Surgical Device Inspection and Testing
15 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the primary reason for conducting a visual inspection of the load?

  • To identify any obvious damage or staining on the load (correct)
  • To check for excessive wetness in the items
  • To ensure the correct operating cycle was selected
  • To verify the documentation of the cleaning process
  • What should be done if a small percentage of RMDs in a load did not get cleaned and/or dried effectively?

  • The entire load should be returned for reprocessing (correct)
  • The load can be released to the IAP room
  • The quality control team should be notified
  • Only the affected RMDs should be reprocessed
  • What is the purpose of the quality checks for manually cleaned devices?

  • To ensure the devices were properly disassembled
  • To identify any visible soil or staining on the devices (correct)
  • To verify the correct operating cycle was used
  • To document the cleaning process
  • Why is it necessary to ensure the correct operating cycle is selected for the load?

    <p>To ensure the load meets the specifications for the devices being processed</p> Signup and view all the answers

    What should be done if an item was handled incorrectly or immersed in fluid when it should not have been?

    <p>It should be documented and reported to the line manager</p> Signup and view all the answers

    What should be done to ensure the cleanliness of devices in a device set?

    <p>Inspect devices separately and check all areas, including box joints, serrations, and crevices</p> Signup and view all the answers

    Why is it essential to check the channel of cannulated devices?

    <p>To ensure the channel is clear of debris</p> Signup and view all the answers

    What is the primary purpose of checking for free movement of all parts and non-sticking joints in devices?

    <p>To verify the devices are functioning correctly before use</p> Signup and view all the answers

    What is the purpose of using a diathermy pin point tester on insulated devices?

    <p>To inspect the insulation coating for damage</p> Signup and view all the answers

    What is the result of scanning a barcode label in the IAP room?

    <p>It produces a unique barcode label with a serial number specific to the tray</p> Signup and view all the answers

    What should be done with devices that are damaged, incomplete, or malfunctioning?

    <p>Report them to the supervisor</p> Signup and view all the answers

    Why is it essential to check all screws on jointed RMD for tightness?

    <p>To prevent loose screws from causing damage during cleaning</p> Signup and view all the answers

    Why is it important to check the hinges of devices, such as artery forceps and clamps?

    <p>To ensure they have ease of movement</p> Signup and view all the answers

    What is the purpose of a track and trace system in a CSSD?

    <p>To track and locate devices during the decontamination process</p> Signup and view all the answers

    What is an alternative to a computerized track and trace system in a CSSD?

    <p>A manual system</p> Signup and view all the answers

    More Like This

    Surgical Device Inspection and Testing
    18 questions
    Sterilization and Inspection of Surgical Devices
    20 questions
    Surgical Device Inspection and Testing
    29 questions
    Surgical Packaging and Sterilization
    24 questions
    Use Quizgecko on...
    Browser
    Browser