Seismic Design of Reinforced Concrete Buildings: Section 404.4.6
17 Questions
0 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which seismic zone shall a structure be assigned to in accordance with the general building code?

  • Seismic zone 4 or 2 (correct)
  • Seismic zone 3 or 1
  • Seismic zone 1 or 3
  • Seismic zone 5 or 6
  • What is structural integrity in the context of reinforced concrete buildings?

  • An ability of a structure to redistribute stresses and maintain overall stability (correct)
  • The ability of a structure to resist earthquakes
  • The ability of a structure to withstand natural disasters
  • The ability of a structure to resist wind loads
  • What is required for structural systems assigned to seismic zone 4?

  • Only the requirements of the general building code
  • Only the requirements of section 418
  • Neither the requirements of section 418 nor the general building code
  • The requirements of section 418 and other applicable sections (correct)
  • Why is it essential to detail reinforcement and connections?

    <p>To effectively tie the structure together and improve overall structural integrity</p> Signup and view all the answers

    What is the purpose of detailing reinforcement and connections?

    <p>To redistribute stresses and maintain overall stability</p> Signup and view all the answers

    What is the primary intention behind designing structures according to the provisions of Section 418?

    <p>To resist earthquake motions through ductile inelastic response of selected members</p> Signup and view all the answers

    What is the minimum clear span requirement for flexural members of special moment frames in Zone 4?

    <p>4x effective depth</p> Signup and view all the answers

    Which of the following is NOT a requirement for flexural members of special moment frames in Zone 4?

    <p>Effective depth ≤ 4x clear span</p> Signup and view all the answers

    What type of structural systems are designated as part of the seismic-force-resisting system?

    <p>Structural systems, including diaphragms, moment frames, structural walls, and foundations</p> Signup and view all the answers

    Which section of the code applies to the design of nonprestressed and prestressed concrete structures assigned to seismic zone 4?

    <p>Section 418</p> Signup and view all the answers

    What is the purpose of anchors in seismic design?

    <p>Not specified in Section 418</p> Signup and view all the answers

    What is the minimum reinforcement ratio for longitudinal and transverse axes in special concrete structural walls?

    <p>0.0025</p> Signup and view all the answers

    What is the minimum dimension of the column parallel to the reinforcement when it extends through a joint?

    <p>20 db</p> Signup and view all the answers

    Which of the following is a requirement for shear walls with in-plane Vu ≤ φVc?

    <p>Two curtains of reinforcements</p> Signup and view all the answers

    What is the maximum Vu value for walls less than 250 mm thick?

    <p>0.083 Acv√f’c</p> Signup and view all the answers

    Where must longitudinal beam reinforcements be terminated in Zone 4 and Zone 2?

    <p>Into a column core</p> Signup and view all the answers

    What is the purpose of extending longitudinal beam reinforcements into the far face of the confined column core?

    <p>To provide anchorage in both tension and compression</p> Signup and view all the answers