NBC 2015 - Section 3.2 - 02
30 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which type of construction is permitted for a building facing three streets and having a maximum area of 2,400 m2?

  • Combustible or noncombustible construction used singly
  • Combustible or noncombustible construction used in combination (correct)
  • Noncombustible construction only
  • Combustible construction only
  • What is the maximum building area allowed for a Group A, Division 2 building with a building height of 1 storey and facing one street?

  • 1,000 m2
  • 2,400 m2
  • 800 m2 (correct)
  • 4,800 m2
  • What is the minimum fire-resistance rating required for floor assemblies if they are of combustible construction?

  • 1 h
  • 2 h
  • 45 min (correct)
  • 30 min
  • In a Group A, Division 3 building, what is the minimum fire-resistance rating required for mezzanines?

    <p>1 h</p> Signup and view all the answers

    What is the maximum building area allowed for a Group A, Division 2 building with a building height of 2 storeys and facing 2 streets?

    <p>500 m2</p> Signup and view all the answers

    Which type of construction is permitted for a building classified as Group A, Division 1, One Storey, Sprinklered?

    <p>Noncombustible construction</p> Signup and view all the answers

    Which type of construction is permitted for a building classified as Group A, Division 2, Any Height, Any Area, Sprinklered?

    <p>Noncombustible construction</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for floor assemblies in a building classified as Group A, Division 2, Any Height, Any Area, Sprinklered?

    <p>2 h</p> Signup and view all the answers

    What is the maximum building height permitted for a building classified as Group A, Division 2, up to 6 Storeys, Any Area, Sprinklered?

    <p>6 storeys</p> Signup and view all the answers

    What is the maximum building area permitted for a building classified as Group A, Division 2, up to 2 Storeys?

    <p>The value in Table 3.2.2.25</p> Signup and view all the answers

    Which type of construction is permitted for a Group A, Division 3 building?

    <p>Combustible or noncombustible construction</p> Signup and view all the answers

    Under what conditions can a Group A, Division 4 building be of combustible construction?

    <p>If the occupant load is less than 1,500</p> Signup and view all the answers

    Which type of construction is required for a Group B, Division 1 building that is not sprinklered?

    <p>Noncombustible construction</p> Signup and view all the answers

    What is the maximum building area allowed for a Group B, Division 1 building that is 3 storeys in height?

    <p>8,000 m2</p> Signup and view all the answers

    Which type of construction is required for a Group B, Division 2 building that is not sprinklered?

    <p>Noncombustible construction</p> Signup and view all the answers

    What is the fire-resistance rating required for floor assemblies in a Group B, Division 2 building?

    <p>Not less than 1 h</p> Signup and view all the answers

    What is the maximum building height allowed for a Group B, Division 2 building?

    <p>2 storeys</p> Signup and view all the answers

    What is the maximum building area allowed for a 2-storey Group B, Division 2 building?

    <p>1,600 m2</p> Signup and view all the answers

    What type of construction is permitted for the building in Sentence (1)?

    <p>Both combustible and noncombustible construction</p> Signup and view all the answers

    What is the minimum fire-resistance rating required for mezzanines in a Group B, Division 2 building?

    <p>Not less than 45 min</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following is a requirement for a building classified as Group A, Division 1, Any Height, Any Area, Sprinklered?

    <p>The building must be of noncombustible construction.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following is a requirement for a building classified as Group A, Division 1, One Storey, Limited Area, Sprinklered?

    <p>The building must be sprinklered throughout.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, what is the maximum building area permitted for a building classified as Group A, Division 1, One Storey, Limited Area, Sprinklered?

    <p>600 m2</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following is a requirement for a building classified as Group A, Division 1, One Storey, Limited Area, Sprinklered?

    <p>The building must not have any occupancy above or below the auditorium.</p> Signup and view all the answers

    According to the National Building Code of Canada 2015, which of the following is a requirement for a building classified as Group A, Division 1, One Storey, Limited Area, Sprinklered?

    <p>The building must have an occupant load of not more than 600.</p> Signup and view all the answers

    Which one of the following statements is true about a building classified as Group A, Division 3?

    <p>It must be of noncombustible construction.</p> Signup and view all the answers

    Which one of the following statements is true about the maximum building area for a building classified as Group A, Division 3, up to 2 storeys?

    <p>The maximum building area is 5,000 m2 if facing 2 streets.</p> Signup and view all the answers

    Which one of the following statements is true about the fire-resistance rating for mezzanines in a building classified as Group A, Division 3?

    <p>Mezzanines must have a fire-resistance rating of at least 1 hour.</p> Signup and view all the answers

    Which one of the following statements is true about the building area limit for a sprinklered building classified as Group A, Division 3, up to 2 storeys?

    <p>The building area limit is 6,000 m2 if 2 storeys in building height.</p> Signup and view all the answers

    Which one of the following statements is true about the fire-resistance rating for loadbearing walls, columns, and arches in a building classified as Group A, Division 3, one storey?

    <p>They must have a fire-resistance rating of at least 45 minutes.</p> Signup and view all the answers