Podcast
Questions and Answers
The F-01 test consists of 25 multiple-choice questions.
The F-01 test consists of 25 multiple-choice questions.
False
The F-92 Certificate of Fitness can be tested separately from the F-03 and F-04 tests.
The F-92 Certificate of Fitness can be tested separately from the F-03 and F-04 tests.
True
Cash payments are accepted for the application fee.
Cash payments are accepted for the application fee.
False
The F-01 exam can be taken at various locations, including online.
The F-01 exam can be taken at various locations, including online.
Signup and view all the answers
A building undergoing demolition is classified as having very likely hazardous materials.
A building undergoing demolition is classified as having very likely hazardous materials.
Signup and view all the answers
Theaters are classified under Group B occupancy.
Theaters are classified under Group B occupancy.
Signup and view all the answers
Bars and restaurants are classified under Group A-2 occupancy.
Bars and restaurants are classified under Group A-2 occupancy.
Signup and view all the answers
Indoor sporting events with spectator seating fall under Group A-5 occupancy.
Indoor sporting events with spectator seating fall under Group A-5 occupancy.
Signup and view all the answers
Classrooms with 75 persons or more are classified as Group A-3 occupancy.
Classrooms with 75 persons or more are classified as Group A-3 occupancy.
Signup and view all the answers
Civic administration offices are considered to have a moderately likely hazard classification.
Civic administration offices are considered to have a moderately likely hazard classification.
Signup and view all the answers
Swimming pools are classified under Group A-4 occupancy.
Swimming pools are classified under Group A-4 occupancy.
Signup and view all the answers
Educational occupancies above the 12th grade are not classified under Group B.
Educational occupancies above the 12th grade are not classified under Group B.
Signup and view all the answers
All apartment buildings built after March 1999 are required to have a fire sprinkler system.
All apartment buildings built after March 1999 are required to have a fire sprinkler system.
Signup and view all the answers
The purpose of fire sprinklers is solely to enhance the aesthetic appeal of a building.
The purpose of fire sprinklers is solely to enhance the aesthetic appeal of a building.
Signup and view all the answers
Water reactive materials do not pose any risks in the vicinity of fire sprinkler systems.
Water reactive materials do not pose any risks in the vicinity of fire sprinkler systems.
Signup and view all the answers
When the sprinkler system is out-of-service, it can still be used to extinguish fires.
When the sprinkler system is out-of-service, it can still be used to extinguish fires.
Signup and view all the answers
Sprinkler heads are typically opened by a heat-sensitive releasing mechanism.
Sprinkler heads are typically opened by a heat-sensitive releasing mechanism.
Signup and view all the answers
The S-12 COF holder is accountable for checking the sprinkler system's compliance with the 2014/2022 NYC Fire Code.
The S-12 COF holder is accountable for checking the sprinkler system's compliance with the 2014/2022 NYC Fire Code.
Signup and view all the answers
Standpipe systems provide firefighters with fast access to water during a fire emergency.
Standpipe systems provide firefighters with fast access to water during a fire emergency.
Signup and view all the answers
Standpipe systems are only installed in residential buildings.
Standpipe systems are only installed in residential buildings.
Signup and view all the answers
Portable fire extinguishers are designed to extinguish large or spreading fires.
Portable fire extinguishers are designed to extinguish large or spreading fires.
Signup and view all the answers
Class A fires can be extinguished with water or certain dry chemicals.
Class A fires can be extinguished with water or certain dry chemicals.
Signup and view all the answers
If a fire extinguisher is discharged, work can continue as long as the area is clear.
If a fire extinguisher is discharged, work can continue as long as the area is clear.
Signup and view all the answers
The acronym P.A.S.S. stands for Pull, Aim, Squeeze, and Sweep.
The acronym P.A.S.S. stands for Pull, Aim, Squeeze, and Sweep.
Signup and view all the answers
Fire guards are responsible for extinguishing fires when they are large.
Fire guards are responsible for extinguishing fires when they are large.
Signup and view all the answers
To use a fire extinguisher, one should first aim at the base of the fire.
To use a fire extinguisher, one should first aim at the base of the fire.
Signup and view all the answers
The Fire Guard Certificate of Fitness holder must know how to use a fire extinguisher improperly.
The Fire Guard Certificate of Fitness holder must know how to use a fire extinguisher improperly.
Signup and view all the answers
Flammable liquids and gases cause Class B fires.
Flammable liquids and gases cause Class B fires.
Signup and view all the answers
Using unauthorized batteries and chargers cannot void your warranty.
Using unauthorized batteries and chargers cannot void your warranty.
Signup and view all the answers
Lithium-Ion batteries can potentially re-ignite after all visible flames have been extinguished.
Lithium-Ion batteries can potentially re-ignite after all visible flames have been extinguished.
Signup and view all the answers
Fire extinguishers are effective in putting out fires caused by lithium-ion batteries.
Fire extinguishers are effective in putting out fires caused by lithium-ion batteries.
Signup and view all the answers
The battery management system (BMS) ensures that any battery or charger combination is safe to use.
The battery management system (BMS) ensures that any battery or charger combination is safe to use.
Signup and view all the answers
Water is an effective method to extinguish lithium-ion battery fires.
Water is an effective method to extinguish lithium-ion battery fires.
Signup and view all the answers
A fire watch is required when the building is fully occupied and the core loop system is out of service.
A fire watch is required when the building is fully occupied and the core loop system is out of service.
Signup and view all the answers
Hot work is not allowed when the fire alarm system sprinkler water flow alarm is out of service.
Hot work is not allowed when the fire alarm system sprinkler water flow alarm is out of service.
Signup and view all the answers
Building compartmentation can be removed indefinitely without any regulations if it served as passive fire protection.
Building compartmentation can be removed indefinitely without any regulations if it served as passive fire protection.
Signup and view all the answers
No fire watch is needed when the entire building is vacant or evacuated, except in special circumstances.
No fire watch is needed when the entire building is vacant or evacuated, except in special circumstances.
Signup and view all the answers
Approval for the removal of any fire protection system must be obtained from the Fire Department.
Approval for the removal of any fire protection system must be obtained from the Fire Department.
Signup and view all the answers
An impairment coordinator is unnecessary if the core loop system remains installed but out of service.
An impairment coordinator is unnecessary if the core loop system remains installed but out of service.
Signup and view all the answers
Hot work is allowed when the core loop system is neither installed nor approved.
Hot work is allowed when the core loop system is neither installed nor approved.
Signup and view all the answers
Fire watches are always required when the core loop system is in service.
Fire watches are always required when the core loop system is in service.
Signup and view all the answers
Study Notes
Fire Guard for Impairment (Citywide)
- Applicants must apply and pay for the exam online before arriving at the FDNY.
- Online application and payment takes approximately 30 minutes to complete.
- Simplified instructions are available at: http://www1.nyc.gov/assets/fdny/downloads/pdf/business/fdny-business-cof-individuals-short.pdf
- Create an account and log in to: http://fires.fdnycloud.org/CitizenAccess
Exam Specific Information for F-01 Certificate of Fitness
- All applicants required to apply and pay for an exam online before arriving at FDNY.
- Exam takes approximately 30 minutes to complete.
- Simplified instructions available at: http://www1.nyc.gov/assets/fdny/downloads/pdf/business/fdny-business-cof-individuals-short.pdf
- Create an account and log in to: http://fires.fdnycloud.org/CitizenAccess
- Application fee: $25.
- Payment methods: Credit card, debit card, personal/company check, or money order.
- Convenience fee of 2% is applied to all credit card payments.
- Fee waivers available for government employees.
- A letter asking for a fee waiver is required along with a copy of the applicant's identification card issued by the agency.
- No alternative issuance procedure (AIP) available.
- Exam administered online at FDNY headquarters.
Exam Information
- The F-01 test consists of 20 multiple-choice questions.
- The test is administered on a touch-screen computer monitor.
- The test duration is 30 minutes.
- A passing score of at least 70% is required.
- Contact (718) 999-1988 for further information and forms.
- Check FDNY website for updated information and materials: http://www1.nyc.gov/assets/fdny/downloads/pdf/business/cof-f01-noe-study-materials.pdf
- Current F-92 certificates of fitness are valid and renewable.
- F-03, F-04, and F-92 certificate of fitness tests are available as separate tests.
- Exam site: FDNY Headquarters, 9 MetroTech Center, Brooklyn, NY, between Myrtle Avenue and Tech Place.
Renewal Requirements
- Review general exam notice available at: http://www1.nyc.gov/assets/fdny/downloads/pdf/business/general-notice-of-exam-cof.pdf
- Special renewal requirements for F-01 COF: None.
- FDNY recommends online renewal. Simplified online renewal instructions are available at http://www1.nyc.gov/assets/fdny/downloads/pdf/business/cof-simplified-renewal-short.pdf
- Questions? Contact FDNY Business Support Team at 311, or email [email protected]
Study Material and Test Description
- The study material will help prepare for the Certificate of Fitness exam for fire guards for impairment.
- The study material consists of 2 parts
- The exam covers the entire booklet. The booklet will not be provided during the test.
- The material includes information from the New York City Fire Code (2022).
- It's crucial to understand the booklet to pass the exam.
- The study material does not include all the rules and regulations required to work as a fire guard.
- Students are responsible for familiarizing themselves with the relevant sections of the New York City Fire Code (2022).
- Reference the 2022 Fire Code sections 401.3, 408, 901, 906 and NFPA 25 chapter 14 (2002 Ed.)
Part 1: Requirements and Duties
- Fire guards are trained to reduce the threat of fires in various locations.
- Fire guards are responsible for maintaining a fire watch.
- Fire guards should have general knowledge of portable fire extinguishers and alarm pull stations.
- Fire guards must inspect assigned areas every hour, for smoke/fire hazards.
- Report any problems immediately to the building owner.
- Locations inspected may vary.
- Check exits, stairways, hallways, and doors for blockage.
- Ensure self-closing doors are not obstructed.
- Check for emergency lighting, exit signs, and locations of portable fire extinguishers.
- Fire guard must enforce no smoking policies in the area and inspect for buildup of trash/rubbish.
- Keep an inspection record for at least 48 hours.
Part 2: Fire Protection System and Fire Extinguishers
- Sprinkler system
- Standpipe system
- Fire alarm system
- Portable fire extinguishers
Part 3: Lithium-Ion Battery Safety
- Lithium-ion batteries are rechargeable batteries in electric devices (bikes, scooters, cars, laptops, tablets, and phones).
- Fires caused by these batteries have resulted in significant damage to property.
- Appropriate safety procedures must be followed to prevent fires, explosions.
- Immediate action and notification to 911 is required if a fire or smoke is detected.
Appendix A
- Guidelines for impairment firefighters, fire watch requirements, and hot work restrictions for out-of-service fire protection systems at construction sites.
- The conditions for a possible out-of-service fire protection system at construction sites are covered.
Definitions
- Fire Guard
- Fire Watch
- Impairment
- Impairment Coordinator
- Planned Out of Service Condition
- Unplanned Out of Service Condition
Studying That Suits You
Use AI to generate personalized quizzes and flashcards to suit your learning preferences.
Related Documents
Description
Prepare for the F-01 Certificate of Fitness exam with this comprehensive guide. Applicants must complete their online application and payment before arriving at the FDNY. Familiarize yourself with the exam process, fees, and instructions to ensure a smooth experience.