Any plumbing fixture used at least ___ a week should retain water in its trap seal. A trap seal ___ is a trap seal protection device or system with a feeder line that releases a sm... Any plumbing fixture used at least ___ a week should retain water in its trap seal. A trap seal ___ is a trap seal protection device or system with a feeder line that releases a small amount of water to a trap when it runs dry to maintain the trap seal. Some codes may require a(n) ___ fitting to be installed at the bottom of the trap seal primer valve outlet port before connection of the feeder line. An electronic design trap seal primer device utilizes a(n) ___ valve to control water flow to single or multiple feeder lines. Fixture connected ___ devices should only be connected to fixtures that have grease-free wastewater. A plumbing ___ is an object or device fastened to a fixture or close to it, that is not essential in itself but that adds to the beauty, convenience, or the effectiveness of the plumbing fixture or appliance. A(n) ___ installation is the installation of a component or device within a wall or depression so that it is flush with the surface face. A(n) ___ backflow preventer is a testable backflow prevention device that consists of two independently acting check valves with an intermediate vent between the checks. ADA bathtubs are required to have a permanent or removable in-tub ___. A journeyworker has the responsibility for the proper location and installation of any type of ___ for plumbing fixtures and plumber installed accessories. A pressure-drop activated trap seal valve uses a(n) ___ flow of water to periodically refill the water trap seal.
Understand the Problem
The question is asking about various plumbing terms and devices that relate to maintaining plumbing systems, specifically focusing on trap seals, valves, and installations. The problems are likely multiple-choice or fill-in-the-blank type questions aimed at plumbing knowledge.
Answer
5. once, 6. primer, 7. cleanout, 8. solenoid, 9. composite, 10. accessory, 11. flush, 12. double check, 13. seat, 14. valve, 15. trickle
["5. Any plumbing fixture used at least once a week should retain water in its trap seal.","6. A trap seal primer is a trap seal protection device or system with a feeder line that releases a small amount of water to a trap when it runs dry to maintain the trap seal.","7. Some codes may require a cleanout fitting to be installed at the bottom of the trap seal primer valve outlet port before connection of the feeder line.","8. An electronic design trap seal primer device utilizes a solenoid valve to control water flow to single or multiple feeder lines.","9. Fixture connected composite devices should only be connected to fixtures that have grease-free wastewater.","10. A plumbing accessory is an object or device fastened to a fixture or close to it, that is not essential in itself but that adds to the beauty, convenience, or the effectiveness of the plumbing fixture or appliance.","11. A flush installation is the installation of a component or device within a wall or depression so that it is flush with the surface face.","12. A double check backflow preventer is a testable backflow prevention device that consists of two independently acting check valves with an intermediate vent between the checks.","13. ADA bathtubs are required to have a permanent or removable in-tub seat.","14. A journeyworker has the responsibility for the proper location and installation of any type of valve for plumbing fixtures and plumber installed accessories.","15. A pressure-drop activated trap seal valve uses a trickle flow of water to periodically refill the water trap seal."]
Answer for screen readers
["5. Any plumbing fixture used at least once a week should retain water in its trap seal.","6. A trap seal primer is a trap seal protection device or system with a feeder line that releases a small amount of water to a trap when it runs dry to maintain the trap seal.","7. Some codes may require a cleanout fitting to be installed at the bottom of the trap seal primer valve outlet port before connection of the feeder line.","8. An electronic design trap seal primer device utilizes a solenoid valve to control water flow to single or multiple feeder lines.","9. Fixture connected composite devices should only be connected to fixtures that have grease-free wastewater.","10. A plumbing accessory is an object or device fastened to a fixture or close to it, that is not essential in itself but that adds to the beauty, convenience, or the effectiveness of the plumbing fixture or appliance.","11. A flush installation is the installation of a component or device within a wall or depression so that it is flush with the surface face.","12. A double check backflow preventer is a testable backflow prevention device that consists of two independently acting check valves with an intermediate vent between the checks.","13. ADA bathtubs are required to have a permanent or removable in-tub seat.","14. A journeyworker has the responsibility for the proper location and installation of any type of valve for plumbing fixtures and plumber installed accessories.","15. A pressure-drop activated trap seal valve uses a trickle flow of water to periodically refill the water trap seal."]
More Information
Trap seals are crucial for maintaining the water barrier that prevents sewer gases from entering the building.
Tips
Ensure that the terms used fit logical and plumbing engineering principles. Using the terms provided, match them logically with the descriptions given.
AI-generated content may contain errors. Please verify critical information