Which areas are required to have emergency lighting with an average level of illumination of not less than 10 lx at floor or tread level?
What is the minimum value of illumination required by the National Building Code of Canada for emergency lighting?
In buildings or parts thereof where treatment is provided, what additional requirements apply to the installation of battery-operated emergency lighting?
What is the minimum duration that an emergency power supply must assume the electrical load automatically in the event of a regular power failure for buildings within the scope of Subsection 3.2.6?
Signup and view all the answers
According to the National Building Code of Canada 2015, when is a voice communication system required in a building?
Signup and view all the answers
According to the National Building Code of Canada 2015, what systems need to be tested to ensure satisfactory operation?
Signup and view all the answers
What is the emergency power supply required for fire alarm systems capable of providing?
Signup and view all the answers
According to the National Building Code of Canada 2015, what is the minimum level of illumination required for an exit, public corridor, or a corridor providing access to exit for the public or serving patients’ sleeping rooms or classrooms?
Signup and view all the answers
According to the National Building Code of Canada 2015, what is the minimum value of illumination required for an exit, public corridor, or a corridor providing access to exit for the public or serving patients’ sleeping rooms or classrooms?
Signup and view all the answers
According to the National Building Code of Canada 2015, where should lighting outlets be provided in a building of residential occupancy?
Signup and view all the answers
Which of the following is a requirement for a vestibule in an exit opening into an interconnected floor space?
Signup and view all the answers
What is the purpose of a protected floor space in an interconnected floor space?
Signup and view all the answers
What is the minimum depth of a draft stop within an interconnected floor space?
Signup and view all the answers
What is the required rate of air changes per hour for a mechanical exhaust system in an interconnected floor space?
Signup and view all the answers
What is the limit for combustible contents in an interconnected floor space with a ceiling height above 8 m?
Signup and view all the answers
Which of the following occupancies are not required to be separated by fire separations in a sprinklered building?
Signup and view all the answers
What should be followed for the storage, handling, and use of hazardous substances?
Signup and view all the answers
How should systems for the ventilation of cooking equipment be designed and installed?
Signup and view all the answers
Which of the following is a subsection that provides exceptions for the storage, handling, and use of hazardous substances?
Signup and view all the answers
Where should fuel-fired systems be installed?
Signup and view all the answers
Which type of building is required to have an emergency power supply capable of operating under a full load for not less than 2 hours?
Signup and view all the answers
Which of the following is NOT required to be equipped with an annunciator?
Signup and view all the answers
Under what conditions does Sentence (2) not apply to the emergency power supply for elevators?
Signup and view all the answers
What is the minimum circuit integrity rating required for electrical conductors used in conjunction with fire alarms, emergency lighting, or emergency equipment?
Signup and view all the answers
In which type of service space should electrical conductors serving mechanical systems be located?
Signup and view all the answers
According to the National Building Code of Canada 2015, which of the following is true about fire alarm system branch circuits within a storey?
Signup and view all the answers
In accordance with the National Building Code of Canada 2015, what is the requirement for protecting power supply conductors leading up to a distribution panel that supplies power to emergency lighting?
Signup and view all the answers
According to the National Building Code of Canada 2015, which of the following is true about conductors leading from a distribution panel to emergency lighting units in the same storey?
Signup and view all the answers
According to the National Building Code of Canada 2015, what is the requirement for the installation of distribution panels serving emergency lighting units located on other storeys?
Signup and view all the answers
According to the National Building Code of Canada 2015, what is the requirement for protecting conductors leading from a distribution panel to emergency lighting units located on other storeys?
Signup and view all the answers