What is the primary reason for conducting a visual inspection of the load?

  • To identify any obvious damage or staining on the load (correct)
  • To check for excessive wetness in the items
  • To ensure the correct operating cycle was selected
  • To verify the documentation of the cleaning process
  • What should be done if a small percentage of RMDs in a load did not get cleaned and/or dried effectively?

  • The entire load should be returned for reprocessing (correct)
  • The load can be released to the IAP room
  • The quality control team should be notified
  • Only the affected RMDs should be reprocessed
  • What is the purpose of the quality checks for manually cleaned devices?

  • To ensure the devices were properly disassembled
  • To identify any visible soil or staining on the devices (correct)
  • To verify the correct operating cycle was used
  • To document the cleaning process
  • Why is it necessary to ensure the correct operating cycle is selected for the load?

    <p>To ensure the load meets the specifications for the devices being processed</p> Signup and view all the answers

    What should be done if an item was handled incorrectly or immersed in fluid when it should not have been?

    <p>It should be documented and reported to the line manager</p> Signup and view all the answers

    What should be done to ensure the cleanliness of devices in a device set?

    <p>Inspect devices separately and check all areas, including box joints, serrations, and crevices</p> Signup and view all the answers

    Why is it essential to check the channel of cannulated devices?

    <p>To ensure the channel is clear of debris</p> Signup and view all the answers

    What is the primary purpose of checking for free movement of all parts and non-sticking joints in devices?

    <p>To verify the devices are functioning correctly before use</p> Signup and view all the answers

    What is the purpose of using a diathermy pin point tester on insulated devices?

    <p>To inspect the insulation coating for damage</p> Signup and view all the answers

    What is the result of scanning a barcode label in the IAP room?

    <p>It produces a unique barcode label with a serial number specific to the tray</p> Signup and view all the answers

    What should be done with devices that are damaged, incomplete, or malfunctioning?

    <p>Report them to the supervisor</p> Signup and view all the answers

    Why is it essential to check all screws on jointed RMD for tightness?

    <p>To prevent loose screws from causing damage during cleaning</p> Signup and view all the answers

    Why is it important to check the hinges of devices, such as artery forceps and clamps?

    <p>To ensure they have ease of movement</p> Signup and view all the answers

    What is the purpose of a track and trace system in a CSSD?

    <p>To track and locate devices during the decontamination process</p> Signup and view all the answers

    What is an alternative to a computerized track and trace system in a CSSD?

    <p>A manual system</p> Signup and view all the answers