Fundamentals of Instrumentation and Measuring Systems PDF

Summary

This document provides an introduction to instrumentation and measuring systems, specifically focusing on the types of sensors used in civil engineering. It covers sensors like strain gauges, pressure sensors, temperature and humidity sensors, and displacement sensors, along with details of measurement systems. Applications in civil engineering, such as concrete curing, structural monitoring, and geotechnical monitoring, are also mentioned.

Full Transcript

Lecture 30 Introduction Framework of Measuring System: Measurement System Architecture Types of Measuring Instrumentation Applications Need of Calibration Introduction Measurement systems are traditionally used to measure physical and electrical quantities, such as mass, tempe...

Lecture 30 Introduction Framework of Measuring System: Measurement System Architecture Types of Measuring Instrumentation Applications Need of Calibration Introduction Measurement systems are traditionally used to measure physical and electrical quantities, such as mass, temperature, pressure, capacitance and voltage. However, they can also be designed to locate things or events, such as the epicenter of an earthquake, employees in a building, partial discharges in a high voltage power cable, or a land mine. Often, a measurement system is called upon to discriminate and count objects, such as red blood cells, or fish of a certain size swimming past a checkpoint. A measurement system is often made a part of the control system. The old saying ‘if you can’t measure it, you can’t control it’ is certainly a valid axiom for both the control engineer as well as the instrumentation engineer. Sensors are vital tools in civil engineering, playing a crucial role in various aspects throughout a project's lifecycle. From initial site surveying to construction monitoring and long-term health assessment of structures, sensors provide data for informed decision making. Here's a list of sensors and measuring systems used in civil engineering: Types of Sensors: Strain and Displacement Sensors: These measure deformations and movements in structures. Examples include: Strain Gauges: Attached to a structure's surface, they measure strain (deformation) caused by stress. Linear Variable Differential Transformers (LVDTs): These measure linear displacement over a specific range. Tiltmeters: They measure the angle of inclination, useful for monitoring settlement or leaning in structures. Pressure Sensors: These measure pressure exerted on a surface or within a substance. They are crucial for: Monitoring soil pressure for foundation stability assessment. Measuring water or gas pressure in pipelines. Tracking pressure in dams and retaining walls. Temperature and Humidity Sensors: These monitor environmental conditions that can affect material properties and structural behavior. Level Sensors: These measure the fill level of tanks, reservoirs, or for monitoring settlement in foundations. Motion and Vibration Sensors: These detect and record vibrations or seismic activity that can impact structures. Measuring Systems Sensors often work together within a larger measuring system that collects, transmits, and analyzes the data. This system may include: Data Acquisition Systems (DAQ): These systems collect and record sensor data. Communication Networks: Wired or wireless networks transmit data from sensors to a central collection point. Software: Data analysis software interprets the sensor readings, providing insights into structural health, environmental conditions, or construction progress. Importance of Sensors and Measuring Systems: Enhanced Safety: By monitoring structural integrity and environmental conditions, sensors can help prevent failures and accidents. Improved Design and Construction: Sensor data can inform design decisions and optimize construction processes. Efficient Maintenance: Regular monitoring allows for early detection of potential problems, facilitating timely and cost-effective maintenance. Structural Health Monitoring (SHM): Sensor-based systems provide continuous monitoring of structures, allowing for assessment of their health and performance over time. Framework of Measuring System: Measurement System Architecture Figure 1 illustrates the block diagram of a typical measurement system. The quantity under measurement (QUM) is converted to a useful form, such as a voltage, current or physical displacement by an input transducer or sensor. (Note the distinction between a sensor and a transducer—both devices are sensors, however, transducers have the capability to convert an input signal to some analog quantity). An example of a transducer is a piezoelectric crystal. A mechanical displacement (or equivalently, a force or pressure) applied to the crystal produces an output voltage, while an input voltage to the crystal produces a mechanical displacement. Another example is a loudspeaker. A current through the voice coil causes cone displacement, the rate of mechanical displacement generates a proportional current output. The output of the sensor, here assumed to be a voltage, is amplified and filtered by a signal conditioning subsystem. The purposes of the signal conditioning subsystem are to amplify, to give a low or matched output impedance and to improve the signal-to-noise-ratio (SNR) of the analog signal proportional to the QUM. The conditioned analog signal, V1, can be distributed to various display and recording devices. V1 can be displayed on an analog or digital oscilloscope, or a strip-chart recorder. It can also be recorded on a magnetic tape recorder, or it can be low-pass filtered to prevent aliasing and then periodically converted to digital words by an analog to digital converter (ADC). The ADC output, DN, is generally made an input to a digital computer through an appropriate interface. Once in the computer environment, the sampled and digitized QUM can be further (digitally) filtered, processed and stored on a magnetic hard and/or floppy disk, or on an optical disk in digital form. Often, the sensing instrument contains an ADC and is connected to a computer by a special instrumentation bus such as the GPIB or IEEE-488 bus (Hewlett-Packard calls the GPIB the HPIB). The GPIB is organized so that many GPIB-compatible sensing instruments can be managed by one master (host) computer. Figure 1. A generalized measurement system. Note that there are three major sources of noise in the measurement system shown in Figure 1. 1. Noise sensed along with the QUM (environmental noise) 2. Noise associated with the electronic signal conditioning system (referred to its input) 3. Equivalent noise generated in the analog to digital conversion process (quantization noise) These noise sources generally limit the resolution and accuracy of the measurement system. Many sensors provide the rate limiting element in a measurement system. That is, the response speed of the sensor is much slower than any of the other elements in the system. As a result of sensor dynamics, when there is a step change in the QUM, a measurement system may require a minimum settling time before a stable measurement can be made. Therefore, a settling time may be required for the sensor to reach a steady state output. Figure 2. Block diagram of measurement system Impedance techniques have been used for numerous years in civil engineering to monitor corrosion in steel reinforced concrete (rebar corrosion). This has now been extended to the actual characterization of cement microstructure, much of the work to date has centered on the later stages of hydration (after setting and during the hardening process). The ratios of individual components, such as ordinary Portland Cement (OPC) and pulverized fuel ash (PFA) and their effect on these processes has also been studied in the early stages of hydration. Electrical characterization techniques in civil engineering are providing vital information about microstructure and performance, it is envisaged that there use will continue to grow. Previous research has centered on the use of the Solartron 1260 FRA for data collection. It was noted that there is a need to improve this technology specifically for four terminal measurement applications such as the measurement of cementitious systems. Four terminal measurements allow more accurate measurement of the impedance of the concrete mixture by rejecting impedance contributions from the electrodes. This led to the development of the 1294 which extends the analysis capabilities of the Solartron 1260. Types of Measuring Instrumentation 1. Strain Gauge A strain gauge is a device used to measure the deformation (strain) of an object. In civil engineering, strain gauges are essential instruments for monitoring the health of structures, such as bridges, buildings, dams, and tunnels. By measuring the strain on a structure, engineers can assess its integrity and performance under various loading conditions. There are different types of strain gauges, but the most commonly used in civil engineering are electrical resistance strain gauges. These gauges consist of a thin grid of metallic wire or foil bonded to a flexible backing material. When the object to which the gauge is attached is subjected to strain, the wire or foil is also deformed. This deformation causes a change in the electrical resistance of the gauge. The change in resistance is proportional to the amount of strain, and this relationship can be used to calculate the strain on the object. Strain gauges are typically bonded to the surface of the structure using a special adhesive. Once bonded, the gauges are connected to a data acquisition system that continuously monitors the electrical resistance of the gauges. The data from the gauges can be used to track the strain on the structure over time and to identify any potential problems. Strain gauges are a valuable tool for civil engineers because they can provide real-time data on the condition of a structure. This data can be used to: Assess the safety of a structure Monitor the performance of a structure under construction Investigate the cause of structural damage Design new structures that are more resistant to strain Here are some of the common applications of strain gauges in civil engineering: Bridge monitoring: Strain gauges are used to monitor the strain on bridges under traffic loads. This data can be used to assess the safety of the bridge and to identify any potential problems. Building monitoring: Strain gauges can be used to monitor the strain on buildings during construction and after they are completed. This data can be used to ensure that the building is performing as expected and to identify any potential problems. Dam monitoring: Strain gauges are used to monitor the strain on dams due to water pressure and other factors. This data can be used to assess the safety of the dam and to identify any potential problems. Tunnel monitoring: Strain gauges can be used to monitor the strain on tunnels during construction and after they are completed. This data can be used to ensure that the tunnel is stable and to identify any potential problems. Figure 3. Electric resistance strain gauge The schematic diagram of an electrical resistance strain gage is shown in Figure 3. An electrical resistance strain gage consists of a fine wire whose resistance changes when it is subjected to mechanical deformation. When the strain gage is bonded to a structure, it experiences the same motion (strain) as the structure and hence its resistance change gives the strain applied to the structure. The wire is sandwiched between two sheets of thin paper. The strain gage is bonded to the surface where the strain is to be measured. The most common gage material is a copper-nickel alloy known as Advance. When the surface undergoes a normal strain the strain gage also undergoes the same strain and the resulting change in its resistance. The change in resistance of the wire can be measured using a Wheatstone bridge circuit. A typical Wheatstone bridge, representing a circuit which is sensitive to small changes in the resistance is shown in Figure 4. Figure 4. Wheatstone bridge circuit 2. Force Transducer A force transducer, also commonly known as a load cell, is a device used in civil engineering to measure applied forces. These forces can be tension, compression, weight or pressure. The transducer itself converts this mechanical force into an electrical signal that can be read and interpreted by data loggers or computers. There are several different types of force transducers used in civil engineering, but the most common type is the strain gauge load cell. These transducers work by having a strain gauge bonded to a metal beam. When a force is applied to the beam, it causes it to deform slightly. This deformation is measured by the strain gauge, which converts it into an electrical signal. Force transducers are used in a variety of civil engineering applications, including: Structural monitoring: Force transducers can be used to monitor the loads on bridges, buildings, and other structures. This information can be used to assess the safety of the structure and to identify any potential problems. Geotechnical engineering: Force transducers can be used to measure the pressure of soil and rock. This information is important for the design of foundations, slopes, and other geotechnical structures. Construction monitoring: Force transducers can be used to monitor the loads on construction materials, such as concrete and steel. This information can be used to ensure that the materials are not being overloaded. 3. Displacement sensors Displacement sensors function by measuring the movement or change in position of an object. In the context of civil engineering, this translates to monitoring the movement of bridges, buildings, dams, and other structures over time. There's a wide variety of displacement sensors used in civil engineering, each with its own strengths and applications. Here are some of the most common types: Linear Variable Differential Transformers (LVDTs): These versatile sensors employ the principle of electromagnetism to measure linear displacement. They consist of a primary coil, a secondary coil, and a ferromagnetic core. Movement of the core relative to the coils changes the voltage output, which is then correlated to displacement. LVDTs are known for their high accuracy and are ideal for monitoring movements in bridges, tunnels, and buildings. String Potentiometers: These simple yet effective sensors use a flexible cable wound around a drum. As the cable is pulled or released, the resistance changes, indicating displacement. String potentiometers are commonly used for measuring cable tension in suspension bridges and monitoring movement in landslides. Extensometers: Extensometers are specialized displacement sensors designed to measure very small changes in length. They are often used to monitor cracks in concrete structures, measure settlement of foundations, and track joint movements in buildings. Different designs exist, including mechanical, electrical, and vibrating wire extensometers. Tiltmeters: As the name suggests, tiltmeters measure the angle of inclination of a structure. They are crucial for monitoring the stability of slopes, dams, and retaining walls. Various technologies are employed in tiltmeters, including liquid levels, pendulums, and MEMS (Microelectromechanical Systems). Laser Displacement Sensors: These non-contact sensors utilize a laser beam to measure distance. They offer high precision and are well-suited for monitoring long-range displacements in bridges and tall buildings. The data collected by displacement sensors is vital for civil engineers in several ways: Structural health monitoring: By tracking movements over time, engineers can identify potential problems such as cracks, settlement, or leaning. Early detection allows for timely intervention and prevents catastrophic failures. Construction control: Displacement sensors are used to monitor the movement of structures during construction to ensure they stay within specified tolerances. Safety assessment: The data from displacement sensors can be used to assess the safety of a structure after a seismic event or other extreme loading conditions. 4. Temperature Sensors Temperature sensors play a vital role in civil engineering by monitoring the temperature of various materials and structures. This monitoring is crucial for ensuring the safety and integrity of civil engineering projects. Here's a description of temperature sensors used in civil engineering: Resistance Temperature Detectors (RTDs): These sensors use the principle that the electrical resistance of a metal wire increases with increasing temperature. RTDs are known for their high accuracy and wide range of operating temperatures. They are often used to monitor the curing temperature of concrete, which is important for achieving optimal strength. Thermocouples: These sensors consist of two dissimilar metals joined at one end. When the junction is subjected to a temperature difference, a voltage is generated. Thermocouples are known for their fast response time and wide range of operating temperatures. They are often used to monitor the temperature of steel structures, such as bridges, during welding or extreme weather conditions. Thermistor: It is a type of resistor whose resistance varies depending on temperature. They are often used in the civil engineering industry for temperature monitoring. Thermistors are embedded in concrete to monitor its curing temperature. Thermistors can be used to monitor the temperature of building envelopes, which can help to identify problems such as air leaks or insulation deficiencies. Thermistors can also be used to monitor the temperature of soil, which can be important for a variety of applications, such as slope stability analysis and foundation design. Applications of Temperature Sensors in Civil Engineering Monitoring Concrete Curing: Temperature is a critical factor in the curing process of concrete. Concrete curing is the process of keeping the concrete moist and at a moderate temperature for a specific period after it has been poured. This allows the concrete to hydrate properly and achieve its full strength. Temperature sensors are embedded within the concrete to monitor its temperature during curing. This data is used to ensure that the curing process is taking place correctly and to identify any potential problems, such as cracking or spalling. Monitoring Bridge Health: Bridges are subjected to a variety of stresses, including traffic loads and thermal expansion and contraction. Temperature sensors can be used to monitor the temperature of bridge components, such as steel girders and concrete decks. This data can be used to assess the health of the bridge and to identify any potential problems, such as fatigue or excessive movement. Monitoring Geotechnical Conditions: Temperature can also be an important factor in geotechnical engineering. For example, temperature sensors can be used to monitor the ground temperature around buried pipelines or storage tanks. This data can be used to assess the risk of frost heave or thermal expansion. Building Performance Monitoring: Temperature sensors can also be used to monitor the thermal performance of buildings. This data can be used to identify areas where the building is losing or gaining heat too quickly, and to make improvements to the building's energy efficiency. 5. Distance Sensors Distance sensors are electronic devices that measure the distance between the sensor and an object. They play a vital role in various aspects of the civil engineering industry, from initial surveying to structural health monitoring. There are several types of distance sensors used in civil engineering, each with its advantages and applications: Triangulation-based Distance Sensors: This sensor employs the principle of triangulation, hence the name. Here's how it works: The sensor has a laser emitter, a receiver, and a fixed distance between them. The laser emits a beam that strikes the target surface and reflects back. The receiver captures the reflected laser spot. Based on the angle of the reflected light and the fixed distance between emitter and receiver, the sensor calculates the distance to the target by using trigonometry. These sensors can be mounted on drones or mobile platforms to create detailed 3D models of terrain or infrastructure. Ultrasonic Sensors: These sensors emit high-frequency sound waves and measure the time it takes for the waves to bounce back from an object. They are widely used for short-range measurements due to their affordability and simplicity. However, they can be less accurate in noisy environments. Applications of Distance Sensors in Civil Engineering: Surveying and Mapping: Distance sensors are essential tools for land surveyors, who use them to measure distances, angles, and elevations to create accurate maps of construction sites. Construction Monitoring: These sensors are used to monitor the movement of structures during construction and overtime. This can help to identify potential problems and ensure the safety of workers and the public. Machine Control: Distance sensors are used in construction machines, such as excavators and graders, to automate tasks and improve accuracy. For instance, they can be used to control the depth of an excavation or the slope of a road. Building Information Modeling (BIM): Distance sensors can be used to collect data for BIM models, which are digital representations of buildings. This data can be used to improve the design, construction, and operation of buildings. Structural Health Monitoring: Distance sensors can be used to monitor the health of bridges, tunnels, and other structures over time. This can help to identify potential problems early on and prevent catastrophic failures. 6. Humidity Sensor Humidity sensors are electronic devices used to measure the amount of water vapor in the air. There are several different types of humidity sensors available, each with its own advantages and disadvantages. The most common types used in civil engineering include: Capacitive humidity sensors: These sensors use a capacitor to measure the amount of water vapor in the air. They are accurate and stable, but they can be expensive. Resistive humidity sensors: These sensors use a material that changes resistance in response to changes in humidity. They are less expensive than capacitive sensors, but they are also less accurate and stable. Thermal conductivity humidity sensors: These sensors measure the difference in thermal conductivity between dry air and air that contains water vapor. They are accurate and can be used in harsh environments, but they can be slow to respond to changes in humidity. The humidity information is crucial for various applications, including: Monitoring curing concrete: Proper curing is essential for concrete to develop its full strength. High or low humidity can negatively affect this process, so humidity sensors are used to track conditions and ensure optimal curing. Preventing mold growth: Mold thrives in humid environments. In buildings, high humidity can lead to mold growth on walls, ceilings, and other surfaces, which can cause respiratory problems and damage to the structure. Humidity sensors can help to identify areas where mold growth is a risk so that steps can be taken to control humidity levels. Ensuring occupant comfort: Humidity levels that are too high or too low can make buildings uncomfortable for occupants. Humidity sensors can be used to monitor indoor humidity levels and make sure they are within a comfortable range. 7. pH Sensor A pH sensor is a device that measures the acidity or alkalinity of a liquid. It is a crucial tool in the civil engineering industry for a variety of reasons. The most common type of pH sensor used is the glass electrode. It consists of a thin glass bulb filled with a solution of known pH. The bulb is immersed in the test solution, and the difference in potential between the internal solution and the test solution is measured. This potential difference is proportional to the pH of the test solution. Ion-Selective Field-Effect Transistors (ISFETs): An ISFET (Ion-Sensitive Field-Effect Transistor) is a type of transistor that uses an ion-sensitive membrane as its gate electrode. This allows it to directly measure the concentration of ions in a solution, like hydrogen ions (H+) for pH measurement. Changes in H+ concentration cause changes in the electrical current through the transistor, which can be measured and converted to a pH value. ISFETs could be embedded in steel-reinforced concrete to monitor for signs of corrosion by tracking changes in the pore solution's pH. Applications: Water Quality Monitoring: Civil engineers are often involved in projects that involve water quality monitoring, such as wastewater treatment and stormwater management. The pH of water is an important indicator of its quality. pH sensors are used to monitor the pH of water to ensure that it meets regulatory requirements. Corrosion Prevention: Corrosion is a major problem in civil engineering infrastructure. The pH of the environment can have a significant impact on the rate of corrosion. pH sensors are used to monitor the pH of the environment around structures to identify areas where corrosion is a risk. Need of Calibration Sensor calibration is crucial for ensuring the accuracy and reliability of data. Here's why calibration is essential: Improved decision-making: Accurate data from calibrated sensors empowers engineers to make informed choices regarding design, construction, and maintenance. Cost savings: Early detection of problems through calibrated sensors prevents costly repairs or even catastrophic failures. Enhanced project quality: Reliable data from calibrated sensors contributes to structures that meet performance expectations and last longer. Accuracy Assurance: Uncalibrated sensors can drift over time, leading to inaccurate readings. Calibration corrects these errors, guaranteeing the data reflects true real-world measurements. This is critical for tasks like monitoring strain on bridges or measuring concrete strength. Compliance with Standards: Many civil engineering projects have strict regulatory requirements. Calibration ensures sensors meet industry standards and building codes. This protects against potential legal ramifications and ensures project safety. Optimal Performance: Calibrated sensors function at their peak capability. This translates to more sensitive detection of changes, allowing for earlier intervention and improved overall performance of structures and monitoring systems. Data Integrity and Interpretation: Accurate sensor data is the foundation for sound engineering decisions. Calibration safeguards the integrity of this data, enabling engineers to make reliable interpretations and avoid basing critical choices on faulty information. Risk Mitigation: Uncalibrated sensors can lead to missed problems or misinterpretations of data. Calibration minimizes these risks, preventing potential failures and costly repairs down the line. Quality Control and Assurance: Calibration is a cornerstone of quality control and assurance in civil engineering. It ensures consistent and reliable measurements throughout a project, upholding high construction standards. Lecture 31 Strain Gauge Working mechanism of strain gauge Applications of Strain Gauge Force Transducer Technical specifications of Force Transducer Working mechanism of force transducer Applications of Load Cells Strain gauges: technical specifications Strain gauges come in various configurations, but they all share some common technical specifications: Resistance: This is the electrical resistance of the unstrained gauge. Typical values are 120 Ω, 350 Ω, 600 Ω, and 1000 Ω. Gauge Factor (GF): This is a dimensionless number that represents the change in resistance of the gauge relative to the applied strain. A higher gauge factor indicates a greater change in resistance for a given strain, making it easier to measure small strains. Strain gauges typically have a gauge factor of 2 or higher. Temperature Range: This is the range of temperatures over which the gauge can operate accurately. Strain gauges are often made from materials with a low coefficient of thermal expansion (CTE) to minimize errors caused by temperature fluctuations. Temperature Coefficient represents the change in resistance with temperature. It's essential to consider the temperature sensitivity of the strain gauge, especially in applications where temperature variations are significant. Strain Limit: This is the maximum strain that the gauge can withstand without permanent damage. Exceeding the strain limit can cause the gauge to break or become nonlinear. Active Grid Length (L): This is the length of the sensing element of the strain gauge. The strain is measured over this length. Overall Length (Lo): This is the total length of the strain gauge, including the tabs used for bonding the gauge to the test specimen. Grid Configuration: The grid pattern of the strain gauge affects its sensitivity and performance. Common configurations include linear, rectangular, and rosette patterns. Material: Strain gauges are typically made from metal foils (such as constantan or nickel- chromium) or semiconductor materials (such as silicon). The choice of material depends on the desired properties of the gauge, such as gauge factor, temperature range, and strain limit. Working mechanism of strain gauge A strain gauge is a sensor whose measured electrical resistance varies with changes in strain. Strain is the deformation or displacement of material that results from an applied stress. Figure 5. Strain Gauge The strain gauge must be connected to an electrical circuit that is capable of accurately responding to the minute changes in resistance associated with strain. Multiple strain gauges can be used in a divided bridge circuit to measure small changes in electrical resistance. This is called a Wheatstone bridge. In a Wheatstone bridge configuration, an excitation voltage is applied across the circuit, and the output voltage is measured across two points in the middle of the bridge. When there is no load acting on the load cell, the Wheatstone bridge is balanced and there is zero output voltage. Any small change in the material under the strain gauge results in a change in the resistance of the strain gauge as it deforms with the material. This causes the bridge to be thrown out of balance, resulting in a change in the output voltage. As stated earlier, the resistance change is minute, which means that signal amplification is often needed to properly determine changes. The amplification process strengthens the strain signal changes; however, it also leads to more unwanted noise also being detected in the signal. Signal conditioning filters out the excess noise, ensuring accurate and understandable data. When the structure experiences strain (deformation due to force), the gauge deforms along with it. If the structure is stretched, the filament becomes thinner and longer, increasing its resistance. Conversely, if the structure is compressed, the filament shortens and thickens, decreasing the resistance. Figure 6. Circuit diagram and positioning of strain gauge Applications of Strain Gauge Here are some key applications of strain gauges in this field: Structural Health Monitoring: Perhaps the most crucial application is monitoring the health of existing structures. Strain gauges are attached to critical points on bridges, buildings, dams, and other structures. The collected data helps engineers identify any early signs of weakness, cracks, or excessive stress before they become major problems. This allows for timely maintenance and repairs, preventing potential failures and ensuring public safety. Evaluating Design Effectiveness: Strain gauges play a vital role in evaluating the effectiveness of a design. During construction or after the initial load, engineers can install gauges to measure the actual strain experienced by different structural components. This data can be compared to the theoretical calculations made during the design phase. If any discrepancies arise, it allows for adjustments or improvements to be made, ensuring the structure performs as intended under real- world conditions. Monitoring Behavior Under Load: Strain gauges provide valuable insights into the behavior of a structure under various load conditions. This can be particularly important for bridges subjected to heavy traffic, wind loads, or seismic activity. By monitoring strain changes under different loading scenarios, engineers can assess the structure's capacity and identify potential points of vulnerability. This information can be used to establish weight limits, implement traffic restrictions during extreme weather events, or even inform future design modifications. Identifying Weaknesses and Stress Points: Strain gauges can be used to identify weaknesses or areas of excessive stress within a structure. By strategically placing gauges at critical locations, engineers can pinpoint areas experiencing higher than expected strain. This can be due to design flaws, material defects, or unforeseen environmental factors. Early detection of such issues allows for targeted interventions and helps prevent catastrophic failures. Beyond these primary applications, strain gauges can also be used for: Residual stress testing to measure the internal stresses present in a structure after construction. Rockfall testing to assess the load-bearing capacity of protective nets used along roadways. Calibrating load cells used in weighing systems for bridges or other structures. Strain gauges are a versatile and powerful tool that plays a vital role in ensuring the safety, durability, and performance of civil engineering structures. Their ability to provide real-time data on the behavior of structures under various conditions allows engineers to make informed decisions for construction, maintenance, and future design improvements. Force transducer: Technical specifications Force transducers used in civil engineering, often referred to as load cells, come in various configurations with a range of technical specifications depending on the specific application. Here's a breakdown of some key aspects to consider: Capacity: This refers to the maximum force the transducer can measure accurately. It's typically expressed in units like Newtons (N), KiloNewtons (kN), or MegaNewtons (MN). Civil engineering applications often require high capacity transducers ranging from hundreds of kN for monitoring structures to millions of kN for testing large-scale components. Accuracy: This specifies the degree to which the measured force deviates from the actual force applied. Accuracy is usually expressed as a percentage of the full-scale capacity. High-precision transducers used in critical applications can have accuracy within ±0.01% of their capacity. Output Signal: The transducer converts the measured force into an electrical signal for further processing. Common output signals include: o Millivolt per volt (mV/V): This is the most common output for strain gauge-based transducers. The output voltage changes proportionally with the applied force. o Current Loop (mA): This is a two-wire interface offering better noise immunity compared to mV/V outputs. o Digital (USB): Provides a digital representation of the force for direct connection to data acquisition systems. Nonlinearity and Hysteresis: These terms quantify deviations from the ideal linear relationship between force and output signal. They are usually expressed as a percentage of the full-scale capacity. Sensitivity: Sensitivity indicates the change in output signal per unit change in applied force. It is usually specified in millivolts per volt (mV/V) or microstrain per volt (με/V). Temperature Range: The operating temperature range specifies the conditions within which the transducer maintains its accuracy. Material: Load cells are typically made of materials such as stainless steel, aluminum, or alloy steel, chosen based on factors like durability, corrosion resistance, and environmental conditions. Mounting Type: Load cells come in various mounting configurations, including compression, tension, and shear, to suit different installation requirements Calibration: Regular calibration ensures the transducer maintains its accuracy over time. Some models offer built-in calibration features. Environmental Considerations: Civil engineering applications often involve harsh environments. Transducers may need to be: Waterproof and submersible for underwater applications. Weatherproof for outdoor use, withstanding rain, dust, and extreme temperatures. Resistant to corrosion, especially for use in marine environments or with de-icing salts. Working mechanism of force transducer A force transducer, also known as a load cell or force sensor, is a device that converts a mechanical force into an electrical signal. This signal can then be measured and used to determine the amount of force being applied. When we use load cells, one end is usually secured to a frame or base, while the other end is free to attach the weight or weight-bearing element. When force is applied to the body of the load cell, it flexes slightly under the strain. When this action happens to a load sensor, the deformation is very subtle and not visible to the naked eye. To measure the deformation, strain gages are tightly bonded to the body of the load cell at pre- determined points, causing them to deform in unison with the body. The resulting movement alters the electrical resistance of the strain gages in proportion to the amount of deformation caused by the applied load. Using signal conditioning electronics, the electrical resistance of the strain gages can be measured with the resulting signal being output as a weight or force reading. A typical load cell consists of two parts: the main body and an attached electrical circuit. The main body is what bears the weight or force and accounts for most of the load cell’s size. Typically, it is made from high-grade steel or aluminium, which ensures mechanical reliability, and predictable and uniform strain distribution. The electrical circuit is housed within the load cell, tightly bonded to the main body. The circuit includes strain-gauges which are specialised parts of the circuit designed to sense the deformations of the main body. These strain-gauges consist of thin, electrically conductive wire or foil arranged in a tight zig-zag pattern. This pattern makes them sensitive to stretch and compression along their length, but insensitive across their width. As such, they can be precisely positioned to sense forces that run along particular axes. For example, shear beam load cells have their strain gauges positioned at a 45-degree angle to the loading axis, so as to maximise the detection of the shear strain running through the load cell. Applications of Load Cells Load cells are used in structural testing and monitoring of buildings, bridges, and other civil engineering structures. They measure loads, stresses, and deformations to assess structural integrity and performance. Load cells are employed in material testing laboratories to measure the strength, stiffness, and other mechanical properties of construction materials such as concrete, steel, and wood. Load cells are used in weighing systems for construction materials, equipment, and vehicles. They enable accurate measurement of loads during material handling, transportation, and storage. Load cells are installed in various construction equipment and machinery to monitor forces, loads, and torque. They ensure safe and efficient operation by preventing overloading and detecting abnormal conditions. Lecture 32 Displacement sensors Types of Displacement Sensors Technical specifications Applications Distance sensors Types of Distance Sensors Technical specifications Applications Displacement sensors They precisely measure the movement or change in position of an object. They come in various forms, each with its own operating principle, technical specifications, and ideal applications. Types of Displacement Sensors: Contact Sensors: These directly touch the object being measured. Examples include: o Potentiometers: A sliding contact moves along a resistive element, changing the output voltage based on position. These sensors utilize a resistive element and a wiper mechanism. As the position of the object changes, the wiper moves along the resistive element, causing a change in resistance. This change in resistance is measured to determine the displacement. o Linear Variable Differential Transformers (LVDTs): A core moves within a transformer, altering the output voltage proportionally to its displacement. Non-Contact Sensors: These measure displacement without physically touching the object. Examples include: o Inductive Sensors: These sensors use the principle of electromagnetic induction and consist of a coil and a movable metal target. As the target moves relative to the coil, it induces a change in the coil's inductance, which is detected and measured. o Capacitive Sensors: These sensors work based on changes in capacitance between two electrodes. As the distance between the electrodes changes due to displacement, the capacitance also changes. This change in capacitance is measured to determine the displacement. o Optical Sensors: Employ various light-based techniques like triangulation or time-of- flight to measure distance. (e.g., Laser displacement sensors) o Ultrasonic Sensors: Emit and receive sound waves to determine the distance to the target based on the time taken for the echo to return. Working mechanism The working principle varies depending on the sensor type. Here are some general examples: Potentiometer: As the knob (or other moving part) slides, it changes the resistance between the contact and the ends of the resistive element. This resistance change translates to a voltage change that reflects the displacement. Laser Displacement Sensor (Triangulation): A laser beam is emitted and reflects off the target object. The position of the reflected light spot on a position-sensitive detector determines the object's distance based on trigonometric principles. Inductive Sensors or Eddy Current Sensor: An energized coil generates an eddy current in a nearby conductive object. The strength of the eddy current changes as the object moves closer or further away, allowing for distance measurement. Linear Variable Differential Transformer (LVDT): A core moves within a transformer due to displacement, changing the voltage output proportionally. Technical specifications Displacement sensors are characterized by various technical specifications, including: Range: The range of displacement that can be measured by the sensor. Resolution: The smallest change in displacement that the sensor can detect. Accuracy: The degree of closeness between the measured value and the true value of displacement. Linearity: How well the sensor's output follows a straight line when the displacement changes. Response Time: The time taken by the sensor to respond to a change in displacement. Environmental Protection: Resistance to factors such as moisture, dust, and temperature variations. Output Type: Analog voltage, current, digital, or frequency output. Mounting Type: Whether the sensor is suitable for direct mounting or requires additional fixtures or adapters. Applications Structural Health Monitoring: Monitoring bridges, buildings, and dams for movement due to settlement, wind, or seismic activity (using LVDTs, inclinometers). Crack Detection: Tracking the growth of cracks in concrete or welds (using strain gauges). Vibration Monitoring: Measuring vibrations in structures caused by traffic or machinery (using accelerometers). Pile Integrity Testing: Evaluating the integrity of foundation piles (using sonic echo or impulse methods). Control Systems: Providing feedback for control systems in actuators or hydraulic machinery (using various sensor types). Distance sensors Distance sensors are electronic devices that measure the distance between themselves and an object. They achieve this using various technologies and have a wide range of applications in civil engineering. Types of Distance Sensors: Ultrasonic Sensors: These work like bats, emitting high-frequency sound waves inaudible to humans. The sensor measures the time it takes for the sound to bounce back from the object, calculating the distance based on the sound's speed. Laser Distance Sensors: These use a laser beam to measure distance. The sensor calculates the time it takes for the light to travel to the object and reflect back, offering high accuracy for long distances. Infrared (IR) Sensors: These emit infrared light and measure the phase shift or intensity change of the reflected light to determine distance. They are good for short-range applications and detecting presence. LiDAR (Light Detection and Ranging): This advanced technology uses pulsed laser light to create a 3D map of the surroundings. LiDAR offers high-precision distance and object location data. Working mechanism (General Principle) Most distance sensors follow a similar principle: Signal Emission: The sensor emits a signal (sound wave, light pulse, etc.) towards the target object. Signal Reflection: The signal bounces back from the object. Signal Detection: The sensor receives the reflected signal. Distance Calculation: Based on the signal type and the time it took for the round trip (emission- reflection-detection), the sensor calculates the distance to the object. Technical specifications Range: Maximum distance the sensor can measure effectively. Accuracy: How precise the distance measurement is. Beam Angle: Area covered by the emitted signal (wider for short-range, narrower for long- range). Resolution: The smallest increment of distance that the sensor can detect. Response Time: The time taken by the sensor to provide a distance measurement after receiving a trigger or activation signal. Field of View (FOV): The angular range over which the sensor can detect objects or surfaces. Output Type: Analog voltage, current, digital, or frequency output. Environmental Protection: Resistance to factors such as moisture, dust, and temperature variations. Power Supply: The voltage and current requirements for operating the sensor. Applications Land Surveying and Mapping: Distance sensors like LiDAR are used to create accurate topographical maps for land development and construction planning. Building Information Modeling (BIM): Laser scanners with distance sensors capture detailed 3D models of buildings for design, construction, and maintenance purposes. Machine Control: Sensors mounted on construction equipment like excavators and graders use distance data for precise positioning and automated operations. Structural Monitoring: Sensors can be used to monitor the movement and deformation of bridges, buildings, and other structures over time. Inventory Management: Short-range sensors can track inventory levels in warehouses and manage material deliveries. Safety Systems: Laser scanners can detect people or objects in hazardous areas, preventing accidents during construction activities. Lecture 33 Introduction to Temperature sensors Types of Temperature Sensors Working Principle Technical Specifications of Temperature Sensors Applications Humidity sensors Types of Humidity Sensors Applications of Humidity Sensors Working of Capacitive Relative Humidity Sensors Working of Thermal Conductivity Humidity Sensors Technical Specifications of Humidity Sensors pH Sensors: Overview and Working Principle pH Sensor Components Working of a pH Sensor pH Sensors Specifications Applications of pH Sensors Introduction to Temperature Sensors Definition: Temperature sensors are devices that measure temperature by converting thermal energy into electrical signals. Functionality: These sensors detect temperature changes and produce an electrical output that corresponds to the temperature. Types of Temperature Sensors Thermocouples o Principle: Based on the Seebeck effect, where a voltage is generated at the junction of two different metals that are exposed to different temperatures. o Advantages: Wide temperature range, fast response time, rugged and durable. o Applications: Industrial processes, power plants, and kilns. Resistance Temperature Detectors (RTDs) o Principle: Utilizes the change in electrical resistance of a material (typically platinum) with temperature. o Advantages: High accuracy, stable, good repeatability. o Applications: Laboratory measurements, industrial processes requiring precise temperature control. Thermistors o Principle: Made from ceramic materials that exhibit a large change in resistance with temperature. o Advantages: Highly sensitive, quick response time, inexpensive. o Applications: Medical devices, household appliances, automotive sensors. Infrared Sensors o Principle: Measures temperature by detecting the infrared radiation emitted by an object. o Advantages: Non-contact measurement can measure moving objects, suitable for high temperatures. o Applications: Remote temperature monitoring, thermal imaging, industrial equipment. Semiconductor Sensors o Principle: Uses the temperature-dependent properties of semiconductor materials to measure temperature. o Advantages: Small size, low cost, easy integration with electronic circuits. o Applications: Consumer electronics, environmental monitoring, automotive industry. Working Principles Thermocouples o Principle: Based on the Seebeck effect, where a voltage is generated at the junction of two different metals that are exposed to different temperatures. o Operation: When the junction of the two metals experiences a temperature difference, a voltage is produced that can be measured and correlated to the temperature. Resistance Temperature Detectors (RTDs) o Principle: Utilizes the change in electrical resistance of a material (typically platinum) with temperature. o Operation: As temperature increases, the resistance of the platinum increases linearly. This change in resistance is measured and converted into a temperature reading. Thermistors o Principle: Made from ceramic materials that exhibit a large change in resistance with temperature. o Operation: There are two types of thermistors: Negative Temperature Coefficient (NTC), where resistance decreases with an increase in temperature, and Positive Temperature Coefficient (PTC), where resistance increases with an increase in temperature. Infrared Sensors o Principle: Measures temperature by detecting the infrared radiation emitted by an object. o Operation: The sensor detects infrared radiation and converts it into an electrical signal, which is then processed to determine the temperature of the object. Semiconductor Sensors o Principle: Uses the temperature-dependent properties of semiconductor materials to measure temperature. o Operation: The voltage across the terminals of a diode changes with temperature. As the temperature increases, the voltage across the diode increases. This is followed by a drop in the voltage between the terminals of the transistor of the base and emitter in a diode. Vibrating Wire Temperature Meters o Principle: Based on the principle of stress change caused by temperature changes. o Operation: Uses dissimilar metals with different linear coefficients of expansion. As temperature changes, the stress on the wire changes, causing it to vibrate at different frequencies. These frequencies are measured and converted to temperature readings. Technical Specifications of RTDs Temperature Range: -50°C to 500°C Accuracy: ±0.5°C Response Time:

Use Quizgecko on...
Browser
Browser