BAL_1800115_03_001_EN.PDF
Document Details
Uploaded by BestSellingBeige
null
Tags
Related
- On-load tap-changer OILTAP® M Technical Data TD 050/03 PDF
- Technical Data TD 61 General Section PDF
- On-load tap-changer OILTAP® V V Technical Data PDF
- On-load tap-changer OILTAP® V Technical Data PDF
- Technical Data On-Load Tap Changer Type H PDF
- VACUTAP® VM®, VM 300, VMS® On-load tap-changer Technical Data PDF
Full Transcript
www.reinhausen.com On-load tap-changer OILTAP® R Technical Data TD 115/03 2 TD 115/02 115/02/01/0 Table of Contents Table of Contents 1 General........................................................................................
www.reinhausen.com On-load tap-changer OILTAP® R Technical Data TD 115/03 2 TD 115/02 115/02/01/0 Table of Contents Table of Contents 1 General.................................................................................................................................................................................................................. 4 1.1 Summary of the technical data....................................................................................................................................................... 4 1.2 Survey....................................................................................................................................................................................................... 6 2 Technical Data................................................................................................................................................................................................... 15 2.1 Rated through-current (Iu), rated step voltage (Ui) and step capacity (PStN)................................................................ 15 2.2 Contact life............................................................................................................................................................................................. 17 2.3 Rated withstand voltages of the internal insulation................................................................................................................ 17 3 Appendix – dimensional and installation drawings.......................................................................................................................... 20 NOTE These technical data are intended for the calculator and designer of the transformer. These type-specific data are only valid in connection with the information contained in the general section (TD 61) since this section contains important information on such subjects as potential connection, leakage inductance, current division, and so on. Dimensional drawings and connection diagrams are subject to change without prior notice. Drawings submitted during bidding and ordering are always binding. Since the on-load tap-changer is delivered to the specifications of the transformer manufacturer, the transformer manufacturer is responsible for selecting the correct properties of the on-load tap-changer so that the requirements of the transformer are met. 115/02/01/0 TD 115/03 3 1 General 1 General 1.1 Summary of the technical data On-load tap-changer R III 1200 Y R I 1201 R I 2002 R I 24023) R I 3003 Number of poles and application 3 (neutral point) 1 1 1 1 Max. rated through- 1200 1200 2000 2400 3000 current Ium (in A) Rated short-time withstand 15 15 24 24 30 current (in kA) Rated short-circuit duration 3 3 3 3 3 (in s) Rated peak withstand current 37.5 37.5 60 60 75 (in kA) Max. rated step voltage Uim 4000 4000 4000 4000 3000 (in V)1) Step capacity (PStN) 3000 30002) 44002) 60003) 6000 (in kVA) Rated frequency (in Hz) 50 to 60 Operating positions Without change-over selector: max. of 18 With change-over selector: max. of 35 Rated insulation level Highest voltage for 72.5 123 170 2459) 300 3627) equipment Um (in kV)5) Highest operating voltage Ub 55 79 145 170 245 3008) (phase-phase) on diverter switch (in kV) Rated lightning impulse with- 350 550 750 950 1050 1175 stand voltage (in kV, 1.2 I 50) Rated switching impulse 850 950 withstand voltage (in kV) AC withstand voltage 140 230 325 395 460 510 (in kV, 50 Hz, 1 min.) Rated withstand voltages of see table 3 internal insulation Oil compartment Pressure-proof up to 0.3 bar continuous difference pressure (test pressure 0.6 bar), head and cover of the on-load tap-changer are vacuum-proof. Oil suction pipe Installed as standard (for details, see BA 18) Temperature range The on-load tap-changer OILTAP® R can be operated in the rated load range with oil temperatures of -25 °C to +105 °C. Table 1 a 4 TD 115/03 115/02/01/0 1 General On-load tap-changer R III 1200 Y R I 1201 R I 2002 R I 2402 R I 3003 Weight without change- 525 360 4454) 445 525 (in kg) ca. over selector with change- 595 (7704)) 410 (5004)) 505 (6404)) 505 (6404)) 595 (7804)) over selector Displacement 72.5 kV 289 (3674)) 274 (3534)) 280 (3604)) 280 (3604)) 286 (3674)) volume 123 kV 314 (3924)) 299 (3764)) 305 (3844)) 305 (3844)) 311 (3924)) (in dm3) ca. 170 kV 334 (4124)) 319 (3964)) 325 (4044)) 325 (4044)) 331 (4124)) 245 kV 354 (4324)) 339 (4164)) 345 (4244)) 345 (4244)) 351 (4324)) 300 kV 369 (4464)) 374 (4534)) 374 (4534)) 380 (4614)) Oil filling 72.5 kV 168 quantity VS 123 kV 188 and minimum volume DV6) 170 kV 203 of the diverter switch oil 245 kV 218 compartment 300 kV 240 Table 1 b Notes for tables 1a and 1b: 1) The maximum rated step voltage may be exceeded by 10% due to overexcitation of the transformer if the step capacity is limited to its rated value. 2) Higher step capacities available as special design 3) Forced current division by two parallel winding branches required 4) Applies to tap selector size E 5) In accordance with VDE 0111, part 1: R.m.s. value of the phase-phase voltage for which a piece of equipment is rated for its insulation 6) Minimum volume of oil conservator for oil temperature ϑ = –30 °C... +100 °C: DV = 0,1 VS + 4 (dm3) 7) On request 8) Oil filter unit 0F 100 (combi-filter) required, UbST > 300 kV on request 9) Rated withstand voltages comply with IEC 60214: 1989; unrestricted tests possible up to 1050 kV 1.2|50 or 460 kV, 50 Hz, 1 min. 115/02/01/0 TD 115/03 5 1 General 1.2 Survey 8997470E_01 Fig. 1a Survey of the on-load tap-changer designs (no. of poles, change-over selector, and installation lengths) 6 TD 115/03 115/02/01/0 1 General 8997470E_02 Fig. 1b Survey of the on-load tap-changer designs (no. of poles, change-over selector, and installation lengths) 115/02/01/0 TD 115/03 7 1 General Survey of the basic connection diagrams (figures 2a, 2b, 2c) with designation of the tap selector contact terminals in accord- ance with MR standards. This contact terminal designation corresponds to the specifications in the on-load tap-changer dimensional drawings. Fig. 2a excerpt from 8906164E_1 8 TD 115/03 115/02/01/0 1 General Fig. 2b 8906164D_2 115/02/01/0 TD 115/03 9 1 General Fig. 2c 8906164D_3 10 TD 115/03 115/02/01/0 1 General Examples of connection diagrams (contact designation in acc. w. MR standards) Fig. 3 Example: On-load tap-changer R III 1200 Y–C/D, basic connection diagram 10 19 1 W 115/02/01/0 TD 115/03 11 1 General Fig. 4 Example: On-load tap-changer R III 1200 Y–E, basic connection diagram 14 27 1 G 12 TD 115/03 115/02/01/0 1 General Fig. 5 Example: On-load tap-changer R I 2002–C/D, basic connection diagram 18 35 1 W 115/02/01/0 TD 115/03 13 1 General Fig. 6 Example: On-load tap-changer R I 3003–C/D, basic connection diagram 18 35 1 W 14 TD 115/03 115/02/01/0 2 Technical Data 2 Technical Data 2.1 Rated through-current (Iu), rated step voltage (Ui) and step capacity (PStN) R I 2003 On-load- R III 1200 Y R I 1201 R I 2002 (Special R I 24021) R I 3003 tap-changer design) Iu (A) 700 1200 700 1200 1070 2000 1300 2000 1400 2400 2000 3000 Ui (V) 4000 2500 4000 2500 4000 2200 4000 3000 4000 2500 3000 2000 PStN (kVA) 2800 3000 2800 3000 4280 4400 5200 6000 5600 6000 6000 6000 Table 2 Rated through-currents (Iu), related rated step voltages (Ui) and step capacities (PStN), at highest and lowest rated step voltage of the step capacity curve (see fig. 7 and fig. 8) 1) Note: R I 2402 with forced current division by two parallel winding branches Fig. 7 Step capacities (rated step voltages Ui, rated through- currents Iu) for on-load tap-changer R III 1200 Y, R I 1201, R I 1202 CAUTION: Only applies to network service. When used for 8997510E industrial transformers, please contact us. 115/02/01/0 TD 115/03 15 2 Technical Data 8997510E Fig. 8 Step capacities (rated step voltages Ui, rated through-currents Iu) for on-load tap-changer R I 2002, R I 2003 (= special design), R I 2402, R I 3003. Note: 1) R I 2402 with forced current division by two parallel winding branches. CAUTION: Only applies to network service. When used for industrial transformers, please contact us. 16 TD 115/03 115/02/01/0 2 Technical Data 2.2 Contact life The mean expected contact life of the arcing diverter switch contacts can be estimated based on the relative load (Iu / Ium) as shown in figure 9. Since actual contact life in individual cases depends on many influencing factors while in service, only estimations can be given (not applicable to constant current service). The inspection regulations must be observed. KHW 579-4 Fig. 9 Expected mean contact life under average load n – Number of operations Iu – Rated through-current Ium – Max. rated through-current 115/02/01/0 TD 115/03 17 2 Technical Data 2.3 Rated withstand voltages of the internal insulation Fig. 10 shows diagrams of the voltage stress present on the tap winding of the three primary basic connections of three- pole on-load tap-changers and single-pole on-load tap-changers. When selecting the on-load tap-changer, a check must be made to determine whether the highest stress on the tap selector does not exceed the related rated withstand voltages. Without change-over selector With reversing switch With coarse tap selector in (+) - position With coarse tap selector in (-) - position CAUTION Adhere to the maximum rated 8997560M lightning impulse withstand voltage stress on a0 in mid-position. a0 = Between preselected and selected tapping on the diverter switch a1 = Between tap selector contacts of the winding of one tap position (connected or not) a = Between beginning and end of a tapped winding and, with coarse tap winding, between beginning and end of a coarse tap winding. Note for coarse tapping arrangement in (-) -position of the change-over selector: When stressed with impulse voltage, the permissible withstand voltage „a“ must be adhered to between the end of a coarse tap winding connected with the K tap selector contact and the tap selector contact at the end of the tapped winding of the same phase. b = Between the tap selector contacts of different phases and between change-over selector contacts of different phases, which are connected with the beginning/end of a tapped winding or with a tap selector contact. f = Between diverter switch terminal and ground Additional for coarse tapping arrangement in (+) - position of the change-over selector: c1 = From one (-) -change-over selector contact to terminal of the same phase. c2 = Between (-) -change-over selector contacts of different phases Fig. 10 Rated withstand voltages 18 TD 115/03 115/02/01/0 2 Technical Data Insulation Selector size C Selector size D 1) Selector size E distances kV 1.2/50 µs kV, 50 Hz, 1 min kV 1.2/50 µs kV, 50 Hz, 1 min kV 1.2/50 µs kV, 50 Hz, 1 min Transition resistor max. 150 2) 22 max. 150 2) 22 max. 150 2) 22 R2 ≥ 2.33 Ω a0 Transition resistor max. 150 3) 27 max. 150 3) 27 max. 150 3) 27 R2 < 2.33 Ω a1 150 30 150 30 150 30 a 400 85 500 4) 110 670 180 b 5) 400 100 500 4) 150 670 180 c1 550 180 590 210 820 250 c25) 550 195 590 225 820 280 Table 3 Rated withstand voltages (in kV) of the inner insulation of the selector Note: 1) Selectors in accordance with basic connection diagram 10 09 1 W, 12 11 1 W, 14 13 1 W are realized as 18 09 1 W, 18 11 1 W, 18 13 1 W. Selectors in accordance with basic connection diagram 16 15 1 W und 18 17 1 W are not available. 2) Varistor response voltage at 1.2/50 µs lightning impulse: from 45 kV ( U100%(t)standardized ≠ U75%(t)standardized ) Residual voltage at 3 kA peak current: ≤ 110 kV 3) Varistor response voltage at 1.2/50 µs lightning impulse: from 55 kV ( U100%(t)standardized ≠ U75%(t)standardized ) Residual voltage at 3 kA peak current: ≤ 85 kV 4) Higher values up to 550 kV on request. 5) Not included with on-load tap-changers R I 1201, R I 2002 / 2402, R I 3003 The selector size (ID letters C, D, E) characterizes the internal insulation of the selector, whose rated withstand voltages must be matched to the requirements of the transformer winding. The admissible maximum operating voltage on the individual selector distances corresponds to half the value of the rated short-duration power frequency withstand voltages listed in table 3. 115/02/00/0 TD 115/03 19 3 Appendix 3 Appendix Dimensional drawings On-load tap-changer OILTAP® R III 1200 Y, tap selector size C/D, E...................................................................................... 896722, 897867 On-load tap-changer OILTAP® R I 1201, tap selector size C/D, E........................................................................................... 899753, 899401 On-load tap-changer OILTAP® R I 2002, tap selector size C/D, E........................................................................................... 896721, 897866 On-load tap-changer OILTAP® R I 2402, tap selector size C/D, E........................................................................................... 897490, 897864 On-load tap-changer OILTAP® R I 3003, tap selector size C/D, E........................................................................................... 896720, 897865 Tap selector and change-over selector terminal contacts, tap selector size E...................................................................................... 897868 Installation drawings Tap selector size C/D................................................................................................................................................................................................ 896705 Tap selector size E..................................................................................................................................................................................................... 897873 Additional drawings On-load tap-changer head.................................................................................................................................................................................... 893899 On-load tap-changer cover with mounting flange for pressure relief valve........................................................................................ 895168 Versions of the on-load tap-changer head, swiveling range of gear unit............................................................................................. 896703 Special design for installation in bell-type tanks........................................................................................................................................... 896762 Horizontal drive shaft, tap selector size C/D, E.............................................................................................................................. 896708, 897872 Jumpers for parallel connection of tap selector terminal contacts for on-load tap-changer OILTAP® R I 2002, R I 3003, selector size C/D, E................................................................................................................................................................ 896706, 898713 Tap selector bottom, shielding, tap selector size C/D.................................................................................................................................... 896702 Tap selector bottom, tap selector size E............................................................................................................................................................ 897869 Tie-in resistors, tap selector size C/D.............................................................................................................................. 896707, 898124 - 898135 Potential switch, tap selector size C/D, E......................................................................................................................................... 898136, 898614 Additional drawings for on-load tap-changer................................................................................................................................................ 898826 20 TD 115/03 115/02/01/0 8967227E On-load tap-changer OILTAP® R R III 1200 - C/D, dimension drawing 115/02/01/0 TD 115/03 21 8978677E On-load tap-changer OILTAP® R R III 1200 - E, dimension drawing 22 TD 115/03 115/02/01/0 8997530E On-load tap-changer OILTAP® R R I 1201 - C/D, dimension drawing 115/02/01/0 TD 115/03 23 8994011E On-load tap-changer OILTAP® R R I 1201 - E, dimension drawing 24 TD 115/03 115/02/01/0 8967218E On-load tap-changer OILTAP® R R I 2002 - C/D, dimension drawing 115/02/01/0 TD 115/03 25 8978666E On-load tap-changer OILTAP® R R I 2002 - E, dimension drawing 26 TD 115/03 115/02/01/0 8974905E On-load tap-changer OILTAP® R R I 2402 - C/D, with forced current division with two parallel winding branches, dimension drawing 115/02/01/0 TD 115/03 27 8978646E On-load tap-changer OILTAP® R R I 2402 - E, with forced current division with two parallel winding branches, dimension drawing 28 TD 115/03 115/02/01/0 8967208E On-load tap-changer OILTAP® R R I 3003 - C/D, dimension drawing 115/02/01/0 TD 115/03 29 8978657E On-load tap-changer OILTAP® R R I 3003 - E, dimension drawing 30 TD 115/03 115/02/01/0 8978683E On-load tap-changer OILTAP® R Tap selector size E, tap selector and change-over selector terminal contacts 115/02/01/0 TD 115/03 31 8967056E On-load tap-changer OILTAP® R Tap selector size C/D, installation drawing 32 TD 115/03 115/02/01/0 8978733E On-load tap-changer OILTAP® R Tap selector size E, installation drawing 115/02/01/0 TD 115/03 33 893899AE On-load tap-changer OILTAP® MS, M, R, RM On-load tap-changer head, centric drive 34 TD 115/03 115/02/01/0 8951685E On-load tap-changer OILTAP® MS, M, R, RM With flange for pressure relief valve 115/02/01/0 TD 115/03 35 8967034E On-load tap-changer OILTAP® R Versions of the on-load tap-changer head, swiveling range and drive direction of the gear unit 36 TD 115/03 115/02/01/0 8967627E On-load tap-changer OILTAP® MS, M, R, RM Special design for installation in bell-type tank Lifting device O-Ring 44.2 - 5,7 Suction pipe Drilling hole in sectional plane Transformer cover O-Ring Level traverse Guiding ring with Um = 170 kV, 245 kV, 300 kV Supporting flange Level traverse Z = Guiding pin Drive side of the tap selector 115/02/01/0 TD 115/03 37 8967087E On-load tap-changer OILTAP® MS, M, R, RM Horizontal drive shaft (limit dimensions) Tap selector size C/D, centric drive 38 TD 115/03 115/02/01/0 8978723E On-load tap-changer OILTAP® R Horizontal drive shaft (limit dimensions) Tap selector size E, centric drive 115/02/01/0 TD 115/03 39 8967066E On-load tap-changer OILTAP® R R I 2002, R I 3003, tap selector size C/D Jumpers for parallel connection of tap selector terminal contacts 40 TD 115/03 115/02/01/0 8987131E On-load tap-changer OILTAP® R R I 2002, R I 3003, tap selector size E Jumpers for parallel connection of tap selector terminal contacts 115/02/01/0 TD 115/03 41 8967028E On-load tap-changerOILTAP® R Tap selector size C/D, tap selector bottom shown with the lowest parts connected to the voltage, standard design without grading ring, special design with grading ring 42 TD 115/03 115/02/01/0 8978695E On-load tap-changer OILTAP® R Tap selector size E, tap selector bottom shows lowest parts connected to voltage 115/02/01/0 TD 115/03 43 8967078E On-load tap-changer OILTAP® R Tap selector size C/D, principal arrangement of potential switch and tie-in resistors 44 TD 115/03 115/02/01/0 8981242M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WP, tap selector size C/D, Um = 72.5 kV to 300 kV, 2 x 14 to 2 x 18 resistors 115/02/01/0 TD 115/03 45 8981252M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WP, tap selector size C/D, Um = 72.5 kV to 300 kV, 2 x 3, 2 x 5, to 2 x 13 resistors 46 TD 115/03 115/02/01/0 8981262M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WP, tap selector size C/D, Um = 72.5 kV to 300 kV, 2 x 4, 2 x 6 to 2 x 12 resistors 115/02/01/0 TD 115/03 47 8981272M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WP, tap selector size C/D, Um = 72.5 kV to 300 kV, 3 to 26 resistors 48 TD 115/03 115/02/01/0 8981282M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WR, tap selector size C/D, Um = 72.5 kV to 300 kV, 2 x 14 to 2 x 18 resistors 115/02/01/0 TD 115/03 49 8981292M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WR, tap selector size C/D, Um = 72.5 kV to 300 kV, 2 x 3, 2 x 5, to 2 x 13 resistors 50 TD 115/03 115/02/01/0 8981302M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WR, tap selector size C/D, Um = 72.5 kV to 300 kV, 2 x 4, 2 x 6, to 2 x 12 resistors 115/02/01/0 TD 115/03 51 8981312M On-load tap-changer OILTAP® R Tie-in resistor cylinder R I to WR, tap selector size C/D, Um = 72.5 kV to 300 kV, 3 to 26 resistors 52 TD 115/03 115/02/01/0 8981322M On-load tap-changer OILTAP® R Tie-in resistor cylinder R III 1200 WP, tap selector size C/D, Um = 72.5 kV to 245 kV, 3 x 2 to 3 x 7 resistors 115/02/01/0 TD 115/03 53 8981332M On-load tap-changer OILTAP® R Tie-in resistor cylinder R III 1200 WP, tap selector size C/D, Um = 72.5 kV to 245 kV, 3 x 8 to 3 x 10 resistors 54 TD 115/03 115/02/01/0 8981342M On-load tap-changer OILTAP® R Tie-in resistor cylinder R III 1200 WR, tap selector size C/D, Um = 72.5 kV to 245 kV, 3 x 2 to 3 x 8 resistors 115/02/01/0 TD 115/03 55 8981352M On-load tap-changer OILTAP® R Tie-in resistor cylinder R III 1200 WR, tap selector size C/D, Um = 72.5 kV to 245 kV, 3 x 9 to 3 x 11 resistors 56 TD 115/03 115/02/01/0 8981362M On-load tap-changer OILTAP® R Potential switch R III 1200 WS, R I to WS, tap selector size C/D, Um = 72.5 kV to 300 kV 115/02/01/0 TD 115/03 57 8986142M On-load tap-changer OILTAP® R Potential switch R III 1200 WS, R I to WS, tap selector size E, Um = 72.5 kV to 300 kV 58 TD 115/03 115/02/01/0 8988261E On-load tap-changer OILTAP® R Additional drawings for on-load tap-changer Basic connection diagrams.............................................................. 890616 Tap selector and change-over selector terminal contacts, tap selector size E................................................................................ 897868 Tap selector bottom, shielding, tap selector size C/D........................................................................... 896702 Tap selector bottom, tap selector size E...................................... 897869 Versions of the on-load tap-changer head................................ 896703 Horizontal drive shaft, tap selector size C/D.............................. 896708 Horizontal drive shaft, tap selector size E................................... 897872 Installation drawing, tap selector size C/D................................. 896705 Installation drawing, tap selector size E...................................... 897873 On-load tap-changer head.............................................................. 893899 115/02/01/0 TD 115/03 59 © Maschinenfabrik Reinhausen GmbH Phone +49 941 40 90-0 www.reinhausen.com Falkensteinstrasse 8 Fax +49 941 40 90-111 93059 Regensburg, Germany E-Mail [email protected] Please note: The data in our publications may differ from the data of the devices delivered. We reserve the right to make changes without notice. TD 115/03 en F0019602