What is the current status of the building for Electrical Interlocking (EI) and Interlocking Panel System (IPS)?
What is the current status of the building for Electrical Interlocking (EI) and Interlocking Panel System (IPS)?
- Completed
- Not Applicable
- Partially Completed
- Under Construction (correct)
Will the railway use an existing room for Electrical Interlocking (EI) or a new room?
Will the railway use an existing room for Electrical Interlocking (EI) or a new room?
- Existing Room
- New Room (correct)
- Both
- None of the above
On which floor is the Electrical Interlocking (EI) room planned?
On which floor is the Electrical Interlocking (EI) room planned?
- Ground Floor
- Third Floor
- Second Floor
- First Floor (correct)
Is the electrical work inside the Electrical Interlocking (EI) room, such as installing lights, switchboards, exhaust fans, and sealing fans, completed?
Is the electrical work inside the Electrical Interlocking (EI) room, such as installing lights, switchboards, exhaust fans, and sealing fans, completed?
What is the current status of the Relay Room in terms of completion?
What is the current status of the Relay Room in terms of completion?
What is the employee code of the person who conducted the site survey?
What is the employee code of the person who conducted the site survey?
What is the name of the station being surveyed?
What is the name of the station being surveyed?
Which zone does the station VINDHYACHAL belong to?
Which zone does the station VINDHYACHAL belong to?
What is the availability of storage space for equipment at the site?
What is the availability of storage space for equipment at the site?
Who is the contact person from the railway side?
Who is the contact person from the railway side?
What type of labor is available at the site for unloading?
What type of labor is available at the site for unloading?
What is the mobile number of the contractor's contact person?
What is the mobile number of the contractor's contact person?
Are the SM room and Relay room in the same building?
Are the SM room and Relay room in the same building?
What type of installation is being discussed?
What type of installation is being discussed?
What is the status of the FTOT / CT rack erection?
What is the status of the FTOT / CT rack erection?
What is the status of the 110V DC supply extension from Central to Goomty?
What is the status of the 110V DC supply extension from Central to Goomty?
What is the current status of the outdoor trenching and cable laying work?
What is the current status of the outdoor trenching and cable laying work?
What is the status of the signal foundation works?
What is the status of the signal foundation works?
What is the estimated time to complete the outdoor works?
What is the estimated time to complete the outdoor works?
Where is the 110V DC supply extended to?
Where is the 110V DC supply extended to?
Which of the following is mentioned as a concern with the outdoor works?
Which of the following is mentioned as a concern with the outdoor works?
What is the proposed number of earth pits required according to the plan?
What is the proposed number of earth pits required according to the plan?
What type of earthing arrangement is mentioned in the document?
What type of earthing arrangement is mentioned in the document?
Which cables' layout is still undecided between the Relay Room and SM Room?
Which cables' layout is still undecided between the Relay Room and SM Room?
What additional information regarding the building is specified in the document?
What additional information regarding the building is specified in the document?
What is mentioned about the photos related to the site in the document?
What is mentioned about the photos related to the site in the document?
What is the minimum height requirement for the Relay room as stated?
What is the minimum height requirement for the Relay room as stated?
Which of the following measurements is incorrect for the Relay room's height?
Which of the following measurements is incorrect for the Relay room's height?
What type of diagram must be drawn for the Relay room?
What type of diagram must be drawn for the Relay room?
What is required alongside the diagram for the Lightning arrester?
What is required alongside the diagram for the Lightning arrester?
How many Lightning arresters are required based on the information provided?
How many Lightning arresters are required based on the information provided?
What is essential to note about obstructions in the Relay room's height measurement?
What is essential to note about obstructions in the Relay room's height measurement?
Which rooms need to be included in the line diagram of floor plans?
Which rooms need to be included in the line diagram of floor plans?
What additional structural feature must be measured alongside room dimensions?
What additional structural feature must be measured alongside room dimensions?
Flashcards
Building Status for EI & IPS
Building Status for EI & IPS
Refers to whether the building is under construction or completed.
Relay Room Usage
Relay Room Usage
Determines if the railway will utilize an existing relay room or a new one.
Panel Room Status
Panel Room Status
Status of the SM room regarding whether it is a new or existing room.
First Floor EI Room
First Floor EI Room
Signup and view all the flashcards
Electrical Work Completion
Electrical Work Completion
Signup and view all the flashcards
Front Side Viewing
Front Side Viewing
Signup and view all the flashcards
FTOT/CT Rack Status
FTOT/CT Rack Status
Signup and view all the flashcards
Distributed Installation
Distributed Installation
Signup and view all the flashcards
110V DC Supply
110V DC Supply
Signup and view all the flashcards
Individual IPS
Individual IPS
Signup and view all the flashcards
Outdoor Works Status
Outdoor Works Status
Signup and view all the flashcards
Pending Trenching Work
Pending Trenching Work
Signup and view all the flashcards
Outdoor Contractor Details
Outdoor Contractor Details
Signup and view all the flashcards
Earthing arrangements
Earthing arrangements
Signup and view all the flashcards
Ring Earth
Ring Earth
Signup and view all the flashcards
Earth pits
Earth pits
Signup and view all the flashcards
OFC and Power cables
OFC and Power cables
Signup and view all the flashcards
Lightning arrester
Lightning arrester
Signup and view all the flashcards
Station Name
Station Name
Signup and view all the flashcards
Station Code
Station Code
Signup and view all the flashcards
Division Name
Division Name
Signup and view all the flashcards
Zone Name
Zone Name
Signup and view all the flashcards
Contact Person (Railways)
Contact Person (Railways)
Signup and view all the flashcards
Labour Availability
Labour Availability
Signup and view all the flashcards
Storage Space
Storage Space
Signup and view all the flashcards
Nearby Stations
Nearby Stations
Signup and view all the flashcards
Room Dimension Measurement
Room Dimension Measurement
Signup and view all the flashcards
Line Diagram
Line Diagram
Signup and view all the flashcards
Relay Room
Relay Room
Signup and view all the flashcards
Relay Room Height
Relay Room Height
Signup and view all the flashcards
Obstructions in Relay Room
Obstructions in Relay Room
Signup and view all the flashcards
Distance Measurement
Distance Measurement
Signup and view all the flashcards
Total Building Plan
Total Building Plan
Signup and view all the flashcards
Study Notes
Site Survey Report for MEI634
- Employee Code: 912194
- Employee Name: MANEESH KUMAR SONI
- Designation: SERVICE ENGINEER
- Date of Survey: 02/01/2025
- Station Name: VINDHYACHAL
- Station Code: BDL
- Division: PRAYAGRAJ
- Zone: NCR
Site Details
- Railway Contact Person: RAVI KUMAR (9794830059)
- Contractor Contact Person: SOUKAT ALI (8789309764)
- Storage Space: Availability not specified
- Equipment Unloading: Labour availability unknown
- Existing/Proposed Medha El Installations: None nearby
- SM Room and Relay Room: Located in the same building (Ground Floor)
- Building Status (El & IPS): Under construction
- Relay Room Use: Existing relay room not used for El, new room to be used
- SM Room Status: New room
- El Room Floor: 1st Floor
- Relay Room Completion Status: Under construction
- Electrical Work Completion: Pending
- Electricity Availability: Pending for relay room (centralized), distributed to goomtys
- Track View: Front side
- FTOT/CT Rack Erection: Not completed
- Outdoor Trenching and Cable Laying Status: Pending
- Time to Complete Outdoor Works: Unknown
- Outdoor Contractor: SOUKAT ALI (8789309764)
- Contractor Name: THAKUR INTERPRIZES
Floor Plans
- Room Dimensions: Measured accurately, including windows, pillars, doors, and ventilation
- Line Diagrams: Floor plans for Relay room, IPS room, Battery room, SM room, MT room, and total building, along with measurements, drawn and attached
- FTOT/CT Rack Placement: Located in Relay room floor plan, drawn and attached
- Lightning Arrester: 2 required
- Relay Room to IPS Distance: Both on 1st floor, within a short distance
- Relay Room Height: > 2634mm (with obstructions measured), 2634mm (CIU, Double ladder)
Other Details
- Earthing: Ring earthing possible
- Signaling Cable Distance & Soil Details: Distance from proposed earth pit locations and soil type are unknown
- Number of Earthing Pits: 12
- Redundant U/G OFC and Power Cables: Not decided
- Complete Building Measurements: Length, width, and height are needed
- Photos of Site: Available, and attached (Relay, IPS, Battery, SM, MT rooms, lightening arrester placement, and earthing locations)