How often should the construction supervisor inspect work for code compliance?
How often should the construction supervisor inspect work for code compliance?
What must be posted at the construction site to ensure transparency?
What must be posted at the construction site to ensure transparency?
What is required to maintain compliance with OSHA regulations on-site?
What is required to maintain compliance with OSHA regulations on-site?
How should construction debris be properly managed during a project?
How should construction debris be properly managed during a project?
Signup and view all the answers
When is an unrestricted construction supervisor required to hire a design professional?
When is an unrestricted construction supervisor required to hire a design professional?
Signup and view all the answers
What is the requirement for the disposal of hazardous materials?
What is the requirement for the disposal of hazardous materials?
Signup and view all the answers
When is it necessary to notify the utility company during construction?
When is it necessary to notify the utility company during construction?
Signup and view all the answers
What should be done immediately when a safety issue is identified at a construction site?
What should be done immediately when a safety issue is identified at a construction site?
Signup and view all the answers
What is the minimum safety requirement in terms of construction site accessibility?
What is the minimum safety requirement in terms of construction site accessibility?
Signup and view all the answers
Which action is required when a construction site is scheduled for inspection?
Which action is required when a construction site is scheduled for inspection?
Signup and view all the answers
What is the minimum notification period for abutters prior to excavation in Massachusetts?
What is the minimum notification period for abutters prior to excavation in Massachusetts?
Signup and view all the answers
What must be done if an adjacent property is damaged during construction?
What must be done if an adjacent property is damaged during construction?
Signup and view all the answers
What is required before demolishing an existing structure?
What is required before demolishing an existing structure?
Signup and view all the answers
Which of the following is required during the hiring of subcontractors?
Which of the following is required during the hiring of subcontractors?
Signup and view all the answers
What must be done if unexpected conditions arise during foundation excavation?
What must be done if unexpected conditions arise during foundation excavation?
Signup and view all the answers
What is the main purpose of documentation during construction projects?
What is the main purpose of documentation during construction projects?
Signup and view all the answers
How often should inspections be scheduled during a construction project?
How often should inspections be scheduled during a construction project?
Signup and view all the answers
What is the process for handling hazardous materials during construction?
What is the process for handling hazardous materials during construction?
Signup and view all the answers
What should be included in a building permit renewal application?
What should be included in a building permit renewal application?
Signup and view all the answers
What is a potential consequence of failing to comply with construction regulations?
What is a potential consequence of failing to comply with construction regulations?
Signup and view all the answers
What must be reported to OSHA when dealing with hazardous materials on a construction site?
What must be reported to OSHA when dealing with hazardous materials on a construction site?
Signup and view all the answers
What occurs if work hasn't commenced on a building project within six months?
What occurs if work hasn't commenced on a building project within six months?
Signup and view all the answers
Which entity is responsible for approving building plans in some regions?
Which entity is responsible for approving building plans in some regions?
Signup and view all the answers
What is the penalty for violating construction regulations in Massachusetts?
What is the penalty for violating construction regulations in Massachusetts?
Signup and view all the answers
When can construction commence according to the building code?
When can construction commence according to the building code?
Signup and view all the answers
How often should inspections take place during a construction project?
How often should inspections take place during a construction project?
Signup and view all the answers
What is a common requirement before excavation work can begin?
What is a common requirement before excavation work can begin?
Signup and view all the answers
If unsafe conditions are detected, what action should be taken according to the building code?
If unsafe conditions are detected, what action should be taken according to the building code?
Signup and view all the answers
What must be provided by the contractor regarding subcontractors?
What must be provided by the contractor regarding subcontractors?
Signup and view all the answers
What documentation must be available at a construction site during inspections?
What documentation must be available at a construction site during inspections?
Signup and view all the answers
What should be done immediately if water infiltration occurs during construction?
What should be done immediately if water infiltration occurs during construction?
Signup and view all the answers
What is the maximum slope allowed for temporary construction ramps?
What is the maximum slope allowed for temporary construction ramps?
Signup and view all the answers
What action must be taken when working near power lines?
What action must be taken when working near power lines?
Signup and view all the answers
What is a primary requirement for a construction supervisor during the construction process?
What is a primary requirement for a construction supervisor during the construction process?
Signup and view all the answers
What should a contractor do if a permit is about to expire?
What should a contractor do if a permit is about to expire?
Signup and view all the answers
Which of the following is necessary for compliance enforcement?
Which of the following is necessary for compliance enforcement?
Signup and view all the answers
What documentation is necessary prior to starting construction?
What documentation is necessary prior to starting construction?
Signup and view all the answers
What should be prioritized during the inspection scheduling process?
What should be prioritized during the inspection scheduling process?
Signup and view all the answers
How should hazardous materials be handled on a construction site?
How should hazardous materials be handled on a construction site?
Signup and view all the answers
What requirement must be observed when documenting changes in construction plans?
What requirement must be observed when documenting changes in construction plans?
Signup and view all the answers
Study Notes
Massachusetts CSL Exam Practice Questions
-
Question 1: The maximum riser height for residential stairs is 8 1/4 inches (R311.7.5).
-
Question 2: ASTM D3201 governs fire retardant-treated wood in Massachusetts.
-
Question 3: First aid kits on construction sites must be inspected weekly.
-
Question 4: The maximum extension length for a platform less than 10 feet long is 12 inches.
-
Question 5: The U-factor for steel-framed ceilings in unconditioned spaces in Massachusetts is 0.026.
-
Question 6: The required minimum thickness for a residential concrete slab is 3 1/2 inches.
-
Question 7: Masonry foundation walls must extend 4 inches above finished grade without veneer.
-
Question 8: The flame spread index limit for concealed insulation is 25.
-
Question 9: The minimum ventilation requirement for underfloor crawl spaces is 1 square foot per 150 square feet.
-
Question 10: The minimum requirement for parking spaces for a lot with 15 spaces is 1 accessible space, per AAB.
-
Question 11: The allowable slope for low-slope roofs is 2:12.
-
Question 12: The flame spread index requirement for fire-retardant treated wood is 25.
-
Question 13: The maximum length of a hallway in a sprinklered Group B building is 300 feet.
-
Question 14: The required guardrail height for patios more than 30 inches above grade is 42 inches.
-
Question 15: The maximum air leakage for windows under the IRC is 0.30 cfm per square foot.
-
Question 16: The correct moisture content for interior fire-retardant-treated wood under ASTM D3201 is 28%.
-
Question 17: The minimum distance between a combustion air intake opening and a property line is 10 feet.
-
Question 18: The minimum bearing length of wood joists on masonry is 2 inches.
-
Question 19: The maximum distance for control joints in a concrete basement floor is 30 feet.
-
Question 20: Full compliance accessibility is required for new public buildings, including houses of worship.
-
Question 1 (Page 6): Minimum width for egress doors in residential construction is 36 inches.
-
Question 2 (Page 6): Maximum height for a stairway rise in residential construction is 7 3/4 inches.
-
Question 3 (Page 6): Fire extinguishers must be placed every 75 feet on a construction site.
-
Question 4 (Page 7): Minimum headroom clearance for stairways is 6'8".
-
Question 5 (Page 7): The maximum height for a structure without a sprinkler system in Type V construction is 3 stories.
-
Question 6 (Page 7): The minimum compressive strength for concrete used in footings is 2500 psi.
-
Question 7 (Page 7): A fire-resistant-rated wall between a garage and a dwelling is required when the garage is attached.
-
Question 8 (Page 7): Accessible parking spaces required for a parking lot with 100 spaces is 4.
-
Question 9 (Page 7): Minimum height for handrails in stairways is 32 inches.
-
Question 10 (Page 8): Anchor bolts should be spaced 4 feet apart in a sill plate.
-
Question 11 (Page 8): The required slope for drainage away from a building foundation is 2%.
-
Question 12 (Page 8): The maximum flame spread index for wall coverings in a means of egress is 75.
-
Question 13 (Page 8): The maximum span for #4 rebar in concrete without additional support is 5 feet.
-
Question 14 (Page 8): The maximum height for a retaining wall before engineer design is needed is 5 feet.
-
Question 15 (Page 9): The minimum thickness for exterior walls in residential construction is 4 inches.
-
Question 16 (Page 9): Allowable height for smoke detectors from the floor to the ceiling is 10 feet.
-
Question 17 (Page 9): An assembly room with 500 people capacity requires 2 exits.
-
Question 18 (Page 9): The maximum number of risers allowed in a single flight of stairs is 15.
-
Question 19 (Page 9): The maximum allowable U-factor for residential windows in Massachusetts is .30.
-
Question 20 (Page 9): The minimum air exchange rate for mechanical ventilation systems in homes is 0.25 ACH.
-
Question 1 (Page 11): Minimum R-value for attic insulation in new Massachusetts residential construction is R-30.
-
Question 2 (Page 11): Minimum R-value for wood-framed walls in new construction in Massachusetts is R-15.
-
Question 3 (Page 11): Maximum U-factor for windows in new construction in Massachusetts is .30.
-
Question 4 (Page 11): Required air leakage rate for a home to pass the blower door test in Massachusetts is 5 ACH at 50 Pascals.
-
Question 5 (Page 11): Minimum R-value for floors over unconditioned spaces in Massachusetts is R-25.
-
Question 6 (Page 12): Minimum R-value for basement walls in unconditioned spaces in Massachusetts is R-15.
-
Question 7 (Page 12): Required insulation level for ducts in unconditioned spaces in Massachusetts is R-8.
-
Question 8 (Page 12): Minimum R-value for crawl space walls in Massachusetts is R-13.
-
Question 9 (Page 12): Maximum solar heat gain coefficient (SHGC) for windows in Massachusetts is .35.
-
Question 10 (Page 12): Maximum U-factor for skylights in Massachusetts is .50.
-
Question 11 (Page 12): Minimum energy efficiency for furnaces in two-zone HVAC systems in Massachusetts is 80% AFUE.
-
Question 12 (Page 13): Minimum energy factor for gas-fired water heaters in Massachusetts is 0.70.
-
Question 13 (Page 13): Type of insulation required for hot water pipes in unconditioned spaces in Massachusetts is R-3.
-
Question 14 (Page 13): The required minimum lighting efficiency for permanently installed lighting in new construction in Massachusetts is 90% high-efficacy.
-
Question 15 (Page 13): Percentage of the home's energy consumption that must come from renewable sources in order to qualify for a zero-energy ready designation in Massachusetts is 50%.
-
Question 16 (Page 13): Vapor barriers must be installed at least 3 inches from the warm-in-winter side of the insulation.
-
Question 17 (Page 14): Minimum insulation level required for slab-on-grade floors in Massachusetts is R-10 for 2 feet.
-
Question 18 (Page 14): Minimum required ventilation rate for new residential construction in Massachusetts is 0.35 ACH.
-
Question 19 (Page 14): Maximum allowable leakage for ducts in unconditioned spaces in Massachusetts is 5%.
-
Question 20 (Page 14): Amount of solar-ready zone space required on a roof for new residential construction in Massachusetts is 150 square feet.
-
Question 1 (Page 16): The primary responsibility of an unrestricted construction supervisor is supervising the construction process to ensure code compliance.
-
Question 2 (Page 16): The required action when a change to the approved building plans is made is to notify the building inspector immediately.
-
Question 3 (Page 17): The person responsible for ensuring subcontractors adhere to safety regulations on-site is the general contractor.
-
Question 4 (Page 17): If a construction site generates excessive noise during restricted hours, stop work and move to quieter tasks, and notify neighbors.
-
Question 5 (Page 17): A construction supervisor must maintain the contractor's personal license, original building permit and approved plans, and payment receipts for materials.
-
Question 6 (Page 18): If hazardous materials like asbestos are discovered, report it to OSHA and hire a licensed abatement contractor.
-
Question 7 (Page 18): A building permit must be renewed when the work hasn't commenced within six months or the project scope changes.
-
Question 8 (Page 18): Scheduling inspections at key project milestones is the responsibility of the construction supervisor.
-
Question 9 (Page 19): The maximum fine for failing to comply with Massachusetts Building Code as an unrestricted supervisor is $2,000 per violation.
-
Question 10 (Page 19): Work on a construction site can commence after securing a building permit.
-
Question 11 (Page 19): The zoning board enforces local zoning laws compliance
-
Question 12 (Page 20): Minimum notification period for abutters before excavation in Massachusetts is 10 days.
-
Question 13 (Page 20): Steps taken when an adjacent property is damaged during construction are to document the damage, notify the inspector and property owner, and halt work until resolution.
-
Question 14 (Page 20): A written agreement from neighbors is required before demolishing existing structures.
-
Question 15 (Page 21): Required action during hiring of subcontractors is verifying their licenses and insurance.
-
Question 16 (Page 21): If unexpected conditions arise during foundation excavation, adjust plans, inform the property owner, and consult a structural engineer.
-
Question 17 (Page 21): Construction supervisors should inspect work for code compliance regularly throughout the project.
-
Question 18 (Page 22): The approved building plans and permit must be posted at the construction site.
-
Question 19 (Page 22): To maintain OSHA compliance, weekly safety audits, documentation of jobsite injuries, and displaying the OSHA poster on-site are required.
-
Question 20 (Page 22): Construction debris should be disposed of in accordance with local regulations.
-
Question 21 (Page 22): Unrestricted construction supervisors must hire a design professional for every structural project and when structural modifications are made to an existing building.
-
Question 22 (Page 23): Maximum slope allowed for temporary construction ramps is 15%.
-
Question 23 (Page 23): Required action when working near power lines is to notify the utility company and maintain a safe distance.
-
Question 24 (Page 23): If water infiltration occurs during construction, stop work and address the issue immediately.
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Test your knowledge with these practice questions for the Massachusetts CSL Exam. Covering critical topics like construction standards, fire safety, and building regulations, this quiz will help you prepare effectively. Each question focuses on important codes and requirements for construction in Massachusetts.