What purpose does the inflatable garment serve when connected to the Air Pulse Generator?

  • It acts as a barrier to external elements.
  • It provides continuous warmth to the chest.
  • It delivers pulsations to the chest wall. (correct)
  • It assists with the patient's mobility during treatment.
  • Which of the following describes the difference between the Classic Line and C3® Garment Line?

  • Classic Line garments are unsuitable for washing, while C3® garments are washable. (correct)
  • C3® Garment Line includes only full vests, while Classic Line includes various sizes.
  • C3® garments are designed for more advanced medical uses than Classic Line.
  • Classic Line garments can only be used at home, while C3® can be used in hospitals.
  • What is an important safety precaution when using the Vest® Airway Clearance System?

  • Always use it without any clothing for better effectiveness.
  • Disconnect the power cord when adjusting the settings.
  • Wear a single layer of cotton clothing beneath the garment. (correct)
  • Change prescribed settings only with physician approval.
  • What is the purpose of the contour foam accessory?

    <p>To offer additional comfort for patients with specific medical devices.</p> Signup and view all the answers

    How frequently has the Vest® Airway Clearance System been prescribed for use?

    <p>A specific number of times per day as determined by a physician.</p> Signup and view all the answers

    What should patients do if they experience nausea during therapy?

    <p>Take breaks during therapy.</p> Signup and view all the answers

    Which feature allows the user to pause or resume therapy without using the control panel?

    <p>Remote Control</p> Signup and view all the answers

    What safety precaution should patients with external ports or equipment take before starting therapy?

    <p>Cushion the site and support the equipment.</p> Signup and view all the answers

    Which component of the Vest® Airway Clearance System controls the inflatable garment?

    <p>Air Pulse Generator</p> Signup and view all the answers

    What symptom should patients avoid during therapy, particularly after eating?

    <p>Nausea</p> Signup and view all the answers

    What does the Main Menu display when the Air Pulse Generator is powered on?

    <p>Available options for therapy selection</p> Signup and view all the answers

    Which part of the Vest® Airway Clearance System is used to connect the inflatable garment to the Air Pulse Generator?

    <p>Air Hoses</p> Signup and view all the answers

    How can a user activate features or functions on the Air Pulse Generator?

    <p>By using the ON/OFF controls and the arrow buttons.</p> Signup and view all the answers

    What is the primary purpose of The Vest® Airway Clearance System?

    <p>To assist in airway clearance therapy</p> Signup and view all the answers

    Which condition would NOT be an appropriate indication for using The Vest® Airway Clearance System?

    <p>Mild asthma attack</p> Signup and view all the answers

    According to the guidelines, which professional organization describes indications for airway clearance therapy?

    <p>American Association of Respiratory Care (AARC)</p> Signup and view all the answers

    What type of information is highlighted using boldface text in the manual?

    <p>Special data or important instructions</p> Signup and view all the answers

    What does a WARNING symbol indicate in The Vest® manual?

    <p>Situations that may affect safety</p> Signup and view all the answers

    Which of the following is NOT a function of The Vest® Airway Clearance System?

    <p>Applying continuous positive airway pressure</p> Signup and view all the answers

    What might be a possible outcome when using The Vest® Airway Clearance System for a patient with atelectasis?

    <p>Improvement in mucus clearance</p> Signup and view all the answers

    What happens if the unit is left in pause mode for 10 minutes?

    <p>The unit will turn off.</p> Signup and view all the answers

    What is indicated by Type B equipment with an F-type applied part according to EN 60601-1?

    <p>Designates a specific electrical safety standard</p> Signup and view all the answers

    What is the first step to begin a treatment session after turning the unit on?

    <p>Press the ON button again.</p> Signup and view all the answers

    Which action must be taken to end the treatment session before it is completed?

    <p>Press the OFF button twice.</p> Signup and view all the answers

    What occurs when the OFF button is pressed twice during a treatment session?

    <p>The 'Incomplete' message shows on the screen.</p> Signup and view all the answers

    What should be done after a treatment session is completed?

    <p>Unplug the system from the power source.</p> Signup and view all the answers

    How can you create a new program mode for The Vest® system?

    <p>Press the ON button, then the DOWN arrow below New Pgm.</p> Signup and view all the answers

    What does the 'Session Complete' message indicate?

    <p>The pulsations have finished and the garment is deflated.</p> Signup and view all the answers

    What is a warning associated with changing the prescribed settings on The Vest® system?

    <p>It can lead to personal injury.</p> Signup and view all the answers

    What occurs after the 'Session Complete' message is displayed?

    <p>The inflatable garment deflates.</p> Signup and view all the answers

    What is the maximum number of programming points that can be set within a single therapy session using the New Program mode?

    <p>8 points</p> Signup and view all the answers

    What is the purpose of the Cough Pause feature?

    <p>To remind the user to cough at scheduled intervals.</p> Signup and view all the answers

    Which button is pressed to access programming options for Program A or Program B?

    <p>Down arrow below PGM A NEW or PGM B NEW</p> Signup and view all the answers

    What happens if a zero (0) time is set for the Cough Pause Reminder duration?

    <p>The Cough Pause feature will turn off.</p> Signup and view all the answers

    How should the settings be adjusted if they do not match the prescribed treatment for Programming Point 1?

    <p>Modify settings using Up and Down arrow buttons.</p> Signup and view all the answers

    What should be done before changing any prescribed settings on the device?

    <p>Consult your physician.</p> Signup and view all the answers

    To select the pause duration for coughs, which button should be pressed?

    <p>The UP or DOWN arrow button</p> Signup and view all the answers

    Study Notes

    Indications for Use

    • Designed for airway clearance therapy through external manipulation of the thorax.
    • Guidelines by the American Association of Respiratory Care (AARC) indicate therapy for retained secretions, difficulties in secretion clearance, or atelectasis caused by mucus plugging.
    • Also, indicated for promoting bronchial drainage and collecting mucus for diagnostic evaluation.

    Features

    • Air Pulse Generator: controls the inflatable garment, providing pulsations to the chest wall.
    • Control Panel: includes ON/OFF buttons and arrow buttons for function activation.
    • Remote Control: optional device to pause/resume therapy instead of using the Control Panel.
    • Inflatable Garments: available as Chest Vest, Full Vest, or Wrap Vest, specifically fitted for the patient.
    • Power Cord: connects the Air Pulse Generator to a power outlet.
    • Contour Foam: optional accessory for patient comfort around medical devices such as catheters.

    Safety Instructions

    • Caution against nausea, dizziness, or headache during therapy; recommended to avoid therapy immediately after eating.
    • Advisories for patients with external ports or equipment to cushion the sites during therapy.
    • Important to consult a physician regarding therapy for patients with breast implants.

    Instructions for Use

    • Overall usage must align with physician’s prescription, including the frequency of use.
    • A single layer of cotton clothing is recommended beneath the garment to prevent static charge.
    • To initiate treatment: press the ON button, monitor treatment time, and use the OFF button to pause/resume.
    • If therapy needs to conclude early, press the OFF button twice; the inflatable garment will deflate.
    • After completing a session: unplug the device and remove Air Hoses from the garment.

    Programming Options

    • New Program mode enables programming of up to eight different settings for Frequency, Pressure, and treatment Time.
    • Cough Pause feature allows for reminders to cough during therapy sessions.
    • Programming requires confirmation with a physician prior to any adjustments to avoid personal injury.

    Maintenance and Safety Reminder

    • Regularly review functions and settings to ensure proper usage and effectiveness.
    • Always prioritize safety precautions as indicated in the manual to prevent patient harm or equipment failure.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the usage and indications for the Vest® Airway Clearance System, Model 105. Learn about the clinical practices and guidelines established by the AARC for airway clearance therapy, including how to effectively use this important medical equipment.