Electrosurgery and Electrocautery Overview
16 Questions
2 Views

Electrosurgery and Electrocautery Overview

Created by
@IntuitiveIridium

Questions and Answers

What is the primary purpose of a smoke evacuator in a surgical setting?

  • To enhance the effectiveness of electrosurgery.
  • To assist in coagulation during surgery.
  • To monitor power settings during the procedure.
  • To protect the surgical team from inhaling carcinogens. (correct)
  • In bipolar electrosurgery, which of the following statements is true?

  • It can function without a foot pedal.
  • The current flows between the two prongs only. (correct)
  • Current flows between the active electrode and a grounding pad.
  • It requires a dispersive pad for current return.
  • What is a significant risk associated with insulation failure in electrosurgery?

  • Increased blood loss during surgery.
  • Ineffective coagulation of tissues.
  • Electrical current escaping and burning surrounding tissue. (correct)
  • Overinflation of the abdomen.
  • Which phenomenon occurs when an active electrode touches a non-insulated metal instrument?

    <p>Direct coupling.</p> Signup and view all the answers

    What is one of the advantages of argon enhanced electrosurgery?

    <p>It improves coagulation efficiency and reduces blood loss.</p> Signup and view all the answers

    Which of the following is NOT recommended for preventing patient complications during electrosurgery?

    <p>Use the highest power setting for maximum effectiveness.</p> Signup and view all the answers

    In endoscopic surgery, what is essential for both monopolar and bipolar electrosurgery?

    <p>Foot pedal operation.</p> Signup and view all the answers

    What is the recommended action regarding the cords and handpiece before surgery?

    <p>Check for tangling and damage.</p> Signup and view all the answers

    What is the primary function of an Electrosurgical Unit (ESU) during surgery?

    <p>To cut and coagulate tissues using electricity</p> Signup and view all the answers

    How does monopolar electrosurgery generate heat in the tissues?

    <p>Through the flow of electricity in a closed loop</p> Signup and view all the answers

    Which mode of a monopolar electrosurgical unit is used for cutting?

    <p>Yellow mode</p> Signup and view all the answers

    What is a crucial consideration when placing the dispersive electrode pad on a patient?

    <p>It should be placed close to the surgical site</p> Signup and view all the answers

    What type of current is primarily used during electrosurgery in the operating room?

    <p>Alternating Current (AC)</p> Signup and view all the answers

    What is the significance of impedance in electrosurgery?

    <p>It generates controlled heat in the tissues</p> Signup and view all the answers

    Which of the following statements correctly describes bipolar electrosurgery?

    <p>Utilizes two electrodes that require direct contact with the tissue</p> Signup and view all the answers

    Which type of pad is referred to as the Patient Return Electrode (PRE)?

    <p>Dispersive electrode pad</p> Signup and view all the answers

    Study Notes

    Electrosurgery and Electrocautery

    • Electrosurgical Unit (ESU): Utilizes electricity to cut and coagulate tissues during surgery, applicable in both open and minimally invasive surgeries (MIS).
    • Monopolar vs. Bipolar: Monopolar utilizes one active electrode and a return pad; bipolar utilizes two prongs and does not require a dispersive pad.

    Principles of Electricity

    • Current: The flow of electricity.
    • Voltage: The force moving electrons.
    • Impedance: The resistance to current flow.
    • Direct Current (DC): Electrons flow in one direction, generating heat upon contact with tissue for burning or coagulation.
    • Alternating Current (AC): Electrons flow back and forth, used in electrosurgery in the operating room.

    Electrosurgical Modes

    • Monopolar Activation: Utilizes two buttons for activation; blue for coagulation mode and yellow for cutting mode.
    • Energy Flow:
      • Path: Generator → Active electrode → Patient → Dispersive pad → Generator
      • Controlled heat leads to coagulation, preventing patient burns.

    Dispersive Electrode Pad

    • Also known as Patient Return Electrode (PRE).
    • An adhesive, one-time use pad applied near the surgical site on well-vascularized areas.
    • Proper placement prevents heat concentration and minimizes burn risk.

    Capacitive Pads

    • Reusable "Megadyne Pad" lies beneath the patient on the OR table, suitable for larger body surface areas.

    Smoke Evacuator

    • Essential tool for removing smoke from placed cauterization to protect surgical staff from inhaling harmful substances.

    Bipolar Electrosurgery

    • Exclusively used for coagulation at lower power settings, without the need for a dispersive pad.
    • Utilizes a foot pedal; current flows solely between the two prongs.

    ESU in Endoscopic Surgery

    • Both monopolar and bipolar electrosurgery employed alongside foot pedals during endoscopic procedures.

    Risks and Complications

    • Insulation Failure: Damaged insulating covers can lead to electrical current escape and unintended burns.
    • Direct Coupling: When the active electrode touches non-insulated metal, resulting in current transfer and burns.
    • Capacitive Coupling: Electrical transfer between conductors without insulation damage; hybrid instruments can help mitigate risk.

    Argon Enhanced Electrosurgery

    • Combines argon gas with electrosurgical energy for effective current usage.
    • Benefits include quick coagulation, reduced blood loss, and lower smoke plume.
    • Caution against over-inflating the abdomen due to the risk of gas embolism.

    Electro Thermal Sealing Devices

    • Example: Ligasure, used for bipolar vessel sealing.

    Scrub Role in OR

    • Maintain cleanliness and dryness of handpiece holders, monitor power settings, and ensure no damage to cords or handpieces.
    • Active electrode tips should be cleaned adequately during procedures.

    Prevention of Patient Complications

    • Inspect instrument insulation regularly, use the lowest effective power setting, opt for bipolar procedures when suitable, and employ quick, intermittent activation to minimize risks.

    Studying That Suits You

    Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

    Quiz Team

    Description

    This quiz covers the fundamentals of electrosurgery and electrocautery, including the principles of electricity relevant to these techniques. It explores the differences between monopolar and bipolar systems, the modes of operation, and the flow of energy during surgical procedures. Test your knowledge of these crucial concepts in modern surgery.

    More Quizzes Like This

    Electrosurgery Safety Precautions
    17 questions

    Electrosurgery Safety Precautions

    UnquestionableDidgeridoo avatar
    UnquestionableDidgeridoo
    Electrosurgery Generators Basics
    12 questions
    Dispositivos Médicos: Electrobisturíes
    22 questions
    Electrosurgery Module 5 Quiz
    37 questions
    Use Quizgecko on...
    Browser
    Browser