Floating Point Representation Quiz
22 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the primary use of a Venturi transmitter?

  • Pressure drop measurement
  • High flow measurement
  • Level measurement
  • Low flow measurement (correct)
  • Which statement is true regarding RTD measurements?

  • RTD typically measures flow rates
  • RTD measures temperature in ohms (correct)
  • RTD measures pressure in millivolts
  • RTD operates only in high temperature ranges
  • What type of measurement does a Rotameter primarily perform?

  • Level measurement
  • Pressure measurement
  • Temperature measurement
  • Small flow measurement (correct)
  • Which device is a protective device used in temperature measurement?

    <p>Thermo-well</p> Signup and view all the answers

    Which of the following offers a local analog pressure measurement?

    <p>Pressure Gauge</p> Signup and view all the answers

    What does a sight glass measure?

    <p>Level and contains process in glass</p> Signup and view all the answers

    How does a displacer measure level?

    <p>By taking the differential pressure as buoyancy displaces an arm</p> Signup and view all the answers

    Which device is primarily used for flow measurement?

    <p>Rotameter</p> Signup and view all the answers

    Which statement about a Venturi is correct?

    <p>It minimizes pressure loss while creating a pressure drop.</p> Signup and view all the answers

    What is a common application of a rotameter?

    <p>Flow measurement in piping systems</p> Signup and view all the answers

    What output signal do thermocouples typically produce?

    <p>Millivolts</p> Signup and view all the answers

    Why is a thermometer commonly used in industrial settings?

    <p>To measure temperature</p> Signup and view all the answers

    What does a manometer specifically measure?

    <p>Pressure in furnaces and blowers</p> Signup and view all the answers

    Which device is known for measuring temperature only above absolute zero?

    <p>Pyrometer</p> Signup and view all the answers

    What characteristic distinguishes a pressure transmitter from other pressure measurement devices?

    <p>It is electronic and controls high and low outputs.</p> Signup and view all the answers

    What type of pressure gauge can include bourdon tape, bellows, or diaphragm in its construction?

    <p>Pressure transmitter</p> Signup and view all the answers

    What is the primary function of a sight glass in process measurement?

    <p>To provide visibility into the process</p> Signup and view all the answers

    Which device can only read surface temperature and has a limited range of operation?

    <p>Portable thermocouple</p> Signup and view all the answers

    Which of the following devices is an older type of pressure measuring instrument still in use today?

    <p>Manometer</p> Signup and view all the answers

    What does a float measure in level measurement?

    <p>Height of the liquid level</p> Signup and view all the answers

    What does a D/P cell measure?

    <p>Differential pressure</p> Signup and view all the answers

    Which temperature measuring device is typically used for rotating equipment?

    <p>Portable thermocouple</p> Signup and view all the answers

    Study Notes

    Measurement Devices Overview

    • Float: Measures liquid level with a hollow ball rising to the surface. Operates in two positions.
    • Sight Glass: Measures liquid level and provides a visual window into the process within a glass tube.
    • D/P Cell: Measures level by assessing differential pressure, with a smaller bottom than the transmitter version.

    Flow Measurement Devices

    • Displacer: Measures levels through buoyancy, displacing an arm as liquid levels rise, providing differential pressure readings.
    • Orifice: Measures flow with bevel faces oriented downstream, creating pressure changes as volume increases.
    • Venturi: Offers precise measurements in low flow scenarios, smoothes displacement for minimal pressure loss.

    Temperature Measurement Instruments

    • Rotameter: Ideal for measuring small flow using gravity, commonly found in seal pumps and analyzers.
    • Thermometer: Most common is the J type, measuring temperature which can also be output via thermo-well.
    • Thermocouple & RTD: Both produce millivolt output signals; RTD measures temperature in ohms, while thermo-well provides protective casing.

    Specialized Temperature and Pressure Devices

    • Pyrometer: A portable handheld thermometer that detects surface temperatures, limited to a 100-foot range.
    • Infrared: Measures temperatures above absolute zero, suitable for non-contact assessments.
    • Pressure Gauge: Provides local analog pressure measurements utilizing bourdon tape, bellows, or diaphragm mechanisms.

    Transmitters for Process Control

    • Pressure Transmitter: A pneumatic electronic device regulating pressure in float and level systems.
    • Delta P Transmitter: Commonly used in various float and level applications to monitor fluid levels effectively.
    • Manometer: An older pressure measurement device seen in furnaces and blowers, operating with slight negative pressure readings on specific sides.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Related Documents

    Description

    Test your knowledge on the concepts of floating point representation in computer science. This quiz covers key definitions, operations, and the significance of floating points in programming. Perfect for students in computer science and programming courses.

    More Like This

    Use Quizgecko on...
    Browser
    Browser