Podcast
Questions and Answers
Which type of occupancy is allowed for a Group B, Division 1 major occupancy?
Which type of occupancy is allowed for a Group B, Division 1 major occupancy?
- A high-hazard industrial occupancy
- A contained use area (correct)
- A mercantile occupancy
- Sleeping accommodation
What is the maximum building area allowed for a Group B, Division 1 major occupancy if it includes a medium-hazard industrial occupancy?
What is the maximum building area allowed for a Group B, Division 1 major occupancy if it includes a medium-hazard industrial occupancy?
- 6,400 m2 (correct)
- 5,000 m2
- 10,000 m2
- 8,000 m2
What is the maximum occupant load allowed for the impeded egress zone in a Group B, Division 1 major occupancy?
What is the maximum occupant load allowed for the impeded egress zone in a Group B, Division 1 major occupancy?
- 100 (correct)
- 200
- 50
- 75
What is the maximum building height allowed for a Group B, Division 1 major occupancy?
What is the maximum building height allowed for a Group B, Division 1 major occupancy?
Which of the following occupancies is not allowed for a Group B, Division 1 major occupancy?
Which of the following occupancies is not allowed for a Group B, Division 1 major occupancy?
According to the National Building Code of Canada 2015, which of the following is NOT considered a major occupancy for the purposes of this Subsection?
According to the National Building Code of Canada 2015, which of the following is NOT considered a major occupancy for the purposes of this Subsection?
According to the National Building Code of Canada 2015, what is the maximum height of a crawl space for it to be considered as a basement?
According to the National Building Code of Canada 2015, what is the maximum height of a crawl space for it to be considered as a basement?
According to the National Building Code of Canada 2015, what is the minimum percentage of the building perimeter that needs to be located within 15 m of a street for a building to be considered as facing 2 streets?
According to the National Building Code of Canada 2015, what is the minimum percentage of the building perimeter that needs to be located within 15 m of a street for a building to be considered as facing 2 streets?
According to the National Building Code of Canada 2015, what type of construction is required for an exterior balcony?
According to the National Building Code of Canada 2015, what type of construction is required for an exterior balcony?
According to the National Building Code of Canada 2015, what type of construction is required for a roof-top enclosure for elevator machinery or a service room?
According to the National Building Code of Canada 2015, what type of construction is required for a roof-top enclosure for elevator machinery or a service room?
Which of the following is NOT considered a storey in calculating the building height?
Which of the following is NOT considered a storey in calculating the building height?
Which of the following conditions must be met for a space above a mezzanine to be excluded when calculating the building height?
Which of the following conditions must be met for a space above a mezzanine to be excluded when calculating the building height?
Which of the following is true about the calculation of building height for mezzanines?
Which of the following is true about the calculation of building height for mezzanines?
What is the maximum height of partitions or subdividing walls above a mezzanine floor in order for the space above the mezzanine to be excluded when calculating the building height?
What is the maximum height of partitions or subdividing walls above a mezzanine floor in order for the space above the mezzanine to be excluded when calculating the building height?
When is the space above a mezzanine considered a storey in calculating the building height?
When is the space above a mezzanine considered a storey in calculating the building height?
Which of the following is true about the minimum precautions against fire spread and collapse for a building that extends more than one storey below the adjoining finished ground level?
Which of the following is true about the minimum precautions against fire spread and collapse for a building that extends more than one storey below the adjoining finished ground level?
In a building up to 2 storeys in building height, when is a roof assembly permitted to be of heavy timber construction?
In a building up to 2 storeys in building height, when is a roof assembly permitted to be of heavy timber construction?
Which of the following buildings is exempted from having a roof assembly with a fire-resistance rating?
Which of the following buildings is exempted from having a roof assembly with a fire-resistance rating?
When is an automatic sprinkler system required to be installed throughout a building?
When is an automatic sprinkler system required to be installed throughout a building?
Which of the following is exempted from installing an automatic sprinkler system throughout a building?
Which of the following is exempted from installing an automatic sprinkler system throughout a building?
Which of the following is true about platforms intended solely for periodic inspection and elevated maintenance catwalks?
Which of the following is true about platforms intended solely for periodic inspection and elevated maintenance catwalks?
What is the maximum area of an enclosed space permitted above a mezzanine, without obstructing visual communication between the open space above the mezzanine and the room in which it is located?
What is the maximum area of an enclosed space permitted above a mezzanine, without obstructing visual communication between the open space above the mezzanine and the room in which it is located?
Under what conditions is a service space not considered a storey?
Under what conditions is a service space not considered a storey?
What are the requirements for a basement used primarily as a storage garage to be considered as a separate building?
What are the requirements for a basement used primarily as a storage garage to be considered as a separate building?
What are the requirements for the exterior wall of a basement to be penetrated by openings without closures?
What are the requirements for the exterior wall of a basement to be penetrated by openings without closures?
Which of the following structures does not require fire protection in accordance with the National Building Code of Canada 2015?
Which of the following structures does not require fire protection in accordance with the National Building Code of Canada 2015?
What is the purpose of the fire separation requirements for floor assemblies in a mezzanine?
What is the purpose of the fire separation requirements for floor assemblies in a mezzanine?
In a building with multiple major occupancies, which set of requirements apply to the whole building?
In a building with multiple major occupancies, which set of requirements apply to the whole building?
What is the maximum width of steel lintels above openings that do not require fire protection?
What is the maximum width of steel lintels above openings that do not require fire protection?
What is the purpose of protecting a structure that cannot be identified with the characteristics of a building?
What is the purpose of protecting a structure that cannot be identified with the characteristics of a building?
True or false: A roof-top enclosure provided for elevator machinery shall be considered as a storey in calculating the building height.
True or false: A roof-top enclosure provided for elevator machinery shall be considered as a storey in calculating the building height.
True or false: Space under tiers of seats in a building of the arena type shall be considered as adding to the building height.
True or false: Space under tiers of seats in a building of the arena type shall be considered as adding to the building height.
True or false: The space above a mezzanine must always be considered as a storey in calculating the building height.
True or false: The space above a mezzanine must always be considered as a storey in calculating the building height.
True or false: Platforms intended solely for periodic inspection and elevated maintenance catwalks are considered as floor assemblies or mezzanines for the purpose of calculating building height, regardless of their use or construction materials?
True or false: Platforms intended solely for periodic inspection and elevated maintenance catwalks are considered as floor assemblies or mezzanines for the purpose of calculating building height, regardless of their use or construction materials?
True or false: The space above a mezzanine can include an enclosed space whose area does not exceed 10% of the open area of the room, as long as it does not obstruct visual communication between the open space above the mezzanine and the room?
True or false: The space above a mezzanine can include an enclosed space whose area does not exceed 10% of the open area of the room, as long as it does not obstruct visual communication between the open space above the mezzanine and the room?
True or false: A service space that includes facilities for maintenance and operations pertaining to building services is always considered a storey, regardless of its conformity to certain articles and sentences?
True or false: A service space that includes facilities for maintenance and operations pertaining to building services is always considered a storey, regardless of its conformity to certain articles and sentences?
True or false: If a building is erected entirely below the adjoining finished ground level and extends more than one storey below that ground level, the basements shall be sprinklered throughout.
True or false: If a building is erected entirely below the adjoining finished ground level and extends more than one storey below that ground level, the basements shall be sprinklered throughout.
True or false: If the first storey of a building is not required to be sprinklered, sprinklers are not required in the storey immediately below the first storey.
True or false: If the first storey of a building is not required to be sprinklered, sprinklers are not required in the storey immediately below the first storey.
True or false: An automatic sprinkler system is required to be installed throughout a building regulated by one or more of the specified articles, unless permitted by Sentence (2).
True or false: An automatic sprinkler system is required to be installed throughout a building regulated by one or more of the specified articles, unless permitted by Sentence (2).
True or false: The floor assembly of a mezzanine that is considered as a storey in calculating the building height must meet the fire separation requirements for floor assemblies stated in Articles 3.2.2.20. to 3.2.2.90.
True or false: The floor assembly of a mezzanine that is considered as a storey in calculating the building height must meet the fire separation requirements for floor assemblies stated in Articles 3.2.2.20. to 3.2.2.90.
True or false: A structure that cannot be identified with the characteristics of a building must be protected against fire spread and collapse in accordance with good fire protection engineering practice.
True or false: A structure that cannot be identified with the characteristics of a building must be protected against fire spread and collapse in accordance with good fire protection engineering practice.
True or false: Fire protection is not required for steel lintels above openings less than 2 m wide in loadbearing walls and less than 3 m wide in non-loadbearing walls.
True or false: Fire protection is not required for steel lintels above openings less than 2 m wide in loadbearing walls and less than 3 m wide in non-loadbearing walls.
True or false: If one major occupancy is located above another major occupancy, the fire-resistance rating of the floor assembly between the major occupancies shall be determined on the basis of the requirements of this Subsection for the lower major occupancy.
True or false: If one major occupancy is located above another major occupancy, the fire-resistance rating of the floor assembly between the major occupancies shall be determined on the basis of the requirements of this Subsection for the lower major occupancy.
True or false: A building that is wholly constructed in accordance with the building area and construction requirements of Article 3.2.2.50. shall not contain a) Group A, Division 2 and Group E major occupancies above the second storey, or b) a storage garage above the third storey.
True or false: A building that is wholly constructed in accordance with the building area and construction requirements of Article 3.2.2.50. shall not contain a) Group A, Division 2 and Group E major occupancies above the second storey, or b) a storage garage above the third storey.
True or false: A building that is wholly constructed in accordance with the building area and construction requirements of Article 3.2.2.58. shall not contain a) Group A, Division 2, Group E, and Group F, Division 2 or 3 major occupancies above the second storey, or b) a storage garage above the third storey.
True or false: A building that is wholly constructed in accordance with the building area and construction requirements of Article 3.2.2.58. shall not contain a) Group A, Division 2, Group E, and Group F, Division 2 or 3 major occupancies above the second storey, or b) a storage garage above the third storey.
True or false: A Group B, Division 1 major occupancy can include sleeping accommodation.
True or false: A Group B, Division 1 major occupancy can include sleeping accommodation.
True or false: The occupant load of the impeded egress zone in a Group B, Division 1 major occupancy can be more than 100.
True or false: The occupant load of the impeded egress zone in a Group B, Division 1 major occupancy can be more than 100.
True or false: The building area of a Group B, Division 1 major occupancy can be more than 6,400 m2 if the building includes a medium-hazard industrial occupancy.
True or false: The building area of a Group B, Division 1 major occupancy can be more than 6,400 m2 if the building includes a medium-hazard industrial occupancy.
True or false: The impeded egress zone in a Group B, Division 1 major occupancy can extend beyond the boundaries of the fire compartment it is located in.
True or false: The impeded egress zone in a Group B, Division 1 major occupancy can extend beyond the boundaries of the fire compartment it is located in.
True or false: A Group B, Division 1 major occupancy can include a high-hazard industrial occupancy.
True or false: A Group B, Division 1 major occupancy can include a high-hazard industrial occupancy.