Podcast
Questions and Answers
What is the purpose of storing the specimens in the environmental chamber?
What is the purpose of storing the specimens in the environmental chamber?
What should be checked before turning on the switches of the Haze meter?
What should be checked before turning on the switches of the Haze meter?
What is the purpose of setting the white plate for compensation at the compensation window?
What is the purpose of setting the white plate for compensation at the compensation window?
Why is it necessary to take 5 measurements of each individual specimen?
Why is it necessary to take 5 measurements of each individual specimen?
Signup and view all the answers
What is the purpose of reporting the average results with 1 digit under decimal for both Haze (%) and Light Transmittance tt (%)?
What is the purpose of reporting the average results with 1 digit under decimal for both Haze (%) and Light Transmittance tt (%)?
Signup and view all the answers
What should be done after disposing waste samples to the appropriate waste container?
What should be done after disposing waste samples to the appropriate waste container?
Signup and view all the answers
Why is it important to turn on the switches of the Haze meter after checking the D65 lamp at the back side?
Why is it important to turn on the switches of the Haze meter after checking the D65 lamp at the back side?
Signup and view all the answers
What is the purpose of compensating for all while checking initial status of Haze meter?
What is the purpose of compensating for all while checking initial status of Haze meter?
Signup and view all the answers
The specimens should be stored at 23 2C and 50 5%RH Humidity for one night.
The specimens should be stored at 23 2C and 50 5%RH Humidity for one night.
Signup and view all the answers
The Haze meter should be turned on before checking the D65 lamp at the back side.
The Haze meter should be turned on before checking the D65 lamp at the back side.
Signup and view all the answers
The measuring items include Transparency, tt, and Haze.
The measuring items include Transparency, tt, and Haze.
Signup and view all the answers
The Light Source for the Haze meter is C-Light and T&H Filter.
The Light Source for the Haze meter is C-Light and T&H Filter.
Signup and view all the answers
The Start button should be pressed without specimen to adjust the standard.
The Start button should be pressed without specimen to adjust the standard.
Signup and view all the answers
The waste samples should be disposed in any waste container available.
The waste samples should be disposed in any waste container available.
Signup and view all the answers
After completing the analysis, proper housekeeping in the area is not necessary.
After completing the analysis, proper housekeeping in the area is not necessary.
Signup and view all the answers
The purpose of setting the white plate for compensation at the compensation window is to adjust the standard without specimen.
The purpose of setting the white plate for compensation at the compensation window is to adjust the standard without specimen.
Signup and view all the answers
What is the purpose of storing the specimens in the environmental chamber?
What is the purpose of storing the specimens in the environmental chamber?
Signup and view all the answers
Why is it important to adjust the standard without specimen using the white plate for compensation at the compensation window?
Why is it important to adjust the standard without specimen using the white plate for compensation at the compensation window?
Signup and view all the answers
What should be checked before turning on the switches of the Haze meter?
What should be checked before turning on the switches of the Haze meter?
Signup and view all the answers
Why is it necessary to take 5 measurements of each individual specimen?
Why is it necessary to take 5 measurements of each individual specimen?
Signup and view all the answers
What is the purpose of reporting the average results with 1 digit under decimal for both Haze (%) and Light Transmittance tt (%)?
What is the purpose of reporting the average results with 1 digit under decimal for both Haze (%) and Light Transmittance tt (%)?
Signup and view all the answers
What is the purpose of compensating for all while checking initial status of Haze meter?
What is the purpose of compensating for all while checking initial status of Haze meter?
Signup and view all the answers
What is the purpose of setting the white plate for compensation at the compensation window before pressing the S-ADJ button?
What is the purpose of setting the white plate for compensation at the compensation window before pressing the S-ADJ button?
Signup and view all the answers