🎧 New: AI-Generated Podcasts Turn your study notes into engaging audio conversations. Learn more

rPP PCD Phase Adaptive Dimming Power Pack PDF

Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...

Document Details

VictoriousParrot2255

Uploaded by VictoriousParrot2255

2023

Tags

phase dimming power pack lighting control dimmer electrical equipment

Summary

This document provides specifications and details about the rPP PCD phase adaptive dimming power pack. It covers features like dimming control, power monitoring, and emergency options. The product is for controlling various lighting loads.

Full Transcript

Catalog Number: Date: Project: OVERVIEW The rPP PCD power pack is an adaptive phase control dimmer that delivers significant performance and design versatility. It is designed to control large...

Catalog Number: Date: Project: OVERVIEW The rPP PCD power pack is an adaptive phase control dimmer that delivers significant performance and design versatility. It is designed to control large phase dimmed loads, controlling forward-phase- dimming and reverse-phase-dimming loads as large as 16A at 120VAC and 277VAC. Long range wireless communication and the rPP PCD's ability to control full circuits make this device ideal for controlling phase-dimmed loads in both new construction and renovation projects. FEATURES rPP PCD Provides phase dimming control for 2-wire dimming fluorescent, electronic low voltage, incandescent, and magnetic low voltage loads 1 Phase Adaptive Controls loads as small as 0A and as high as 16A at 120VAC and 277VAC Dimming Power Power monitoring is standard via current measurement with +/- 2% accuracy Intelligently selects appropriate dimming method Pack Optional built-in, UL 924 compliant emergency options for simpler installation Meets NEMA SSL 7A for flicker-free dimming performance 2 Includes a replaceable fuse, which protects the device from overload and short circuit faults Warranty Five-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. Specifications subject to change without notice. ORDERING INFORMATION rPP PCD EFP G2 Series Emergency Fault Protection Territory Compliance Generation rPP PCD Phase Adaptive Dimming [blank] None EFP External Fault Protection [blank] None G2 Generation 2 compatibility Power Pack ER UL 924 Emergency Operation, CP Chicago Plenum via power sense leads EM 3 UL 924 emergency operation, via separate normal power sensing device Notes: 1. See Output Ratings section for supported loads, load sizes, and dimming types. ACCESSORIES 2. Meets NEMA SSL 7A when operating in forward-phase mode with Low Trim Level set to 24V. 120VAC applications only. NPP FUSE J10 Replacement Fuse 3. EM devices require an nLight AIR device in the same group to be connected to normal power for wireless normal power detection. See the UL 924 Response section for more information. Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com rPP PCD © 2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/23 1 of 4 SPECIFICATIONS Electrical Input Ratings 120-277VAC, 50/60 Hz Relay Type Zero-cross, Latching Class Rating Class 1 Current Monitoring Minimum Current required to ensure +/- 2% Accuracy Mechanical Dimensions 4.82”H x 4.72”W x 3.53”D (122mm x 120mm x 90mm) - includes heat sink and 3/8” chase nipple Weight 24oz Mounting 1/2” Knockout (7/8" hole) Wires 12 AWG stranded Enclosure Color White (standard), Red (ER & EM) Environmental Warrantied Operating Temperature Standard: -20°C to 50°C (-4°F to 122°F) Standard: -20°C to 40°C (-4°F to 104°F) if installed within an enclosure Relative Humidity Up to 90%, Non-Condensing General Standards/ Ratings System Component to aid in compliance with Title 24, ASHRAE 90.1, IECC NEMA NEMA SSL 7A NEMA 410 cULus UL 916 (E167435) UL 924 (EM & ER) UL 2043 CSA CSA-22.2 No. 141-15 RoHS Compliant Security Application Data Encryption: AES-128 bit Mutual Entity Authentication Message Confidentiality Message Authentication and Replay Prevention Limited Anonymity Complies with California Civil Code Title 1.81.26, Security of Connected Devices, approved under Senate Bill No. 327 (2018) Radio Frequency Dual Radio: 900MHz & 2.4GHz RF Transmit Power 900MHz: up to 20dBm 2.4GHz: up to 10.4 dBm Wireless Standard 900MHz: IEEE 802.15.4-based 2.4GHz: Version 4.0+ of the Bluetooth specification Wireless Range 900MHz: Up to 1,000 ft. (~304m) in free space/ line of sight Minimum of 150 ft through typical construction 2.4GHz: Up to 60 ft. (~18m) in free space/ line of sight Regulatory Compliance FCC ID: 2ADCB-RMODIT3 IC: 6715C-RMODIT3 IFETEL: RCPNLNL20-2057 Programming Tool CLAIRITY™+ Mobile App Output Ratings Device Type RPP PCD, NO ENCLOSURE RPP PCD, NO ENCLOSURE RPP PCD IN ENCLOSURE RPP PCD IN ENCLOSURE Ambient Temperature -20°C to 40°C -20°C to 50°C -20°C to 40°C -20°C to 50°C Operating Voltage 120VAC - 277VAC 120VAC - 277VAC 120VAC - 277VAC 120VAC - 277VAC General Purpose 16A 14A 12A 10A Incandescent (Tungsten) 16A 14A 12A 10A Magentic Low Voltage (Inductive) 16A 14A 12A 10A Electronic Low Voltage (Non-Inductive) 16A 14A 12A 10A Note: Where enclosures are required, such as for Chicago Plenum, enclosure dimensions should not be smaller than 12"x12"x6", and only contain one rPP PCD per enclosure. Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com rPP PCD © 2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/23 2 of 4 WIRING (Do Not Wire Hot) rPP PCD EFP G2 Legend rPP PCD EFP CP G2 LOAD * BLK – Unswitched Hot 120-277 WHT – Neutral BLU – Switched Output rPP PCD EFP G2 GRN – Ground } Normal rPP PCD ER EFP G2 rPP PCD ER EFP CP G2 UL924 Sequence of Operation: Emergency Legend RED – Unswitched Emergency Hot 120-277 nLight AIR Devices with ER Option Normal ER devices use an unswitched normal Emergency Load } WHT/RED – Emergency Neutral } BLK – Unswitched Normal Hot 120-277 WHT – Norm. Neutral hot to detect the presence of normal power. BLU – Switched Output ER devices will remain at their high-end rPP PCD ER EFP G2 GRN – Ground trim and ignore wireless lighting control - Optional Test Switch (by others) commands when normal power is not 120 V - present on the unswitched normal hot. 277 V rPP PCD EM EFP G2 Emergency Legend rPP PCD EM EFP CP G2 BLK - Unswitched Emergency Hot 120-277 } Emergency Load WHT – Emergency Neutral BLU – Switched Output GRN – Ground rPP PCD EM EFP G2 120 V - 277 V UL 924 Response – nLight AIR Devices with EM Option The below information applies to all nLight AIR devices with an EM option. EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. Using the CLAIRITY™+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, rPP PCD, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing. Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com rPP PCD © 2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/23 3 of 4 DIMENSIONS APD AIR STANDARD APD AIR EM/ER 4.82 3.94 4.72 1.87 3.53 APD AIR Acuity Brands | One Lithonia Way Conyers, GA 30012 Phone: 800.535.2465 www.acuitycontrols.com rPP PCD © 2023 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/28/23 4 of 4

Use Quizgecko on...
Browser
Browser