Firefighting Incident Management
25 Questions
2 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the first priority in incident response?

  • Environmental conservation
  • Firefighter health and safety
  • Life safety (correct)
  • Incident stabilization
  • Which of the following is NOT part of the R.E.C.E.O.V.S strategy?

  • Overhaul
  • Exposure
  • Rescue
  • Containment (correct)
  • At what air level should a firefighter consider transitioning out of operations?

  • 100% cylinder capacity (4500 PSI)
  • 75% cylinder capacity (3375 PSI)
  • 50% cylinder capacity (2250 PSI) (correct)
  • 25% cylinder capacity (1125 PSI)
  • Which action is a tactical objective for engine companies?

    <p>Provide a water supply</p> Signup and view all the answers

    What is the minimum number of firefighters required in a Rapid Intervention Team (RIT)?

    <p>4 firefighters</p> Signup and view all the answers

    What is the second consideration when protecting exposures in an incident?

    <p>Preventing fire spread</p> Signup and view all the answers

    What is the highest priority for a ladder company during an emergency response?

    <p>Life Safety</p> Signup and view all the answers

    Which of the following is not a part of the 360 size-up checklist?

    <p>Water Supply Status</p> Signup and view all the answers

    Which situation would likely trigger defensive operations during a fire response?

    <p>Undetermined location of fire</p> Signup and view all the answers

    What does the term 'bottoms up' refer to in attic fire plays?

    <p>Attacking fire from the interior of the structure</p> Signup and view all the answers

    Which of the following benchmarks is typically reported first on the radio during fire operations?

    <p>Size-Up</p> Signup and view all the answers

    In the context of fire response, what is the significance of identifying potential flow paths?

    <p>To assess the risk of fire spreading</p> Signup and view all the answers

    What is the first action to take when addressing a fire where the garage door fails?

    <p>First attack line to main body of fire</p> Signup and view all the answers

    In the case of an intact garage door, what method should be used for initial knockdown?

    <p>Apply water directly into the garage</p> Signup and view all the answers

    What action is performed after confirming there is no fire in concealed spaces during a fire response?

    <p>Use PPV to pressurize the house</p> Signup and view all the answers

    What characterizes a townhouse apartment?

    <p>More than one floor with an interior stairwell</p> Signup and view all the answers

    Which type of apartment is accessed by an interior hallway?

    <p>Interior or center hallway apartment building</p> Signup and view all the answers

    What should be done after applying water for initial knockdown in an intact garage?

    <p>Cut the garage door and complete the removal</p> Signup and view all the answers

    What is the primary focus of the 360-Size Up process?

    <p>Evaluating potential rescue options</p> Signup and view all the answers

    Which factor is NOT part of the Adults Criteria for fire operations?

    <p>Communication with the public</p> Signup and view all the answers

    In the context of attic fire plays, what does the 'Bottoms Up' approach involve?

    <p>Making a small hole to apply hose stream from inside</p> Signup and view all the answers

    What is the purpose of the 'Gable End' attack method?

    <p>To initiate a knockdown on a fire adjacent to the gable</p> Signup and view all the answers

    Which statement correctly describes the 'Eve Attack' fire strategy?

    <p>Water is applied to the underside of the decking after accessing through soffits.</p> Signup and view all the answers

    Which characteristic is critical for determining defensive operations in fire management?

    <p>Fire size and behavior analysis</p> Signup and view all the answers

    What is a crucial element to consider in the 360-Size Up regarding the physical structure?

    <p>Potential rescue leads</p> Signup and view all the answers

    Study Notes

    Incident Priorities

    • Prioritize life safety above all.
    • Ensure firefighter health and safety during operations.
    • Stabilize incident conditions promptly.
    • Conserve property to minimize damage.
    • Protect the environment from harmful impacts.

    R.E.C.E.O.V.S

    • Rescue: Focus on saving any trapped individuals.
    • Exposure: Protect surrounding structures and environments.
    • Confinement: Prevent fire spread beyond the initial location.
    • Extinguishment: Actively put out the fire using suitable methods.
    • Overhaul: Check for hidden fires post-extinguishment.
    • Ventilation: Remove smoke and heat for safety and visibility.
    • Salvage: Save property and reduce damage during firefighting.

    Air Management

    • Check air levels upon entering new locations or floors.
    • Develop a clear exit strategy before making entry.
    • Transition from operations when air reaches 50% capacity (2250 PSI).

    Engine Companies Tactical Objectives

    • Size-up incident and locate fire source effectively.
    • Use hoseline to confine fire, prioritizing occupant safety.
    • Extinguish fire using appropriate hoseline and nozzle combination.
    • Protect exposures by ensuring life safety and preventing fire spread.
    • Conduct primary search for interior exposures on upper floors or adjacent businesses.
    • Establish a reliable water supply for firefighting.
    • Rapid Intervention Team (RIT) should consist of a minimum of 4 firefighters, including an officer.

    Ladder Company Tactical Objectives

    • Perform search and rescue operations.
    • Conduct ventilation to clear smoke.
    • Execute forcible entry when necessary.
    • Engage in salvage to minimize damage.
    • Carry out overhaul for complete incident resolution.

    Ladder Company Priority

    • Focus on life safety first.
    • Ensure proper ventilation to improve conditions.
    • Prioritize forcible entry and access with ladders.
    • Attend to utilities, conduct overhaul, and facilitate salvage.

    Benchmarks on the Radio

    • Communicate size-up findings promptly.
    • Perform a thorough 360 degree size-up of the scene.
    • Confirm entry into the structure.
    • Report when water is applied to the fire.
    • Announce when the fire is under control.

    360-Size Up

    • Assess potential for rescue scenarios.
    • Identify potential pathways for fire flow.
    • Determine the location and extent of the fire.
    • Evaluate the size, construction type, and age of buildings.
    • Check structural stability for safety.
    • Identify hazards to protect responders.

    Adults Criteria

    • Respond to advanced fire conditions upon arrival.
    • Implement defensive operations as necessary.
    • Be prepared for undetermined fire locations.
    • Tackle large and compartmented areas effectively.
    • Recognize when significant water volume is necessary.
    • Manage standpipe operations for water supply.

    Attic Fire Plays

    • Bottoms Up: Attack fire from within the structure, accessing either directly or through small openings.
    • Eve Attack: Apply water via soffit or bird block openings to wet decking underside; complete extinguishment involves pulling the ceiling.
    • Top Down: Use a smoke indicator hole for initial water application, followed by opening the roof for complete extinguishment.
    • Gable End: Apply initial knockdown if fire is close to the gable, followed by further attacks for complete suppression.

    Garage Fire Plays

    • Garage Door Fails: Deploy first line to main fire body for knockdown, second line inside residence, conduct primary search, check for extensions, and use PPV after confirming no concealed fires.
    • Garage Door Intact: Create a small triangular hole for water application, complete cutting after cooling the main fire body.
    • Second Line Inside Residence: Conduct primary search and extension checks, use PPV after confirming concealed spaces are clear.

    Apartment Types

    • Multi-Family: Garden apartments feature exterior access via stairwells or balconies.
    • Townhouse Apartments: Multiple floors connected by internal stairwells within the unit.
    • Interior or Center Hallway Apartment Building: Occupancy on a single floor with access through an interior hallway.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    Test your knowledge on firefighting incident priorities and the R.E.C.E.O.V.S method. This quiz covers essential air management practices to ensure safety during operations. Assess your understanding of these critical concepts to improve firefighting tactics.

    More Like This

    TN 106.13- Size-Up
    6 questions

    TN 106.13- Size-Up

    ProtectiveJackalope4164 avatar
    ProtectiveJackalope4164
    Firefighting Tactics Chapter 6
    49 questions
    202.05C Tactical Level of Air Management
    13 questions
    Use Quizgecko on...