  1. Walls that separate sleeping units in the same building must comply with the provisions for

a. Fire partitions

  1. The basement walls, exterior walls, floor, roof and any other building elements that enclose conditioned space or provide a boundary between conditioned space and exempt or unconditioned space is the definition of_________.

Building thermal envelope

  1. Doors, when fully opened, shall not reduce the required width by more than how many inches?

7

  1. Excluding exceptions, glass unit masonry shall NOT be used in fire walls, party walls, fire barriers, fire partitions, smoke barriers, or for _________.

Load bearing construction

  1. Walls, partitions, and floor/ceiling assemblies between adjacent dwelling units and sleeping units shall have a sound transmission class of no less than:

50

  1. A restaurant that seats 65 patrons is in what use group?

A2

  1. Footings for masonry chimneys and fireplaces and their chimneys shall be constructed of concrete or solid masonry and not less than 12 inches thick and must extend at least how many inches beyond the face of the fireplace or foundation walls on all sides?

6 inch

  1. An issued permit will be deemed invalid if the work authorized does not commence within how many months?

6

  1. The maximum spacing of collar ties shall be ______ on center.

4 feet

  1. Joist framing on a wood floor from opposite sides on a bearing support shall overlap a minimum of how many inches

3

  1. In a single family home where attic access is required the rough opening shall be a minimum of:

22 x 30 inches

  1. At an abatement project, where should the lunchroom be located?

As far away as possible

  1. Masonry chimney cleanout openings shall be provided within ___ inches of the base of each flue.

6

  1. The edge, or face of each piece, package, or container of foam plastic insulation shall bear the label of:

An approved agency

  1. A boiler room that is over 500sf and uses 400,000 or more BTUs requires what?

2 exit doors

  1. Buildings or structures containing hazards that are classified in one or more of H-1, H-2, H-3, and H-4 use groups are required to conform to the code requirements for each of the occupancies so classified and are called:

Multiple hazards

  1. A Dormitory is in use group:

R 2

  1. What strong backed structural element is run at right angles to studs and joins them to make a solid member in concrete form work framing?

waller

  1. Metal flashing should be corrosion resistant and have a minimum thickness of ____.

.019

  1. In a commercial building what is the minimum amount and type of nails with which wood collar ties must be face nailed to rafters?

3 10d common

  1. The strength of concrete foundation is measured in:

Pounds per square inch in compression

  1. Which of these is NOT required on a Certificate of Occupancy?

The assessed value of the structure

  1. What is the minimum slope for asphalt shingles?

2:12

Study Notes

Building Code Requirements

  • Walls separating sleeping units in the same building must comply with specific provisions.

Building Elements

  • Basement walls, exterior walls, floor, roof, and other elements that enclose conditioned space or provide a boundary between conditioned space and exempt or unconditioned space are defined as building thermal envelope.

Door Requirements

  • Doors, when fully opened, must not reduce the required width by more than 3 inches.

Masonry and Fire Walls

  • Glass unit masonry must not be used in fire walls, party walls, fire barriers, fire partitions, smoke barriers, or for exterior walls.

Sound Transmission

  • Walls, partitions, and floor/ceiling assemblies between adjacent dwelling units and sleeping units must have a sound transmission class of no less than 50.

Use Groups

  • A restaurant that seats 65 patrons is in use group A-2.
  • A Dormitory is in use group R-2.
  • Buildings containing hazards classified in H-1, H-2, H-3, and H-4 use groups must conform to code requirements for each occupancy.

Footings and Foundations

  • Footings for masonry chimneys and fireplaces must be constructed of concrete or solid masonry, at least 12 inches thick, and extend at least 4 inches beyond the face of the fireplace or foundation walls on all sides.

Permits and Inspections

  • An issued permit will be deemed invalid if the work authorized does not commence within 6 months.

Framing and Roofing

  • The maximum spacing of collar ties is 48 inches on center.
  • Joist framing on a wood floor from opposite sides on a bearing support must overlap a minimum of 3 inches.
  • The minimum spacing of rafters is 24 inches on center.
  • Wood collar ties must be face nailed to rafters with at least 3-10d nails.

Chimneys and Ventilation

  • Masonry chimney cleanout openings must be provided within 6 inches of the base of each flue.

Insulation and Labeling

  • The edge, or face of each piece, package, or container of foam plastic insulation must bear the label of the manufacturer.

Boiler Rooms

  • A boiler room that is over 500sf and uses 400,000 or more BTUs requires a 2-hour fire-resistant rating.

Abatement Projects

  • At an abatement project, the lunchroom should be located outside the work area.

Concrete and Strength

  • The strength of concrete foundation is measured in pounds per square inch (psi).

Certificates of Occupancy

  • The type of construction is not required on a Certificate of Occupancy.

Roofing Materials

  • The minimum slope for asphalt shingles is 4:12.

Formwork and Framing

  • A strong backed structural element run at right angles to studs and joins them to make a solid member in concrete form work framing is a bond beam.

Flashing and Corrosion

  • Metal flashing must be corrosion resistant and have a minimum thickness of 0.019 inches.

Test your knowledge on the sound insulation requirements for walls that separate sleeping units in the same building. Learn about the provisions that must be met to ensure adequate sound insulation. Get ready to ace this quiz!

Make Your Own Quizzes and Flashcards

Convert your notes into interactive study material.

Get started for free

More Quizzes Like This

State Building Codes Overview
8 questions
Building Codes and Roof Functions
30 questions
Building Codes in the United States and Canada
8 questions
Use Quizgecko on...
Browser
Browser