Podcast
Questions and Answers
What is the purpose of the 'Wise Shutter' feature?
What is the purpose of the 'Wise Shutter' feature?
- To provide collimation without X-ray (correct)
- To enhance image quality
- To enable pulsed fluoroscopy
- To reduce motion compensation
Which technology is used for adaptive noise reduction in the Azurion 5M20?
Which technology is used for adaptive noise reduction in the Azurion 5M20?
- Wise Variable
- DoseWise
- SPIRIT Adaptive Noise reduction (correct)
- CARE Vision
What is the minimum dose rate that can be achieved with WiseChoice?
What is the minimum dose rate that can be achieved with WiseChoice?
- 10R/min
- 20R/min
- 15R/min
- 5R/min (correct)
What is the purpose of the 'CARE Position' feature?
What is the purpose of the 'CARE Position' feature?
Which of the following machines has a 'D-Monitor' feature?
Which of the following machines has a 'D-Monitor' feature?
What is the purpose of the 'SpectraBeam' feature?
What is the purpose of the 'SpectraBeam' feature?
Which technology is used for harmonic imaging in the Azurion 5M20?
Which technology is used for harmonic imaging in the Azurion 5M20?
What is the purpose of the 'Wise Mem' feature?
What is the purpose of the 'Wise Mem' feature?
What is the resolution of the XperCT ICS High Res?
What is the resolution of the XperCT ICS High Res?
What is the advantage of a smaller pixel size in clinical applications?
What is the advantage of a smaller pixel size in clinical applications?
Which feature of Azurion 5M20 allows for real-time 3D navigation during procedures?
Which feature of Azurion 5M20 allows for real-time 3D navigation during procedures?
What is the function of the CAAA feature in Azurion 5M20?
What is the function of the CAAA feature in Azurion 5M20?
What is the purpose of a copper spectral filter in X-ray imaging?
What is the purpose of a copper spectral filter in X-ray imaging?
What is the purpose of the 'Zero Dose Positioning' feature in Azurion 5M20?
What is the purpose of the 'Zero Dose Positioning' feature in Azurion 5M20?
What is the benefit of the 'DoseWise' technology developed by Philips?
What is the benefit of the 'DoseWise' technology developed by Philips?
What is the term for the amount of information contained in an image, affecting the image's clarity?
What is the term for the amount of information contained in an image, affecting the image's clarity?
What is the maximum reconstruction matrix of the XperCT ICS High Res?
What is the maximum reconstruction matrix of the XperCT ICS High Res?
What is the 'BLUE' technology developed by Philips for angiography?
What is the 'BLUE' technology developed by Philips for angiography?
What is the function of the 'MAR' feature in Azurion 5M20?
What is the function of the 'MAR' feature in Azurion 5M20?
What is the benefit of the 'Instant Parallel Working' feature in Azurion 5M20?
What is the benefit of the 'Instant Parallel Working' feature in Azurion 5M20?
What determines the ability of a detector to distinguish between different tissues?
What determines the ability of a detector to distinguish between different tissues?
What is the benefit of the 'SPIRIT+XRES' image processing technology?
What is the benefit of the 'SPIRIT+XRES' image processing technology?
What is the purpose of the 'ProcedureCards' feature in Azurion 5M20?
What is the purpose of the 'ProcedureCards' feature in Azurion 5M20?
What is the benefit of the 'Connect OS' feature in Azurion 5M20?
What is the benefit of the 'Connect OS' feature in Azurion 5M20?
What is the purpose of the 'LIH' (Live Image Guidance) feature in fluoroscopy?
What is the purpose of the 'LIH' (Live Image Guidance) feature in fluoroscopy?
What is the advantage of a larger matrix size in angiography?
What is the advantage of a larger matrix size in angiography?
What is the purpose of the 'Checklists & Protocols' feature in Azurion 5M20?
What is the purpose of the 'Checklists & Protocols' feature in Azurion 5M20?
What does the 'zero position' feature in fluoroscopy refer to?
What does the 'zero position' feature in fluoroscopy refer to?
Study Notes
Philips 27-inch Display
- Equivalent to 2 x 19-inch displays with a larger visual field
- Currently the most advanced display device
Parallel Processing
- Enables simultaneous processing and browsing of current and other patients' systems without affecting surgical procedures
- Supports instant parallel working with pure, suitable for different patients
System Design
- Single workstation with a large flat panel and a touch screen module
- Equipped with a liquid crystal touch screen and a control module
- Supports automatic image processing and browsing
Imaging Technology
- Supports 3D image reconstruction, virtual stenting, and catheter tip shape simulation
- Enables single-stop 3D imaging with a large flat panel
- Supports multi-planar reconstruction (MPR) and CT-like image fusion
Dose Control Methods
- Supports low-dose technology, DoseWise, with a reduction of up to 50%
- Enables dose control with Wise Variable, Wise Shutter, and Wise APC/zero position
- Supports SpectraBeam and has a dose display function, Wise View
- Enables dose reporting with Wise Report
System Comparison
- Azurion 5M20, Artis Icono, Artis zee III, Allia IGS 7, Artis Q ceiling, and NeuAngio 43C are compared in terms of their system specifications, dose control methods, and imaging technology.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
This quiz compares features of different medical display systems, including Philips' 27-inch monitor, and highlights their advanced capabilities in parallel processing and image display.