outage. This reduces the impact of the power outage to the fewest possible customers by allowing power to move through undamaged parts of the system. Stopcock Valve – A quarter-turn valve used to restrict or isolate the flow of liquid or gas in a pipe. Substation – A location, which uses a collection of transformers to reduce voltage and circuit breakers to protect circuits. Sustained Outage – An electrical outage that lasts for more than two minutes. Switch – A device for making, breaking, or changing connections with in an electric circuit. Switching – The process of opening and closing switches to isolate an area from the flow of electricity. Time Weighted Average (TWA) – The average exposure to a contaminant or condition (such as noise) to which workers may be exposed without adverse effect over a period such as in an 8- hour day or 40-hour week. Transformer – A device, which transforms electric energy from one voltage level to another level. Transmission – The transmission system carries electric power at very high voltages, generally between 60,000 and 500,000 volts. It provides bulk transportation of electricity over long distances, usually from generating sources to substations for voltage reduction. Vapor Density – The ratio of the weight of a given volume of gas or vapor to the weight of an equal volume of air at the same temperature and pressure. A vapor density less than 1 indicates it is lighter than air and will rise; a vapor density greater than 1 indicates a vapor density heavier than air and will sink. V – Abbreviation for volt. Vault – A space underground for electric cables, transformers, and other parts of the underground electric system. Volt – The unit of measure of electric potential, which is the condition that causes electric energy to flow. 3 Utility Emergencies, Second Edition Final Version, April 2014 Additional Terminology Notes This manual will discuss the upper explosive limit (UEL) and lower explosive limit (LEL) of natural gas, propane, and carbon monoxide. Flammable limits are a range of concentrations over which, a flammable gas or vapor, mixed with air will burn if an ignition source is present. This range extends between the lower explosive limit (LEL) and the upper explosive limit (UEL).  Below the LEL, the mixture is too lean (or has too much oxygen and not enough fuel) and cannot burn.  Above the UEL, the mixture is too rich (or has too much fuel and not enough oxygen) and cannot burn. Generally, chemicals with a narrow flammable range are less hazardous or less flammable than those with a broad flammable range. Also, chemicals with a flammable range in the higher percentages are generally less hazardous or less flammable then those with a flammable range in the lower percentages. The term Time Weighted Average (TWA) is used in the carbon monoxide section. An explanation of the TWA is an average rate of exposure over the course of an eight-hour work shift. TWA levels are usually lower than ceiling values. Thus, a worker may be exposed to a level higher than the TWA for part of the day (but still lower than the ceiling value) as long as he is exposed to levels below the TWA for the rest of the day. 4 Utility Emergencies, Second Edition Final Version, April 2014 OVERVIEW Utility emergencies comprise a significant amount of our daily call volume. These emergencies can range anywhere from small-scale natural gas leaks, wires arching, electrical and/or gas odors to large-scale incidents that will require an expanded Incident Command System to be in place. Moreover, these incidents may require a single resource to mitigate or require multiple units and agencies to help ensure a successful outcome. It should be noted that this manual is in no way intended to guide you through a hazardous materials emergency. This manual is designed to assist the company officer with decision making and the appropriate actions to take at a utility emergency until additional resources arrive. A vital resource that should be requested early on is the assistance from the utility company. These individuals have special equipment and training that can provide the company officer with the expertise necessary to properly mitigate the hazard. If you have any doubt concerning your ability to manage an incident involving toxic gases or leaks request support from a hazardous material response team immediately. This manual covers common utilities that may be encountered by fire department personnel. Often times, company officers are tasked with the responsibility of securing utilities. On the incident scene, when you are given the order to take care of utilities or secure utilities, this normally refers to the electric and gas utilities. If the incident commander desires any other utility locked out or secured, they should the identify that utility in the order. Changes to this version include:  Recommendations mitigating interior vault fires.  Addition of a definitions section to explain terms used within the manual.  Addition of the interstitial space building construction feature.  Defined hazards associated with flexible gas lines.  Additional information on mitigation of downed power line incidents.  New schematics of gas and electrical delivery systems.  Additional information on residential circuit boxes.  Establishment of minimum response complements for gas leaks. 5 Utility Emergencies, Second Edition Final Version, April 2014 VIRGINIA UTILITY MARKING STANDARDS Damage to underground utilities can cause serious injury, death, and cause major economic consequences. In order to reduce these occurrences the Virginia State Corporation Commission approved the American Public Works Association’s (APWA) color codes to mark underground utilities. Color-coded surface marks (paint or a similar coating) should be used to indicate the locations and route of buried lines. To increase visibility, color-coded vertical markers (temporary stakes or flags) should supplement surface marks. All marks and markers should indicate the name, initials, or logo of the company that owns or operates the line and the width of the facility if it is greater than 50 mm (2 inches). If the surface over the buried line is to be removed supplemental offset markings may be used. Offset markings should be a uniform alignment and must clearly indicate that the actual facility is a specific distance away. The marker types that are most suitable to the terrain and site conditions shall be used. For example, flags and stakes in landscaped areas, snow, or loose soil. The marker may be as simple as a color-coded dash line. The color-coded line may also include the size line, owner of line, product, or the pipeline material. In areas of high traffic the line may be off set with direction arrows and distance markers. APWA Color Codes RED electric, cable, conduit, and lighting cable YELLOW gas, oil, steam, petroleum, or gaseous materials ORANGE communications, alarm, or signal lines, cable or conduit BLUE potable water PURPLE reclaimed water, irrigation and slurry lines GREEN sewer and drain lines PINK temporary survey markings WHITE proposed excavation The material type abbreviations are as follows:  CI- cast iron  CPR- copper  DI- ductile iron  PL- plastic 6 Utility Emergencies, Second Edition Final Version, April 2014  PVC-polyvinyl chloride  RFC- reinforced concrete  SCC- steel cylinder concrete  STL- steel  TC- terracotta  TR- transite  W/STL- wrapped steel The number for contacting Miss Utility is 1-800-552-7001. In Virginia, Miss Utility can also be accessed by dialing 811. 7 Utility Emergencies, Second Edition Final Version, April 2014 NATURAL GAS (METHANE) Methane is a simple hydrocarbon consisting of carbon and hydrogen. There are many of these compounds, and each has its own number of carbon and hydrogen atoms joined together to form a particular hydrocarbon gas or fuel gas. Vapor density in gases is defined as the weight of a given volume of gas compared to the weight of the same amount of air at the same temperature and pressure. Given the factor of one for air, any gas with a vapor density of less than one will rise and any gas with a vapor density of more than one will sink in air. Having a vapor density of.55, methane is a very light fuel gas. This means that any escaping natural gas will rise and, if released outdoors, will dissipate quickly from the site of a leak. There are no toxic components or health hazards associated with natural gas in wide-open outdoor areas. However, in heavy concentrations, it will displace the oxygen, causing drowsiness and suffocation from asphyxiation. Natural gas in its pure state is colorless and odorless. Mercaptan is a pungent odorant that is added as a safety precaution after it is received at the distribution site. The odorant is so powerful you can smell even the smallest quantity of gas in the event of a leak. The mercaptan is added at the distribution site. A note of caution is that natural gas in transmission pipelines and rail cars is not odorized, so leaks that do occur can go undetected creating a significant danger to first responders. The flammable range for natural gas is between 5% and 15 %. This means that any mixture in air of less than 5% or greater than 15% will not ignite. (Remember, when you have a reading below 5% or above 15% this is the reading only in the specific area you are metering at a reported gas leak and, at that specific area, it is too rich/too lean to ignite. However, somewhere on the outside perimeter of the area in which the leak occurred, you may have the proper ignition range.) The ignition temperature for natural gas is about 1200° F and can easily be ignited by something as simple as a doorbell or a cell phone. When operating on the scene of an inside gas leak in which your monitoring device is activating at LEL/UEL levels proper precautions should be taken to mitigate this hazard. The primary objective is to control the leak by turning off the gas to the specific appliance if possible or shutting off the gas to the entire structure. Once the fire department shuts off the gas to a residence or business it should be tagged appropriately. The fire department should then ensure that the utility company has been contacted so that the problem can be corrected before the gas is turned back on. In addition, ventilation should be performed to remove any gas odors or levels inside the structure. After these steps are taken the firefighters should repeat the monitoring process to ensure that no hazard exists before turning the scene over to the property owner. The expansion ratio of liquefied natural gas to a gas is 600:1.This can create a significant hazard when liquefied gas cylinders are exposed to heat from fire impingement creating a potential for a BLEVE to occur. Gas lines typically have operating pressures of 0.25 to 55 pounds per square inch (psi). The transmission lines range in size from 6” to 30” and have pressures up to 450 psi. These lines can generate 2,000 to 24,000 volts of static electricity. Figure 1 shows the path of natural gas from wells to users. 8 Utility Emergencies, Second Edition Final Version, April 2014 Figure 1: Transmission of natural gas to users. Natural Gas Emergencies The United States has the largest network of energy pipelines of any nation in the world. While many forms of transportation are used to move products such as natural gas, liquefied natural gas products, and liquid products through the U.S. to marketplaces, pipelines remain the safest, most efficient, and economical way to move these natural resources. One of the greatest single challenges to safe pipeline operations is the accidental damage caused by excavation, construction, farming activities, or even homeowner construction and maintenance. First and foremost, pipeline companies are responsible for the safety and reliability of their own pipeline systems. Additionally, federal and state regulators oversee compliance with a host of regulatory requirements. Despite all precautions, leaks may occur in pipeline systems. Any of the following events along the pipeline easement could indicate a pipeline leak:  A hissing or roaring sound. 9 Utility Emergencies, Second Edition Final Version, April 2014  Any unusual odor near the pipeline.  Dead or discolored vegetation in an otherwise green location.  Fire coming from the ground or appearing to burn above the ground, Figure 2.  Dirt being blown or appearing to be thrown into the air.  Water bubbling or being blown into the air at a pond, creek, or river.  A dry spot in a moist field. Figure 2: Natural gas fire. Firefighters should note the following information concerning marking systems for pipelines:  Markers show the pipeline’s approximate location; not its exact location.  Signs on the markers list the commodity transported, the name of the pipeline company and a telephone number where company representatives can always be reached.  Markers do not indicate how deep the pipeline is buried or how many lines are in the area.  Pipelines do not necessarily follow a straight line between two markers. Figure 3 shows some examples of pipeline markings. Figure 3: Pipeline markings. 10 Utility Emergencies, Second Edition Final Version, April 2014 To protect the pipeline from mechanical damage, road casings are installed at all major vehicular road and railroad crossings, Figure 4. These casings are separated from the pipe with insulators and the pipe ends are sealed. These seals are intended to keep water out and provide electrical insulation. The gooseneck vent pipes keep moisture from building in the air space between the casing and pipeline. Figure 4: Typical road crossing. Flexible Gas Line Flexible gas line has recently been used as alternative to the black iron pipe that was a mainstay in the construction industry for supplying of gas to a structure. The trade name for flexible gas line is corrugated stainless steel tubing or CSST /Trac Pipe or Ward Flex. The hose contains a yellow outer sheath with a thin stainless steel tube that carries the product, Figure 5.The flexible gas line weighs much less and installation time is often times much faster due to the decreased weight and material usage. Historically, the residential gas lines were found at the entry point of the structure to the kitchen and laundry areas when the initial construction was conducted. Due to increased usage of flexible gas lines, it is much more popular and common to run appliances in parts of structures that would not previously been used. For example, this hose can be run through walls to supply a fireplace in a remote living space such as a finished basement or bedroom. Problems that frequently occur are damage to the flexible gas line due to punctures in the line from other utilities or wall hangings. Additional problems exist when construction or home improvements are done and the flexible gas lines are installed improperly (such as installing a replacement hot water tank) resulting in leaks at the fittings. Gas leaks can be detected around light switches and electrical outlets from a damaged line in void spaces and gas seeking the path of least resistance. Figure 5: Gas main where flexible hose has been used. 11 Utility Emergencies, Second Edition Final Version, April 2014 Shut Off for Natural Gas Gas shut off valves are quarter-turn, Figure 6. The proper sequence for shutting off the utility in either a leak or fire situation is as follows: 1. At the appliance (if can be safely done). 2. At the meter. 3. At the curb box. Figure 6: Gas shut off valve. When shutting off the gas at the appliance, the shut off valve will be a quarter turn, just prior to the regulator and appliance that it is serving; Figure 7 shows red shut offs prior to an appliance. When shutting off the gas at the meter use a wrench or Halligan tool to turn the quarter-turn valve. Some residential homes have all of the shut off valves located in one location usually in a utility room. This is another method of isolating a gas leak to an appliance without shutting off gas to the entire home or business. Examples include, leaking boilers, water heaters, and appliances. Figure 7: Examples of quarter-turn valves in residential applications. When performing a shut off at a curb valve, use the five-sided wrench to remove the cover of the street valve, Figure 8. If the nut cannot be manipulated, use a striking tool to break the cast iron cover. Insert T-handle shut-off valve into box and seat it on the valve. The valve is identical to the valve located prior to the gas meter, and inline between the street and the structure. If the 12 Utility Emergencies, Second Edition Final Version, April 2014 valve cannot be located due to debris or dirt, the curb box should be removed by digging around the box with a shovel. The box rests on the valve and is not connected in any way. Once the box is removed, removing more dirt easily exposes the valve. The T-handle wrench will provide the leverage necessary to operate the valve. Figure 8: An example of a wrench removing a curb valve cover. Commercial gas meters are usually much larger and operate at higher pressures than residential meters. Figure 9. Turning off the wrong valve may create a more serious problem. Commercial occupancies may have several valves. The valve to shut off is the one located prior to the regulator. Figure 9: Commercial gas meter. Positioning For outside gas leaks and other outside gas emergencies, engine companies shall position the apparatus prior to and upwind of the hazard area whenever possible and identify an adequate water supply source. The general rule for apparatus positioning is no closer than 100 feet for the first arriving unit and a minimum distance of 300 feet for all other incoming fire apparatus. This will help ensure the safety of all emergency responders in case a gas leak is detected. If 13 Utility Emergencies, Second Edition Final Version, April 2014 personnel have an odor present when arriving on scene, the apparatus shall be moved immediately. Other responding equipment shall stage upwind and prior to the affected area and await an assignment from the initial engine company officer. The second engine should stage at a hydrant outside the hot zone and await the orders of the initial crews before taking any action. If later arriving apparatus is approaching the scene from a different direction of travel they should stage prior to the dispatched address to avoid traveling through the hazard zone. This will also allow for fire department personnel to shut down through traffic until the area is deemed safe. Crews should avoid parking their vehicles over sewers, valve covers, and manhole covers because the collection of gases in these locations could present a potential hazard to first responders. For inside gas leaks, units responding to the reported inside gas leak shall position in a manner to avoid parking next to any side of the affected address. Restated, units should not position directly in front of, to the rear of, or beside a building involved in a gas leak event. Outside Gas Leak An outside gas leak is defined as any flammable gas leak that has originated outside a structure and the gases have not migrated into the building of origin or exposures nearby. If the break is in a line that is reported to be over 2” in diameter, the incident should be upgraded to a hazardous materials response because of the increased risk of large amounts of escaping flammable gases. The initial alarm assignment for outside gas leaks not meeting the criteria for a hazardous materials response should consist of the following as a minimum:  1 engine company  1 truck or rescue This set of responding units allows for the engine company to identify a water supply, locate and secure the leak, and evacuate citizens, if needed. The specialty piece has the responsibility of providing ventilation, when necessary, metering, investigation of exposure, and assisting the initial crew with their assigned tasks. The officer of the first-arriving unit shall re-con the scene to determine the location and extent of the leak through an on-scene supervisor, contractor, or the person who reported the leak. Ultimately, the officer shall allocate other resources assigned to the incident appropriately and work with the gas company to mitigate the incident as safely as possible. Make sure the utility company has been called and is enroute to all active gas leaks. The first-arriving officer is responsible for determining the required resources necessary to mitigate the incident. He/she should call for any additional needs as soon as possible, and identify a staging area away from hot zone. Another serious hazard during a leak is the static electricity (up to 24,000 volts) that is building up in the leak area as the gas escapes. Do not touch or attempt to handle any plastic or steel pipe at the leak site. If it is necessary for personnel to come in contact with a leaking gas line, an approved grounding device shall be attached in an attempt to dissipate any static electricity that may be generated at or around the leak site. It is recommended that no fire department personnel crimp or clamp any leak unless it is an extreme life-saving situation. The spark of static electricity that may result could become a source of ignition. 14 Utility Emergencies, Second Edition Final Version, April 2014 In most cases if the leak is prior to a shut off:  No gas is entering any structure and is dissipating into the atmosphere.  The best course of action is no action.  Don’t cover any pipe that is leaking and do check for migration of gas in surrounding buildings, basements, and sewers.  Set up a hot zone, wait for the utility company to arrive, and let them mitigate the leak. The utility company requires their personnel to follow safety rules. Any utility company personnel in the hot zone shall wear their protective equipment that includes coveralls, hardhat, Nomex hood and eye protection. Additionally, fire department personnel shall ensure no persons enter a trench deeper than 5’ that is not shored (29 CFR 1926.651). To protect the utility company workers, units should position upwind with a 20 lb. dry chemical extinguisher and a charged hose line when necessary. When protecting the utility company you should position personnel close to the leak, but out of the immediate hazard area if the gas ignites. Also take into consideration that hose placement should not hamper the utility company from getting their equipment in place. In instances where the leak can be controlled by closing a curb valve or gas meter this maybe the best and quickest way to control the escaping gas. Do not operate any street valves, Figure 10. If the wrong valve is turned this may result in another emergency remote from the scene. If a gas valve has been turned off, do not turn it back on as this could, and probably will, cause an explosion. During an incident several years ago, a fire department member shut down a street valve and, realizing his mistake, he turned it back on. The street valve he shut off and on serviced several hundred homes and businesses in the area. This cost the gas company hundreds of thousands of dollars to repair. Figure 10: The image on the left shows a street valve and the image on the right shows a curb valve. Street valves should not be used. For instances where the leak cannot be controlled (i.e., high pressure gas lines, gas leaks underwater when a trench fills with water and gas is leaking, and/or leaking from a manhole cover, crack in street, drain), the officer should confirm the respective utility company is enroute, establish hot/cold zones for operations, and isolate the area. Personnel should consider the use of monitoring/detection equipment for area affected buildings; this may include evacuating buildings in affected area depending on the findings. Natural ventilation may be necessary to prevent the buildup of natural gas within a building area. 15 Utility Emergencies, Second Edition Final Version, April 2014 All non-essential personnel, including firefighters and civilians, shall be kept out of the hot zone. The DOT Emergency Response Guide (ERG) suggests an evacuation distance of 330 feet. This may include evacuating buildings located within or near the zone. Detection/monitoring equipment carried on the fire apparatus will be used to monitor these areas. Combustible gas meters must be intrinsically safe and bump tested prior to entering the hot zone. Do not depend only on the mercaptan odor to determine if there is a leak. In underground leaks where natural gas is passed through the soil, the mercaptan odor may be eliminated. The hot zone will be determined by the OIC using the results of the detection/monitoring equipment. Checking around sewer manholes and underground vaults is also suggested. In situations where you cannot find the leak, use a soapy water spray, to help pinpoint the source in piping and meters, Figure 11. Figure 11: Locating a leak with soapy water. All sources of ignition should be controlled. This includes open flames, electrical switches, gas fueled machinery, and engines. Only in extreme cases would fire department personnel perform clamping or crimping a leak. This should only be considered for lines that are ¾” or smaller. If you consider it necessary to stop the gas leak by clamping or crimping the line the following steps should be taken: 1. Several feet from the leak, dig a hole to expose the leaking line away from any gas readings. Gas lines are buried around 24” below the surface but it is not uncommon to find them only several inches to several feet deep. With plastic pipe, the gas company lays a yellow-coated wire over the gas line so their detectors can find the metal; the detectors cannot pick up the plastic pipe. Sometimes you may find a yellow banner tape above the line to give warning that the pipe is below. 2. Once this gas line is exposed, use a grounding spray or grounding device such as a wet towel over the pipe to ground and then safely clamp the line. Piping in the system may be steel or plastic with pressure maximums. Bare steel diameters range from ¾” to 8” with pressures up to 60 psi. Wrapped steel may be from ¾” to 20 inches in diameter with pressures up to 1,440 psi. The plastic polyethylene comes in yellow or tan ranges 16 Utility Emergencies, Second Edition Final Version, April 2014 in size from ½” to 8 inches in diameter with pressures up to 80 psi, the polyethylene pipe is susceptible to static electricity. The use of hand lines and/or dry chemical extinguishers should take into account the wind direction, humidity, weight of the gas, and any other factors pertaining to the migration of the vapor cloud. This information will assist the officer in deciding if a hoseline is to be deployed and what size the hose line should be as well as where to deploy the extinguisher for use. Outside Gas Fires The tactics and positioning employed for the outside gas leak can also be used for the outside gas fire, Figure 12. Apparatus and hoseline placement shall take the most strategic position with consideration to responding utility company vehicle needs. At a minimum, a 1¾” line along with a dry chemical extinguisher shall be deployed. Figure 12: Outside gas fire. It is very important to remember that if a gas line is on fire the best procedure is to protect exposures, Figure 13. A burning gas fire is not explosive, but if the fire is extinguished without shutting off the gas an explosive condition has been created. Figure 13: Exposure protection. 17 Utility Emergencies, Second Edition Final Version, April 2014 The fire can extend to other surrounding combustibles and hoselines should be operated to prevent the spreading of the fire while letting the gas fire continue to burn, Figure 14. Where possible, keep the area around the leak as dry as possible. This will allow the utility company to fix the leak rapidly and safely. When the utility company stops the flow of gas the fire will go out. Figure 14: Fire involving the gas meter. For burning gas meters, it will take a coordinated effort of two hoselines deployed on wide-fog patterns to extinguish the fire while providing protection for a firefighter to shut off the gas at the stop cock on the meter, Figure 15. When the gas meter is involved, and access to the meter shut off cannot be accessed, the best place to shut off the gas is at the curb valve. In older houses you may encounter road debris in the curb box pipe and access to the valve maybe unreachable. Figure 15: Coordinated attack of burning gas meter providing protection for shut off at stopcock. It will take a considerable amount of time for the area that was burning to cool down below ignition temperatures. Hose lines should be left in place for protection until the area is safe for crews to work. 18 Utility Emergencies, Second Edition Final Version, April 2014 Inside Gas Leaks The initial alarm assignment for inside gas should consist of the following as a minimum:  2 engine companies  1 truck or rescue  1 Battalion Chief If any occupants report feeling ill an EMS unit shall be added. The tasks that should be completed by the assigned units consist of:  Citizen evacuation, if deemed necessary,  Atmospheric monitoring,  Exposure protection and extinguishment (if necessary),  Hazard mitigation (if it can be accomplished safely), and  Ventilation. When an IDLH atmosphere is identified, an initial RIT shall be identified and consideration shall be given to increasing resources for a structure fire response. Caution and sound judgment should be used when conducting any gas leak investigation. The primary goal is to protect lives. The officer shall re-con the scene to determine the location and extent of the leak through an on-scene supervisor, contractor, or person that reported the leak. The officer shall determine the resource requirements for mitigation and call for any additional needs as soon as possible and stage resources away from immediate area. Radios, pagers, cell phones, flashlights and other equipment that is not intrinsically safe should not be used nor taken into potentially explosive atmospheres. All intrinsically safe equipment should be turned on prior to entering a gaseous atmosphere. A hot/cold zone for operations shall be established and all non-essential personnel and civilians shall be kept out of the hot zone. This may include evacuating an entire building or a group of buildings in the zone. Where concentrations are the highest, ventilation should be started immediately. Detection/monitoring equipment carried on the fire apparatus will be used to monitor these areas; this equipment shall be intrinsically safe and bump tested prior to entering the hot zone. The hot zone will be determined by detection and monitoring. Closed doors should be cracked slightly to insert the probe and a reading obtained before opening the door. Opening a door or venting an atmosphere that is above the Upper Explosive Limit (UEL) could cause an explosive atmosphere and subsequent explosion. In large homes, crews should also be cognizant of the possibility that more than one meter could be serving the single-family dwelling. All occupants shall be evacuated from the danger area. All ignition sources shall be eliminated by manual controls. No electric switches shall be operated in the hazard area. Where possible electric service shall be controlled and shut down from the exterior of the involved structure. Consideration must be given to a potential ignition source being an auxiliary generator. If the power to a structure is shut off at the electric panel this action may cause the generator to operate. Secure the generator prior to operating the electric panel. 19 Utility Emergencies, Second Edition Final Version, April 2014 Upper stories, attics and cocklofts need to be monitored due to the vapor density of natural gas (.55). All exposures shall be monitored to determine the extent of the leak. All sources of ignition shall be controlled if necessary. Natural ventilation should be the primary tactic used to remove the gases. When appropriate, the safest way to remove the hazard would be to shut off the gas at the meter. However, in large commercial buildings, shutting off the gas at the meter could seriously disrupt manufacturing procedures and may generate further hazards. Any valve that is turned off shall be red tagged, notification will made to the utility company, and an available building representative will be contacted. Gas-fired rooftop heating units are widely used in commercial and industrial facilities. Typically packaged with an air-conditioner and air-handling unit, single-package rooftop units can cover all the heating, ventilating, and air-conditioning (HVAC) needs of a facility. These self- contained units can be found on office buildings, grocery stores, schools, and a variety of other commercial and industrial facilities. Personnel encountering an odor covering an area inside a facility (with or without inside gas appliances) should assign a resource to check the rooftop for any odors from the HVAC unit(s) or rooftop service lines, Figure 16. Figure 16: Rooftop commercial HVAC units and exposed gas lines. On May 7, 2009, two captains, a lieutenant, and five firefighters were injured during a natural gas explosion at a strip mall in Maryland. At 1254 hours, dispatch reported a natural gas leak inside a business at a strip mall. Five minutes later, the initial responding crew and the incident commander (IC) arrived on scene to find a gas company employee looking for an underground gas leak. Approximately six minutes later, a natural gas leak was found near the exterior rear corner of the structure. After 23 minutes on scene, approximately 45 civilians were evacuated from 7 occupied businesses. A captain exited the rear door of the business that had reported the natural gas leak and noticed fire along the roofline. Crews in the front and rear of the structure had begun to pull hose lines as another captain was looking out the rear doorway of a middle unoccupied business and noticed the electric meter located on the exterior wall was on fire. Anticipating an explosion, he tried to leap out the rear doorway. At the same time, a firefighter had entered the front door of the 20 Utility Emergencies, Second Edition Final Version, April 2014 unoccupied business, noticed the heavy smell of natural gas, and felt air rush by as the structure exploded. Debris and fire blew out the front, rear, and roof of the structure. The captain who tried to leap out the rear doorway was blown into the rear parking lot and the firefighter who had entered the front of the structure was blown out the front door and covered with debris. Numerous other firefighters, primarily near the front of the structure, were blown off their feet and hit with debris. NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should ensure that:  Standard operating guidelines for natural gas leaks are understood and followed;  Utility companies (natural gas and electric) are contacted immediately to cut external supply/power to structures when gas leaks are suspected;  Gas monitoring equipment is adequately maintained and fire fighters are routinely trained on proper use;  Ventilation techniques are conducted after ignition sources are mitigated;  Rapid intervention teams are staged at the onset of an incident; and  Collapse/explosion control zones are established when dealing with a potential explosion hazard. The key to turning off gas service in any structure is locating the regulator. The regulator takes street pressure of up to 40 psi and steps it down to somewhere between ½ to ¼ psi prior to the meter. The piping after the regulator will be larger due to the reduced pressure. In older occupancies, gas lines found in occupied areas will be no more than ½ psi after the regulator. In some of the new occupancies, gas lines leaving the main regulator are 2 to 5 psi. This is because the gas may travel longer distances from the main regulator. Once at the appliance, an individual regulator will step it down again from 2-5 psi to somewhere between ½ to ¼ psi. Most commercial and all residential appliances use gas at a pressure of ½ to ¼ psi. Firefighters should be familiar with residential gas meters. There are two basic types of gas meters, inside and outside, Figure 17. Figure 17: Two basic types of gas meters: outside (image on left) and inside (image on right). Prior knowledge of the area is the best means of determining the presence and type of gas service. In the absence of prior knowledge, a thorough size-up focusing on meter type will need 21 Utility Emergencies, Second Edition Final Version, April 2014 to be undertaken. Examine all areas of the exterior walls near the ground to approximately five feet above ground. Landscaping may need to be pushed aside to accomplish this. Members are looking for a meter in outside installations or looking for the vent pipe from the regulator on inside installations. All inside or enclosed gas installations are required to have the regulator vented to the outside via piping. This is a safety feature to prevent gas from being discharged to the interior of the building in the event the regulator fails. The piping vent pipe will be within five feet of the vent on an inside wall. The vent pipe will likely have a cover screen to keep water, insects, and debris out of the gas relief piping, Figure 18. If the screen becomes blocked, it is designed to blow out in relief. Figure 18: Examples of gas vents; the presence of a gas vent on an exterior wall is an indication of an inside gas meter. When turning the gas off at the meter crews should operate the shut-off valve prior to the meter. The valve is a quarter-turn valve in the piping prior to the regulator. Normally this is the pipe emanating from the ground. Before closing the valve, note the sound of gas flowing through the meter and look for movement of the numbers on the face of the meter. After the valve has been closed, the sound and movement should stop. 22 Utility Emergencies, Second Edition Final Version, April 2014 Figure 19 shows a bank of residential meters that supply individual occupancies; however there is only one shut off that is located prior to the regulator. Figure 19: Bank of residential meters with one shut off. In the event that the shut-off on an inside residential installation cannot be operated due to fire or accessibility, the gas should be turned off at the curb box. All truck and rescue companies, and some engine companies, carry gas shut off keys that may be used to close this valve and control the gas. Firefighters shall not attempt to shut off gas service by operating valves in street boxes or manholes. Only utility company personnel should operate these valves. Operating valves located in street boxes and manholes may actually increase pressure to customer service; obviously, this would be devastating to appliances designed to operate at ½ to ¼ psi. The differences between a street box and curb box are that the curb box is located between the street itself and the building. A street box is located out in the street and should not be operated by fire department members. In single-family installations, a curb box is usually located in the front lawn between the sidewalk and street, or located in the driveway or sidewalk leading to the residence. In multiple- family installations, it can be found anywhere between the street or parking lot and the building. Begin a search for the curb box by looking for yellow painted lines on the street or utility company discs embedded in the asphalt. These may point to the location of the curb box. Use a tool to tap the soil in the lawn in the area of these markings. The curb box may be covered by grass and dirt. Gas service will usually enter the building where the vent pipe or meter is located. It is also possible to start at the vent pipe at the building and walk towards the street while closely examining the ground. Confirm the gas being turned off by noting extinguishment of blue flames or checking the inside meter for flow. Most piping located underground in a curb box is usually at a depth of 2’-3’, although it may be more. If the valve cannot be located due to debris or dirt, the curb box should be removed by digging around the box with a shovel. The box rests on the valve and is not connected in any way. Once the box is removed, removing more dirt easily exposes the valve. The T-handle wrench will provide the leverage necessary to operate the valve. 23 Utility Emergencies, Second Edition Final Version, April 2014 In cases where the fire department has been called to an inside gas leak with nothing found, the source of the odor might be a dry J, P, or S trap in a drain. When a drain has not been used recently the water in the trap may evaporate and expose the building to sewer gases. Inside Gas Fires Initial responders dispatched for a reported structure fire can be surprised when they arrive and discover a gas meter or a gas appliance has failed is feeding the structure fire. Normal firefighting operations should commence with the exception of extinguishing the gas fire. A handline can be used to wet down the surrounding combustibles while the gas is shut off at the interior meter, if feasible. Gas burning from a meter is far safer than unburned gas accumulating in a burning basement area quickly reaching an explosive range. Command must be notified of the situation and request for the gas to be shut down. Shutting off the gas at the appliance, curb box or the meter should control the gas fire. It is not uncommon for the fire department to have difficultly shutting off the gas and a request for the gas company should be called for early into the incident. When the gas meter is involved, and access to the meter shut off cannot be accessed, the best place to shut off the gas is at the curb, Figure 20. In older houses you may encounter road debris in the curb box pipe and access to the valve maybe unreachable. Figure 20: Curb box located in a yard. Explosion Incidents Where the Building is Not Supplied by Natural Gas Upon arrival of an incident for a building explosion you should always suspect and rule out a natural gas leak even if the building is not supplied with natural gas. The cause may be a broken gas main that runs under or near the incident and the gas may have leached into the building foundation. Gas may travel long distances underground before it escapes into the atmosphere. Earth probes should be used to determine if gas escaping and caused the problem. Checking around sewer manholes and underground vaults is also suggested. Many incidents can damage gas line utilities producing leaks. A building damaged by a natural disaster (such as a tornado, earthquake, collapse due to snow load) and will most likely have damaged gas lines and generate leaks. Incidents for vehicles into a building should be thoroughly checked for damaged gas lines. Water main breaks or severe flooding can undermine the earth around gas lines causing leaks. Even downed high voltage electric lines have burned and damaged underground gas lines. 24 Utility Emergencies, Second Edition Final Version, April 2014 PROPANE Propane is a fossil fuel that is found mixed with natural gas and petroleum deposits in rocks deep underground. Propane was formed millions of years ago from dead plants and animals. When the plants and animals died, they sank to the bottom of the seas where they would mix with sand and silt that would eventually become thousands of feet thick. Under heat and pressure the composite would change into petroleum and natural gas deposits. Propane has an expansion ratio of 270:1. The vapor density of propane is 1.56, making it heavier than air. Propane will seek low areas and accumulate until it dissipates or find an ignition source. Propane has a LEL of 2.3 and an UEL of 9.5, and one gallon of liquid weighs 4.23 pounds. Propane has an ignition temperature between 920° F and 1,120° F. Propane in its natural form is colorless and odorless and ethyl mercaptan is added to propane for leak detection. The department of transportation requires any combustible/flammable gas in a distribution line to be odorized or have a natural odorant. It states that a person with a normal sense of smell should be able to detect a concentration in air of 20% of the lower explosive limit. The mercaptan is added at a rate of one pound per 10,000 gallons of liquid propane. This equates to a one part per billion. Propane is in a liquid state when contained and stored. In the liquid state propane has a specific gravity of 0.504 compared to water which is 1.0 making the propane liquid lighter than water. When released to the atmosphere it will change from a liquid to a vapor; during a release, the cloud that is visible is not product but the condensed moisture in the air that is cooled by the leaking product. Propane Emergencies Engine companies shall position the apparatus prior to and upwind of the hazard area if at all possible and determine the most efficient water supply. The other responding units shall stage upwind and prior to the affected area and await an assignment from the engine company or Incident Commander. Outside Propane Leaks A safe perimeter shall be established using detection/monitoring equipment; these must be intrinsically safe and shall be bump tested prior to entering the hot zone. Evacuation decisions should be based on monitoring data, wind direction, terrain, and size of the leak. Checking around sewer manholes and underground vaults is also suggested. It is imperative to check surrounding basements of buildings in the area for accumulating gas. Propane gas may travel long distances underground before it escapes into the atmosphere. Earth probes should be used to determine if gas escaping and caused the problem. Propane, being 1½ times heavier than air, will seek low areas, and the use of hoselines may be required to direct and disperse the vapor cloud away from ignition sources. It is recommended that two 1¾” hoselines with the nozzles on a narrow fog pattern be deployed for vapor dispersion. It is also suggested that additional lines be deployed to assist the initial line. When 25 Utility Emergencies, Second Edition Final Version, April 2014 breaking up the vapor cloud avoid allowing the run off to collect at the leak site to keep the area free of mud. The most common propane incident will involve the 20 lb. cylinder, Figure 21. It is estimated that there are 50 million of these cylinders in circulation. Every propane container will have at least one relief valve. The relief valve is designed to operate and release pressure when the internal pressure exceeds 250 psig and 375 psig depending on the size of the tank. If the relief valve is operating properly, do not stop the vapor release. Companies should have a hand line and dry chemical extinguisher ready in the event of a vapor ignition. Keep in mind that a hand line can also be used to move and/or dissipate vapors. Figure 21: Grill fire. All propane tanks need a 20% air space to accommodate the changes in ambient temperatures. We typically find the overfilling problem with the small 20 lb. cylinders. When the cylinder is overfilled and then stored in temperatures above the temperature that the tank was filled the relief valve may operate to relieve internal tank pressure. An example is in the summer and the outside temperature is in the 80s where the tank is filled. The tank is transported in the trunk of a vehicle where the temperatures rise above the 100 degrees Fahrenheit. If the tank was overfilled, it will more than likely relieve the pressure through the relief valve. If a container is on its side and liquid product is escaping from the relief valve the pressure in the tank is not significantly decreased. The liquid will boil off and expand to approximately 270 cubic feet of vapor for every pound of liquid released. The best objective would be to turn the tank over or upright the tank until vapor is releasing. With the liquid expansion ratio of 270:1, it is far safer to have a vapor leak than a liquid leak. Outside Propane Tank Fire or Tank Exposed to Fire When the tank is venting and the product is burning the best course of action is to cool the tank at the vapor space. When the internal pressure drops, the relief valve will close and the fire will go out. A 20 to 100 lb tank can be effectively cooled with a 50 gpm stream. The initial attack line should be the 1¾” line along with an additional backup 1¾” line. Do not direct water at the source of leak or at safety devices; icing may occur and restrict the discharge from the relief valve causing an increase of the internal pressure. When the relief valve sets, the crew protected by the attack line can move in and close the tank valve. If you are fighting a propane fire and you hear a rising sound from venting safety devices 26 Utility Emergencies, Second Edition Final Version, April 2014 or see discoloration of the tank leave the area immediately. The operation of the tank valve is the same as a water faucet, left to turn on and right to turn off. When approaching the tank do not stand or walk in the path of the relief valve; it may open at any time to relieve the tanks internal pressure. The attack line should continue to cool the tank to prevent re-ignition. If this situation is at the scene of a structure fire the tanks may be safely removed from the fire area and normal firefighting operations can continue. A 100-gallon tank can weigh up to 1000 lbs; the best way to move is to turn the tank on its side and roll it away. Be sure that the valve is completely shut off and avoid walking near the neck of the tank when rolling. Care should be taken when rolling the tank down steep grades. Be aware that when a BLEVE occurs, sections of the tank can fly in any direction, Figure 22. Just avoiding the ends of the tank should not be considered a safe operating procedure. When approaching a propane tank, do not stand or walk in the path of the relief valve; it may open at any time to relieve the tanks internal pressure. Figure 22: BLEVE of a propane tank. Propane Leaking Inside a Structure In structures where propane is used to service the major household appliances these types of leaks can be handled like inside natural leaks with the major exception of the LPG being heavier than air and will seek lower areas of the structure, Figure 23. The best place to turn off the gas is at the tank from the outside of the structure. Figure 23: This apartment building exploded due to the storage of a propane tank on the third floor. 27 Utility Emergencies, Second Edition Final Version, April 2014 CARBON MONOXIDE Carbon monoxide (CO) is formed by the incomplete combustion of the fossil fuels – gas, oil, coal, and wood used in boilers, engines, oil burners, gas fires, water heaters, solid fuel appliances, and open fires. Dangerous amounts of CO can accumulate as a result of:  Poor installation.  Poor maintenance or failure or damage to an appliance in service.  Fuel is not burned properly.  Rooms are poorly ventilated and the CO is unable to escape. CO is flammable and has a wide explosive range. The LEL for carbon monoxide is 12.8% and the UEL is 74%. In terms of parts per million (ppm) carbon monoxide’s explosive range would equate to 128,000 on the LEL and 740,000 on the UEL. Because CO has no smell, taste, or color, it is important in today’s world of improved insulation and double glazing to have good ventilation and maintain all appliances regularly. Additionally, every structure should have a reliable detector alarms installed, giving both a visual and audible warning immediately when there is a buildup of CO. Carbon monoxide cannot be detected by the body and can only enter the body by the respiratory system. Once in the lungs and the blood stream it is absorbed into the blood and combines with the hemoglobin of the blood and excludes the needed oxygen we require for survival. There are several factors that determine the harmful effects of carbon monoxide poisoning which include the concentration of the gas in air, how long the person(s) were exposed to the gas, age, sex, and health of the victim. Symptoms of exposure include headache, nausea, fatigue, confusion and dizziness. Rapid transport to an appropriate treatment facility is of the utmost importance. The Environmental Protection Agency (EPA), in the National Ambient Air Quality Standards (NAAQS), sets 9 ppm over a 24-hour time weighted average (TWA) as their standard for acceptable levels of carbon monoxide in outdoor (ambient) air. The OSHA PEL for carbon monoxide is 35 ppm over an eight hour TWA and 50 ppm over one hour. Carbon Monoxide Emergencies The dispatch complement to carbon monoxide alarms will vary from jurisdiction to jurisdiction. However, because of the potential hazard that exists, the recommended initial alarm assignment for carbon monoxide emergencies is:  1 engine company  1 EMS unit Due to incomplete combustion, carbon monoxide causes 1,500 accidental deaths and more than 10,000 injuries each year. The Occupational Safety and Health Administration (OSHA) has established a maximum safe working level for carbon monoxide at 35parts per million (PPM) over an eight-hour period, in the general workplace. The U.S. Environmental Protection Agency 28 Utility Emergencies, Second Edition Final Version, April 2014 has established that residential levels are not to exceed 9 PPM over an eight-hour average. Commercial buildings have many sources of CO not found in residences such as parking garages, drive-through windows, auto repair bays, various processes, un-vented gas burners in large confined spaces, forklifts, etc. Recognizing this, NIOSH established 35 PPM as the acceptable level for commercial buildings. Carbon monoxide is an odorless, tasteless, colorless gas that is deadly. It is a by-product of a fuel burning process. Many appliances such as furnaces, kitchen stoves, hot water heaters, and automobiles produce carbon monoxide. When a faulty device or unusual conditions exist, carbon monoxide may be vented into areas where people are present The majority of carbon monoxide incidents occur in the winter months, and the most common source of residential CO-related poisoning is un-vented supplemental heaters. Other common sources of carbon monoxide include:  Malfunctioning cooking appliances.  Tobacco smoke.  Clogged chimney.  Auto exhaust.  Malfunctioning water heater.  Malfunctioning oil, wood, gas, or coal furnaces.  Malfunctioning gas clothes dryer.  Wood burning fireplace, decorative fireplace, gas log burner, or any unvented space heater.  Appliances in cabins or campers, barbecue grills, lack of adequate ventilation, pool/spa heaters, and ceiling-mounted heating units.  Generators.  Malfunctioning batteries.  Relining of sewer lines. Carbon monoxide poisoning may be difficult to diagnose. Its symptoms are similar to the flu, which may include headache, nausea, fatigue, and dizzy spells. Persons with existing health problems, such as heart and lung disease, are especially vulnerable, as are infants, children, pregnant women, and the elderly. CO detection/monitoring equipment must be intrinsically safe and bump tested prior to entering the hot zone. Firefighters called to the scene of any CO alarm or smell of natural gas should dismount from the apparatus with full turnout gear and air packs in place. If the detection/monitoring equipment shows a reading of 35 ppm or above, the occupancy shall be immediately evacuated and crews should retreat from the structure and don their SCBA face piece before making reentry. During the investigative stage, the occupancy should not be ventilated, ignition sources should be eliminated, and the source of the CO located. Sometimes it may take many hours for the CO level to rise to the alarm stage and if the occupancy is vented then the source may not be found. It is not uncommon to have CO levels up to 10 ppm in a structure. In instances when your investigation finds readings greater than 10 ppm, you should notify the occupants of the above 29 Utility Emergencies, Second Edition Final Version, April 2014 normal readings, advise them that they need to have their appliances checked by an approved service representative. Additionally, attempt to reset their CO alarm, have the occupants review the manual for their CO monitor and tell them to call 911 if the detector activates again. Any person who enters the structure above 35 ppm shall have full turnout gear, including SCBA donned. In instances when your investigation finds readings greater than 100 ppm, the occupancy may be in a potentially lethal range and the building should be evacuated. If the appliance that is malfunctioning can be determined, that appliance shall be shut down. Natural or mechanical ventilation should be conducted. The mechanical ventilation should use electric fans and not gas- powered fans. Inform the occupants of your actions, advise them to have the appliance checked and repaired by an approved service representative, and attempt to reset their CO detector. You should advise the occupant not to return to the occupancy until repairs have been completed. The following chart is an OSHA standard where an average adult worker in good health compiled the results. This chart does not take into account the victims age, sex, and health. Table 1: OSHA standards for CO exposure. PPM’s Effects Time Elapsed 35 No effect 8 hours 200 Minimal effect 15 minutes 200 Slight headache, Fatigue, Nausea 2-3 hours 400 Life-threatening Frontal Headache 3 hours 800 Dizzy, Nausea, Convulsions, Unconscious 45 minutes 800 Death 2-3 hours 12,800 Death 1-3 minutes 30

Use Quizgecko on...
Browser
Browser