What is the primary function of the dedicated member of the 2 in / 2 out pair?
What is the primary function of the dedicated member of the 2 in / 2 out pair?
- To communicate with Command
- To operate the pumper
- To track interior personnel (correct)
- To assist with rescue efforts
When is the 2 in / 2 out standard met?
When is the 2 in / 2 out standard met?
- When the second arriving fire company is positioned on scene or in Level 1 staging (correct)
- When the Incident Commander assumes command
- When the 2 in / 2 out team members are in place
- When the first arriving fire company arrives on scene
Who is responsible for managing the accountability of the 2 in / 2 out team members?
Who is responsible for managing the accountability of the 2 in / 2 out team members?
- The Incident Commander (correct)
- The Engineer
- The AHQ
- The 2 in / 2 out team members
What is the purpose of the 2 in / 2 out procedure?
What is the purpose of the 2 in / 2 out procedure?
What is the requirement for the 2 in / 2 out team members in a Mayday situation?
What is the requirement for the 2 in / 2 out team members in a Mayday situation?
What is the primary objective of the 2 in / 2 out procedure?
What is the primary objective of the 2 in / 2 out procedure?
According to OSHA, when is the atmosphere assumed to be IDLH?
According to OSHA, when is the atmosphere assumed to be IDLH?
When is the 2 in / 2 out procedure not required?
When is the 2 in / 2 out procedure not required?
What is the reason for establishing the 2 in / 2 out procedure?
What is the reason for establishing the 2 in / 2 out procedure?
What is the acceptable reason for not meeting the 2 in / 2 out standard?
What is the acceptable reason for not meeting the 2 in / 2 out standard?
During the initial deployment of the first in company, what is the only necessary radio communication with regards to 2 in / 2 out?
During the initial deployment of the first in company, what is the only necessary radio communication with regards to 2 in / 2 out?
Study Notes
2 In / 2 Out Procedure
- The purpose of the 2 in / 2 out procedure is to meet the OSHA standard (29 CFR 1910.134(g)(4)) and ensure the safety of firefighters during interior structural fires.
- The objective is to have fully equipped firefighters in position to react in case of a Mayday situation.
OSHA Standard
- OSHA states that fire fighters begin the interior attack on an interior structural fire, the atmosphere is assumed to be Immediately Dangerous to Life or Health (IDLH) and the 2 in / 2 out procedure applies.
Exceptions to the 2 in / 2 out Requirement
- Reported or suspected life hazard where immediate action could prevent the loss of life.
- Fire is in an incipient stage (defined as a fire which can be controlled or extinguished by portable fire extinguishers, Class II standpipe or small hose systems without the need for protective clothing or breathing apparatus).
Operational 2 in / 2 out
- A temporary two-person tactical reserve assigned at the outset of an incident to allow teams to enter an IDLH, or potential IDLH atmosphere.
- One primary member of the 2 in / 2 out pair must be solely dedicated to tracking interior personnel.
- The second member of the 2 in / 2 out team may be engaged in other activities within the hazard zone.
Implementation of 2 in / 2 out for a Four-Person Crew
- The plug person assumes the primary 2 in / 2 out position and the engineer assumes the secondary 2 in / 2 out position.
- Rescue efforts should be initiated as a team (2 members) and well communicated prior to action.
- Mayday response should be managed with the Risk Management Plan by the incident commander and acted upon based on the capabilities of the 2 in / 2 out team.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Description
This procedure outlines the considerations for meeting the 2 in / 2 out requirement based on OSHA 29 CFR 1910.134(g)(4) for the Phoenix Regional Dispatch System. It aims to meet OSHA standards while catering to tactical needs in hazard zones.