NBC 2015 - Section 3.2 - 12
40 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

According to the National Building Code of Canada 2015, what is the minimum headroom clearance required in every access to exit, except within the floor area of a storage garage?

  • 100 mm
  • 680 mm
  • 980 mm
  • 1100 mm (correct)
  • According to the National Building Code of Canada 2015, what is the minimum width required for a public corridor?

  • 680 mm
  • 1100 mm (correct)
  • 980 mm
  • 100 mm
  • According to the National Building Code of Canada 2015, what is the minimum unobstructed width required for a corridor used by the public or a corridor serving classrooms or patients’ sleeping rooms?

  • 980 mm
  • 680 mm
  • 100 mm
  • 1100 mm (correct)
  • According to the National Building Code of Canada 2015, what is the maximum length permitted for a dead-end corridor, except for a dead-end corridor that is entirely within a suite?

    <p>6 m</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the minimum depth required for a balcony that is required by Clause (1)(c)?

    <p>1.5 m</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for the fire separation between a public corridor and the remainder of the storey, unless the storey is sprinklered throughout?

    <p>45 min</p> Signup and view all the answers

    When is no fire-resistance rating required for a fire separation between a public corridor and the remainder of the storey?

    <p>If the storey is sprinklered throughout</p> Signup and view all the answers

    When is a fire separation required between a public corridor and the remainder of a storey in a sprinklered floor area?

    <p>If the travel distance from any part of the floor area to an exit is more than 45 m</p> Signup and view all the answers

    How many egress doorways are required for dwelling units?

    <p>1</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for a fire separation between a space containing plumbing fixtures and the remainder of the storey?

    <p>45 min</p> Signup and view all the answers

    Which of the following is a requirement for a door that opens into a public corridor or facility?

    <p>Provide a clear opening of at least 800 mm</p> Signup and view all the answers

    Which of the following is NOT a requirement for door release hardware?

    <p>Be installed not more than 1 200 mm above the finished floor</p> Signup and view all the answers

    In what situation is an egress door from a residential occupancy permitted to be provided with additional devices that require a releasing operation?

    <p>When the devices are readily operable from the inside without the use of keys</p> Signup and view all the answers

    Under what circumstances are locking devices permitted on an egress door in an access to exit?

    <p>When they can be released locally</p> Signup and view all the answers

    What is the minimum run required for tapered treads in a curved flight of stairs that is not required as an exit?

    <p>150 mm</p> Signup and view all the answers

    What is the minimum height at which a window in a public area above the second storey must be protected?

    <p>1,070 mm above the floor</p> Signup and view all the answers

    In a building of residential occupancy, what are the two options for protecting a window in a public area above the second storey?

    <p>Using a non-openable window</p> Signup and view all the answers

    What type of ventilation system should be provided in a building or part of a building where dust, fu...?

    <p>Exhaust ventilation system</p> Signup and view all the answers

    What are the requirements for the exhaust ventilation system mentioned in the text?

    <p>It should be designed in conformance with Part 6</p> Signup and view all the answers

    In which type of building should the exhaust ventilation system be provided according to the text?

    <p>All types of buildings</p> Signup and view all the answers

    Which one of the following is true about the required width of ramps with a slope not more than 1 in 8 for access to exit?

    <p>It should be based on at least 6.1 mm per person</p> Signup and view all the answers

    Which one of the following is true about the required width of a ramp with a slope more than 1 in 8 for access to exit?

    <p>It should be based on at least 9.2 mm per person</p> Signup and view all the answers

    Which one of the following is true about the required width of corridors, doorways, and ramps for access to exit from a floor area used for patients in a Group B, Division 2 occupancy or residents in a Group B, Division 3 occupancy?

    <p>It should be based on at least 18.4 mm per person</p> Signup and view all the answers

    Which one of the following is true about the capacity of stairs in an access to exit?

    <p>It should conform to the requirements for stairs in Sentences 3.4.3.2.(1) to (3)</p> Signup and view all the answers

    Which one of the following is true about the required exit width for an access to exit serving a dance hall or a licensed beverage establishment with an occupant load more than 250 in a building that is not sprinklered throughout?

    <p>At least one half of the required exit width should be provided</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following conditions requires the provision of an additional egress doorway for a room or suite?

    <p>The room or suite is located in a floor area that is not sprinklered throughout and has a travel distance to the nearest egress doorway that exceeds the value in Table 3.3.1.5.-A</p> Signup and view all the answers

    What is the minimum distance that two egress doorways required by the National Building Code of Canada 2015 must be placed apart from each other?

    <p>One third of the maximum overall diagonal dimension of the area to be served</p> Signup and view all the answers

    Which of the following statements is true regarding the maximum travel distance within a room or suite to the nearest egress doorway?

    <p>It must not exceed the maximum travel distances specified in Clauses 3.4.2.5.(1)(a), (b), (c) and (f) for exits</p> Signup and view all the answers

    What is a requirement for a floor area above or below the first storey that has a barrier-free path of travel and is not sprinklered throughout, according to the National Building Code of Canada 2015?

    <p>It must be served by an elevator that is protected against fire and smoke movement</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for fire separations in a floor area above or below the first storey that has a barrier-free path of travel and is not sprinklered throughout, according to the National Building Code of Canada 2015?

    <p>45 minutes</p> Signup and view all the answers

    True or false: A window in a public area above the second storey in a building of residential occupancy must be protected by a barrier or railing.

    <p>True</p> Signup and view all the answers

    True or false: A window in a public area above the second storey in a building of residential occupancy can be non-openable if it is designed to withstand lateral design loads for balcony guards.

    <p>True</p> Signup and view all the answers

    True or false: An exhaust ventilation system designed in conformance with the appropriate requirements of Part 6 must be provided in a building or part of a building where dust, fu

    <p>True</p> Signup and view all the answers

    True or false: The exhaust ventilation system mentioned in the text must comply with the appropriate requirements of Part 6.

    <p>True</p> Signup and view all the answers

    True or false: Locking devices are permitted on an egress door in an access to exit.

    <p>False</p> Signup and view all the answers

    True or false: The capacity of stairs in an access to exit is not a requirement.

    <p>False</p> Signup and view all the answers

    True or false: An egress doorway for a room or suite requires an additional device that requires a releasing operation.

    <p>False</p> Signup and view all the answers

    True or false: The exhaust ventilation system should be provided in a building or part of a building where dust, fu

    <p>True</p> Signup and view all the answers

    True or false: A window in a public area above the second storey must be protected at a minimum height of 1,070 mm above the floor.

    <p>True</p> Signup and view all the answers

    True or false: A floor area above or below the first storey that has a barrier-free path of travel and is not sprinklered throughout requires a minimum fire-resistance rating.

    <p>True</p> Signup and view all the answers

    More Like This

    NBC 2015 - Section 3.2 - 01
    50 questions
    NBC 2015 - Section 3.2 - 02
    30 questions
    NBC 2015 - Section 3.2 - 03
    40 questions
    NBC 2015 - Section 3.2 - 05
    40 questions
    Use Quizgecko on...