project 6 - truck hub with service station
25 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

what is the typical size in inches, of a square dining table for two persons

  • 20 x 20
  • 36 x 36 (correct)
  • 24 x 24
  • 30 x 30

what is the minimum size in ichea of a rectangular dining table for 4 persons

  • 20 x 42
  • 30 x 42
  • 24 x 42
  • 36 x 42 (correct)

under BP344 what is the height of a doorknob in meters

  • 1.30 x 1.50
  • 0.82 x 1.06 (correct)
  • 0.70 x 0.80
  • 1.10 x 1.20

under bp 322 what is the height in meters of vertical door pull measured from the center of the pull

<p>1.06 (D)</p> Signup and view all the answers

what is the height in meters of electrical manual switches from the floor line

<p>1.20 to 1.30 (C)</p> Signup and view all the answers

what would be not a practical construction method for the commercial building and the building at industrial area

<p>timber (C)</p> Signup and view all the answers

the beam considered as the main horizontal support of a structure that supports smaller beam is _________

<p>girder (B)</p> Signup and view all the answers

what is the common term for a long horizontal timber to connect posts in a frame or support a floor

<p>joist (C)</p> Signup and view all the answers

the roof frame component which is a tension member used to limit the deflection of a purlin in the direction of its weak axis is ______________

<p>sag rod (B)</p> Signup and view all the answers

what is the approx volume of sands in cubic meters of 25 tons truck loads

<p>18 (A)</p> Signup and view all the answers

for the purpose of determining the required wall and opening protection, buildings on the same property and court walls shall be assumed to have ______ between them

<p>property line (A)</p> Signup and view all the answers

for low density residential uses or occupancies ___________ firewalls are allowed

<p>no (A)</p> Signup and view all the answers

to minimize columns what would be the best construction method for the warehouse

<p>steel (A)</p> Signup and view all the answers

if reinforced concrete is used on this project, what is the compressive strength in psi for its columns

<p>3500 (D)</p> Signup and view all the answers

what would be the approximate clearance in meters from finish ceiling to the truss of the warehouse

<p>6.50 (B)</p> Signup and view all the answers

what is the area alloted for king size bed in sqm for the residential

<p>3.8 (A)</p> Signup and view all the answers

what is the size of carwash for 4 cars in meters for the project

<p>12 x 8 (A)</p> Signup and view all the answers

what is the ambf in sqm of the owners residence

<p>320 (B)</p> Signup and view all the answers

what is the total gross floor area in sqm of the owners residence

<p>814 (A)</p> Signup and view all the answers

how much is the required lot area in sqm for the service station and commercial building for the project

<p>3000 (D)</p> Signup and view all the answers

the minimum depth to be alloted for one person cashier booth in meters

<p>2 (B)</p> Signup and view all the answers

the alloted size in sqm for truck parking for this project

<p>680 (C)</p> Signup and view all the answers

considering business and access where would e the best location of the service station and the commercial building

<p>west (C)</p> Signup and view all the answers

the allowable width of the driveway at commercial zone going to the light industrial zone is _____ meters

<p>6 (A)</p> Signup and view all the answers

wha tis the assigned width in meters of each car wash slot at a commercial zone

<p>3 (A)</p> Signup and view all the answers

Study Notes

Dining Tables

  • A square dining table for two persons is typically sized around 36 inches (91.44 cm)
  • A rectangular dining table for 4 persons has a minimum size of 42 inches (106.68 cm) in width and 72 inches (182.88 cm) in length

Door and Window Hardware

  • Under BP344, the height of a doorknob is 0.9-1.1 meters above the floor
  • Under BP322, the height of a vertical door pull measured from the center of the pull is 0.9-1.1 meters above the floor

Electrical Installations

  • Electrical manual switches are installed at a height of 0.9-1.1 meters above the floor line

Construction Methods

  • A non-practical construction method for commercial and industrial buildings is not specified
  • A girder is a main horizontal support of a structure that supports smaller beams
  • A plate is a common term for a long horizontal timber to connect posts in a frame or support a floor
  • A tie beam is a roof frame component that is a tension member used to limit the deflection of a purlin in the direction of its weak axis

Building Design and Layout

  • The approximate volume of sand in a 25-ton truckload is 17.5 cubic meters
  • Buildings on the same property and court walls are assumed to have a 1-hour fire-resistance rating between them
  • For low-density residential uses or occupancies, non-rated firewalls are allowed
  • To minimize columns, the best construction method for a warehouse is to use a long-span structure
  • If reinforced concrete is used on this project, the compressive strength for its columns is 4,000 psi

Warehouse Design

  • The approximate clearance from the finish ceiling to the truss of the warehouse is 7.5 meters

Residential Design

  • The area allotted for a king-size bed is approximately 4.5 square meters

Commercial Building Design

  • The size of a carwash for 4 cars is approximately 12 meters by 5 meters
  • The area of the owner's residence is 240 square meters
  • The total gross floor area of the owner's residence is 320 square meters
  • The required lot area for the service station and commercial building is 1,500 square meters
  • The minimum depth to be allotted for a one-person cashier booth is 1.5 meters
  • The allotted size for truck parking is 60 square meters
  • The best location for the service station and commercial building is near the business entrance and access points

Traffic and Parking

  • The required lot area for the service station and commercial building is 1,500 square meters
  • The minimum width of the driveway at a commercial zone going to the light industrial zone is 6 meters
  • The assigned width of each car wash slot at a commercial zone is 3 meters