When determining the application of FSI and plot coverage regulations, what is taken into consideration?

  • The lowest of the PLR extract/patta and registered ownership document, excluding any encroachment (correct)
  • The sum of the PLR extract/patta and registered ownership document
  • The average of the PLR extract/patta and registered ownership document
  • The highest of the PLR extract/patta and registered ownership document
  • What is the basis for application of setback regulation?

  • The middle boundary of the plot, including any passage
  • The outer boundary of the plot, including any encroachment
  • The inner boundary of the plot, excluding any encroachment (correct)
  • The entire plot area, including any open spaces
  • What is plot coverage expressed as?

  • A fraction of the built-up area to the plot area
  • A ratio of the built-up area to the plot area
  • A percentage of the ratio of the built-up area to the plot area (correct)
  • A proportion of the built-up area to the plot area
  • What is exempted from the computation of plot coverage?

    <p>Floor area mentioned in Annexure XVIII</p> Signup and view all the answers

    What type of building has only front, rear, and interior open spaces?

    <p>All of the above</p> Signup and view all the answers

    What is a contiguous parcel of land enclosed by definite boundaries?

    <p>A site</p> Signup and view all the answers

    What is the maximum FSI allowed in a plot?

    <p>1.5</p> Signup and view all the answers

    What is the minimum plot coverage percentage allowed in a plot?

    <p>70%</p> Signup and view all the answers

    How far should a setback be from the street alignment in a new road?

    <p>From the street alignment</p> Signup and view all the answers

    What is the maximum allowed height of structures like lavatory, lumber room, etc. in a rear set back?

    <p>4.0m</p> Signup and view all the answers

    What is the minimum width of corridor required in a plot?

    <p>As given in the Annexure XVII</p> Signup and view all the answers

    What is the minimum width of internal passage required in a ground floor in CBA?

    <p>1.0m</p> Signup and view all the answers

    What is the minimum plot frontage required for a building?

    <p>4m</p> Signup and view all the answers

    What is the maximum height allowed for a building in this regulation?

    <p>The maximum height is not specified</p> Signup and view all the answers

    What is the minimum set back required for a building abutting a road with a width of 15.25m?

    <p>3.0m</p> Signup and view all the answers

    What is the maximum Floor Space Index (FSI) allowed for a building in this regulation?

    <p>1.5</p> Signup and view all the answers

    What is the minimum percentage of plot coverage required for a building?

    <p>75%</p> Signup and view all the answers

    What type of structures are permissible in the minimum prescribed front, side, and rear setbacks?

    <p>As specified in regulation No. 11</p> Signup and view all the answers