🎧 New: AI-Generated Podcasts Turn your study notes into engaging audio conversations. Learn more

PAES 401:2001 Agricultural Structures for Swine Housing Quiz
28 Questions
3 Views

PAES 401:2001 Agricultural Structures for Swine Housing Quiz

Created by
@VerifiableSitar

Podcast Beta

Play an AI-generated podcast conversation about this lesson

Questions and Answers

Which publication specifies the minimum requirements for swine housing?

  • Swine Barn Construction and Services Plan
  • The Philippines Recommends for Pork Production
  • D-1 Swine Housing and Equipment Plan (correct)
  • Squibb Swine Farming Manual
  • Which publication focuses on pig husbandry in warm climates?

  • Natural Ventilation for Pig Housing
  • Training Manual for Swine Production
  • Swine Care Handbook
  • Pig Husbandry for Warm Climates (correct)
  • Which manual is part of the MWPS series and focuses on swine housing and equipment?

  • The Philippines Recommends for Pork Production
  • D-2 PHILIPPINE AGRICULTURAL ENGINEERING STANDARD PAES 401:2001
  • Swine Barn Construction and Services Plan (correct)
  • Swine Care Handbook
  • Which publication provides recommended humane standards for raising livestock and poultry?

    <p>The Philippines Recommends for Pork Production</p> Signup and view all the answers

    Which standard specifies the minimum requirements for agricultural structures related to swine production?

    <p>D-2 PHILIPPINE AGRICULTURAL ENGINEERING STANDARD PAES 401:2001</p> Signup and view all the answers

    What is the recommended top width for a concrete slat with a 2.40 m span?

    <p>152 mm</p> Signup and view all the answers

    Which reinforcing bar size is recommended for a concrete slat with a 3.0 m span?

    <p>No. 5 (14 mm)</p> Signup and view all the answers

    What is the recommended depth for a concrete slat with a 1.80 m span and a top width of 152 mm?

    <p>152 mm</p> Signup and view all the answers

    What is the recommended reinforcing bar size for a concrete slat with a 1.20 m span?

    <p>No. 3 (10 mm)</p> Signup and view all the answers

    What is the recommended spacing for supporting joists under flattened expanded metal flooring?

    <p>300 mm</p> Signup and view all the answers

    What is the recommended wire spacing for welded wire flooring?

    <p>12.5 mm</p> Signup and view all the answers

    What was the project that initiated the formulation of this national standard?

    <p>Enhancing the Implementation of the AFMA</p> Signup and view all the answers

    What is the purpose of the word 'shall' as used in this standard?

    <p>To indicate requirements that must be followed</p> Signup and view all the answers

    What is the purpose of the word 'should' as used in this standard?

    <p>To indicate the preferred course of action without excluding others</p> Signup and view all the answers

    Which of the following documents was referenced in the formulation of this standard?

    <p>All of the above</p> Signup and view all the answers

    What is the purpose of the standard PAES 401:2001?

    <p>To specify the general requirements for swine housing</p> Signup and view all the answers

    Which of the following is NOT mentioned as a reference used in the formulation of this standard?

    <p>PNS 01-4:1998 (ISO/IEC Directives Part 3:1997 – Rules for the Structure and Drafting of International Standards)</p> Signup and view all the answers

    What is the formula for calculating the number of bulbs required per square meter for incandescent lamps?

    <p>$1.052 \times (\text{No. of Sows} \times \text{Culling Rate} \times \text{Occupancy Period} \times 1.1)$</p> Signup and view all the answers

    What is the lighting intensity requirement in lux for fluorescent lamps?

    <p>150</p> Signup and view all the answers

    How many bulbs are required per square meter for a 150W incandescent lamp?

    <p>0.316</p> Signup and view all the answers

    In the context of lighting requirements, what wattage of incandescent lamp requires 0.063 bulbs per square meter?

    <p>150W</p> Signup and view all the answers

    For a 25W fluorescent lamp, how many bulbs are needed per square meter?

    <p>0.682</p> Signup and view all the answers

    In the one-unit system, where do the pigs remain from birth until slaughter?

    <p>In the same building</p> Signup and view all the answers

    Which of the following systems involves moving the pigs to a separate growing-finishing house after weaning?

    <p>Two-unit system</p> Signup and view all the answers

    In the four-unit system, what is the order in which the pigs move through the different housing units?

    <p>Farrowing house -&gt; Nursery house -&gt; Growing house -&gt; Finishing house</p> Signup and view all the answers

    Which system involves the fewest number of housing unit transitions for the pigs?

    <p>One-unit system</p> Signup and view all the answers

    What is the maximum number of separate housing units that pigs may be moved through according to the systems described?

    <p>4 units</p> Signup and view all the answers

    Based on the information given, in which system(s) do the sows and piglets remain together after farrowing until weaning?

    <p>One-unit, two-unit, and three-unit systems</p> Signup and view all the answers

    Study Notes

    Housing Systems for Swine Production

    • The Philippines has a recommended standard for swine housing, known as PAES 401:2001, which specifies minimum requirements for swine housing.
    • There are four types of housing systems: one-unit, two-unit, three-unit, and four-unit systems.

    One-Unit System

    • Sows and piglets remain in the same building from farrowing until they reach the desired weight for slaughtering.

    Two-Unit System

    • Sows and piglets remain in the farrowing house until weaning, then weanlings are transferred to a growing-finishing house.

    Three-Unit System

    • Sows and piglets remain in the farrowing house until weaning, then weanlings are moved to a nursery house, and finally to a growing-finishing unit.

    Four-Unit System

    • Sows and piglets remain in the farrowing house until weaning, then weanlings are moved to a nursery house, then to a growing house, and finally to a finishing house until they are ready for slaughter.

    Space Requirements

    • Minimum space requirements for swine are specified in Table 1 of the PAES 401:2001 standard.

    Concrete Slat Specifications

    • Recommended specifications for concrete slat design are shown in Table 3 and Figure 7.
    • Span, slat dimensions, and reinforcing bar requirements are specified.

    Flooring Requirements

    • For swine under 20 kg, flattened expanded metal (20 mm, 9 –11 gauge) shall be used.
    • Welded wire flooring shall be made of 5.3 mm (5 gauge) wire spaced at 12.5 mm, 15 mm or 18 mm.
    • Plastic flooring shall be coated with a rough surface.

    Lighting Requirements

    • Lighting intensity requirements are specified in Annex C of the PAES 401:2001 standard.

    Sample Production Calculations

    • Sample calculations for a 24-sow level fattener production are shown in Annex B of the PAES 401:2001 standard.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on the Philippine Agricultural Engineering Standard PAES 401:2001 for Agricultural Structures – Housing for Swine Production. Learn about the standards and regulations set for swine housing in the Philippines.

    Use Quizgecko on...
    Browser
    Browser