Untitled Quiz
24 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What type of token instrument is mentioned in the document?

  • 'A' Type Token Instrument - Metallic Return (correct)
  • 'D' Type Token Instrument - Hydraulic Return
  • 'B' Type Token Instrument - Electrical Return
  • 'C' Type Token Instrument - Pneumatic Return
  • Which chapter deals with Outdoor Signalling - Installation, Testing and Maintenance of Equipment?

  • Chapter 19 (correct)
  • Chapter 21
  • Chapter 18
  • Chapter 20
  • What is Drg No. 19-D7?

  • Shunt Signal Foundation (correct)
  • Apparatus Case Full Size Foundation
  • Main Signal Post Earthing Arrangement
  • Main Signal Post Foundation
  • What is the topic of Chapter 20?

    <p>Automatic Block Signalling</p> Signup and view all the answers

    What is Drg No. 21-D1?

    <p>Automatic Signalling Scheme With OFC, MSDAC &amp; OC</p> Signup and view all the answers

    How many sheets are there in Drg No. 20-D1?

    <p>3</p> Signup and view all the answers

    What is Drg No. 19-D1?

    <p>Apparatus Case Full Size Foundation</p> Signup and view all the answers

    What is the topic of Chapter 19?

    <p>Outdoor Signalling - Installation, Testing and Maintenance of Equipment</p> Signup and view all the answers

    What is the page number of the drawing for Track Lead Cable Connections in the Indian Railways Signal Engineering Manual (IRSEM) Version 3.0?

    <p>42</p> Signup and view all the answers

    What is the type of token instrument shown in Drg No. 18-D6?

    <p>A ‘A’ Type Token Instrument- Earth Return</p> Signup and view all the answers

    What is the size of the sheet for Drg No.17-D2: Track Circuit Bonding Diagram for Typical 4 Road Station?

    <p>A3 Size</p> Signup and view all the answers

    What is the page number of the Scheme of Power Supply Arrangement for Distributed EI?

    <p>32</p> Signup and view all the answers

    What is the drawing number for Cable Plan for Electric Lifting Barrier (ELB) at Station?

    <p>Drg No.15-D10</p> Signup and view all the answers

    How many sheets are there in Drg No.16-D1: Power Supply Arrangement for Central EI?

    <p>4</p> Signup and view all the answers

    What is the page number of the IB Hut Layout Plan (Double Line/Single Line)?

    <p>45</p> Signup and view all the answers

    What is the purpose of the Filter Unit for Block Circuits?

    <p>To filter out unwanted signals in block circuits</p> Signup and view all the answers

    What is the purpose of the drawings in Appendix II of the IRSEM?

    <p>To provide a detailed guide for signal engineers and technicians</p> Signup and view all the answers

    What is the numbering convention used for the drawings in Appendix II?

    <p>A combination of chapter and drawing numbers</p> Signup and view all the answers

    Who publishes the Signal Engineering Manual?

    <p>Indian Railways Institute of Signal Engineering and Telecommunications, Secunderabad</p> Signup and view all the answers

    What is the primary objective of the IRSEM?

    <p>To ensure reliability, availability, and maintainability of signal systems</p> Signup and view all the answers

    What is the purpose of the disclaimer in Appendix II?

    <p>To inform that the drawings are for guidance only and do not endorse specific equipment or brands</p> Signup and view all the answers

    What is the version of the IRSEM mentioned in the preface?

    <p>Version 3.0</p> Signup and view all the answers

    What should be considered while customizing the drawings in Appendix II?

    <p>Both site conditions and zonal railways practices</p> Signup and view all the answers

    What is the relationship between the drawings in Appendix II and the provisions in the concerned chapter of the SEM?

    <p>The drawings should be read in conjunction with the provisions in the SEM</p> Signup and view all the answers

    Study Notes

    Index of Appendix II: Drawings Booklet of Indian Railways Signal Engineering Manual (IRSEM) Version 3.0

    • The appendix contains drawings for guidance, which can be customized according to site conditions, equipment type and size, and zonal railways practices.

    Drawings and Chapters

    • Chapter 16: Power Supply systems for Signalling Installations

      • Drg No.16-D1: Scheme of Power Supply Arrangement for Distributed EI (Sheets-4)
      • Drg No.16-D2: Power Supply Arrangement for Central EI (Sheets-4)
      • Drg No.16-D3: IPS Arrangement for Interlocked LC Gate & IBS (Sheets-2)
    • Chapter 17: Train Detection - Track Circuits & Axle Counters

      • Drg No.17-D1: Drawing for Track Lead Cable Connections
      • Drg No.17-D2: Track Circuit Bonding Diagram for Typical 4 Road Station (Double Line) (A3 Size)
      • Drg No.17-D3: Cross Bonding in Double Line and Single Line Track Circuits, Earth wire in Single Line
    • Chapter 18: Block Instruments, BPAC & IBS Working

      • Drg No. 18-D1: IB Hut Layout Plan (Double Line/Single Line)
      • Drg No. 18-D2: IB Signalling with MSDAC & OFC (Double Line) (Sheets-2)
      • Drg No. 18-D3: IB Signalling with MSDAC & OFC (Single Line) (Sheets-2)
      • Drg No. 18-D4: Filter Unit for Block Circuits
      • Drg No. 18-D5: Protective Devices for AC Electrified Area of Neales ‘A’ Type Token Instrument- Earth Return
      • Drg No. 18-D6: Protective Devices for AC Electrified Area of Neales ‘A’ Type Token Instrument - Metallic Return
      • Drg No. 18-D7: Double Line Block Working with Protective Device for AC Electrified Area
    • Chapter 19: Outdoor Signalling - Installation, Testing and Maintenance of Equipment

      • Drg No.19-D1: Apparatus Case Full Size Foundation
      • Drg No.19-D2: Apparatus Case Half/Quarter Size Foundation
      • Drg No.19-D3: Main Signal Post Foundation (Sheets-2)
      • Drg No.19-D4: Shunt Signal Foundation
      • Drg No.19-D5: Drawing of Earthing for S&T Installation
      • Drg No.19-D6: Earthing Arrangement for Signals, Location Boxes
      • Drg No.19-D7: Copper Plate Earthing Arrangement
      • Drg No.19-D8: Full Location Wiring Format
      • Drg No.19-D9: Half Location Wiring Format
      • Drg No.19-D10: Signal Markers & Number Plates (Sheets-10)
    • Chapter 20: Automatic Block Signalling

      • Drg No 20-D1: Automatic Signalling Scheme With OFC, MSDAC & OC (sheets-3)
    • Chapter 21: Relay & Electronic Interlocking

      • Drg No.21-D1: S&T Building Plan upto 4 Road Stations
      • Drg No 21-D2: S&T Building Plan for 5 to 8 Road Stations
      • Drg No 21-D3: S&T Building Plan for End Goomties (EI)
      • Drg No 21-D4: ASM Room Layout Plan

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    IRSEM-Appendix II June 2021 PDF

    More Like This

    Use Quizgecko on...
    Browser
    Browser