Steam Management in HDS Unit Operations
10 Questions
1 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What happens to the stripper tower when the 180 psig steam flow is lost?

  • The stripper tower will be shut down automatically.
  • The stripper tower will continue to function normally.
  • The stripping capability of the stripper tower will be lost. (correct)
  • The stripper tower will become overheated.
  • If the diesel product from the stripper goes off-spec, where should it be routed?

  • To the Stripper Feed Preheater (13EX-2339).
  • To the re-run tank.
  • To the slop tank.
  • To Tank TK-314. (correct)
  • Which step involves venting steam traps to the atmosphere?

  • Step 6
  • Step 5
  • Step 8 (correct)
  • Step 10
  • What is the purpose of cracking open the low-point bleed at FC-0171 stripping steam control valve?

    <p>To prevent condensate buildup. (B)</p> Signup and view all the answers

    What should be done if the 180 psig steam supply is not returned to service quickly?

    <p>Shut down the unit as per SOP-3HDS-201 Normal Unit Shutdown procedure. (C)</p> Signup and view all the answers

    In the event of a loss of 180 psig steam to the #3 HDS Unit, what is the immediate action to be taken regarding feed rates?

    <p>Decrease feed rates to the #3 HDS Unit. (A)</p> Signup and view all the answers

    Which piece of equipment utilizes 180 psig steam primarily during decoking?

    <p>13HT-101 Charge Heater (C)</p> Signup and view all the answers

    Which of the following is NOT a primary user of 180 psig steam in the #3 HDS Unit?

    <p>De-ethanizer Tower (B)</p> Signup and view all the answers

    What is the primary concern related to a loss of steam in the #3 HDS Unit?

    <p>All of the above (D)</p> Signup and view all the answers

    In the event of a steam loss, what should the Console Operator do?

    <p>Notify the Shift Supervisor, Unit Supervisor, and other associated Units. (C)</p> Signup and view all the answers

    Flashcards

    Loss of Steam

    The situation when 180 psig steam flow is lost to the Stripper Tower, impacting its ability to operate properly.

    Off-Spec Products

    Products produced that do not meet quality specifications due to loss of steam in the Stripper Tower.

    Bleed Low-Point

    A procedure to crack open low-point bleeds on steam lines to prevent condensate buildup.

    Emergency Actions

    Specific steps to manage equipment and products in response to a loss of steam.

    Signup and view all the flashcards

    Unit Shutdown Procedure

    The established protocol for safely shutting down the unit if the steam supply is not restored quickly.

    Signup and view all the flashcards

    Immediate Emergency Actions

    Steps to respond quickly to a steam loss emergency.

    Signup and view all the flashcards

    Notification process

    Informing key personnel during a steam loss event.

    Signup and view all the flashcards

    Feed rate reduction

    Decrease the input flow to the #3 HDS Unit when steam is lost.

    Signup and view all the flashcards

    Temperature monitoring

    Keeping track of temperatures in the Stripper Tower after steam loss.

    Signup and view all the flashcards

    More Like This

    Use Quizgecko on...
    Browser
    Browser