Which control is used to switch the glue pot between operating and standby temperatures?
Which control is used to switch the glue pot between operating and standby temperatures?
- Temperature Key (correct)
- Edging Reel Key
- Standby Activation Key
- Power Control
What is the purpose of the 'Slats Key' on the edge bander's control panel?
What is the purpose of the 'Slats Key' on the edge bander's control panel?
- To allow the machine to use solid edges (correct)
- To switch between different glue types
- To control the feed belt speed
- To enable the end trimming unit
What is the typical temperature range for the glue pot's standby setting?
What is the typical temperature range for the glue pot's standby setting?
- 150-200 degrees Celsius
- 190-220 degrees Celsius
- 200-250 degrees Celsius
- 100-160 degrees Celsius (correct)
What is the primary function of the Emergency Power button on the edge bander?
What is the primary function of the Emergency Power button on the edge bander?
If the standby activation time is set to 10 minutes, what does this determine?
If the standby activation time is set to 10 minutes, what does this determine?
Flashcards
Temperature Key
Temperature Key
Controls the temperature of the glue pot. Switches between standby and operating temperature automatically.
End Trimmer Key
End Trimmer Key
Starts and stops the end trimming unit. Used to remove excess edging material.
Edging Reel Key
Edging Reel Key
Allows the edge bander to work with banding that is supplied from a reel holder.
Power Control
Power Control
Signup and view all the flashcards
Emergency Power Button
Emergency Power Button
Signup and view all the flashcards
Study Notes
Edge Bander Main Control Panel
- The control panel allows operators to turn the machine on/off, and adjust various settings, including temperature and infeed.
- It allows control of the glue pot temperature and the time for automatic stand-by activation.
- Operating temperature range: 190-220 degrees Celsius
- Stand-by temperature range: 100-160 degrees Celsius
- Stand-by activation time range: 4-30 minutes
Control Panel Functions
- A: Edging Reel Key: Enables machine operation with banding on the reel holder.
- B: Temperature Key: Switches the glue pot between stand-by and operating temperatures.
- C: End Trimmer Key: Enables the end trimming unit.
- D: Emergency Power Button: Immediately cuts the power supply to the machine.
- E: Power Control: Starts the machine.
- F: Feed Belt Control: Turns the infeed belt on or off.
- G: Trimming Head Stop: Stops trimming head operations.
- H: Trimming Head Start: Starts trimming head operations.
- I: Slats Key: Enables the machine to work with solid edges.