Components of Building Services Quiz
12 Questions
4 Views

Choose a study mode

Play Quiz
Study Flashcards
Spaced Repetition
Chat to Lesson

Podcast

Play an AI-generated podcast conversation about this lesson

Questions and Answers

What is the minimum occupant load that requires dressing rooms, rehearsal rooms, workshops, or factories to have fire extinguishers?

  • 15
  • 10 (correct)
  • 20
  • 5

In addition to dressing rooms and workshops, what other types of rooms require fire extinguishers if they have an occupant load over 500?

  • Group J and K occupancies
  • Group G occupancies
  • Group L and M occupancies
  • Group H and I occupancies (correct)

What is the maximum distance allowed from the nearest room to a safe fire dispersal area before requiring fire extinguishers?

  • 30 meters (correct)
  • 20 meters
  • 25 meters
  • 35 meters

In what type of rooms are fire extinguishers required for storage or handling of flammable materials?

<p>All of the above (D)</p> Signup and view all the answers

What is the minimum building height that requires dry standpipes?

<p>4 storeys (C)</p> Signup and view all the answers

What material(s) are dry standpipes allowed to be constructed from according to the text?

<p>Both wrought iron and galvanized steel (D)</p> Signup and view all the answers

What is the minimum number of accessible water closets required on each floor level for 20 or fewer total water closets?

<p>1 (A)</p> Signup and view all the answers

What is the maximum height allowed for water closets as per the requirements?

<p>0.45 m (B)</p> Signup and view all the answers

Which of the following is NOT a component of building services mentioned in the text?

<p>Landscaping services (D)</p> Signup and view all the answers

What is the minimum turning space required outside a closet stall for wheelchairs?

<p>2.25 sq.m. (C)</p> Signup and view all the answers

What is the maximum height allowed for lavatories?

<p>0.80 m (D)</p> Signup and view all the answers

Which of the following systems is mentioned in the text as part of mechanical services?

<p>Heating, Ventilation, and Air Conditioning (HVAC) system (D)</p> Signup and view all the answers

Study Notes

Fire Extinguisher Requirements

  • A minimum occupant load of 100 requires dressing rooms, rehearsal rooms, workshops, or factories to have fire extinguishers.
  • In addition to dressing rooms and workshops, assembly areas with an occupant load over 500 also require fire extinguishers.
  • Fire extinguishers are necessary if any room is more than 75 feet away from a safe fire dispersal area.
  • Fire extinguishers are mandated in rooms used for storage or handling of flammable materials.

Building Safety Features

  • A minimum building height of 75 feet requires the installation of dry standpipes.
  • Dry standpipes can be constructed from materials such as steel, cast iron, or other approved materials.

Accessibility Standards

  • For buildings with 20 or fewer total water closets, a minimum of 1 accessible water closet is required on each floor level.
  • The maximum height allowed for water closets is 17-19 inches for accessibility compliance.

Additional Specifications

  • Lavatories must be installed no higher than 34 inches from the finish floor to accommodate accessibility needs.
  • A minimum turning space of 60 inches in diameter is required outside a closet stall for wheelchair accessibility.
  • Components of building services include plumbing systems, HVAC systems, and electrical systems, while a specific unreferred system is not part of the text provided.

Mechanical Services

  • Mechanical services mentioned include heating, ventilation, and air conditioning (HVAC) systems, ensuring proper climate control within buildings.

Studying That Suits You

Use AI to generate personalized quizzes and flashcards to suit your learning preferences.

Quiz Team

Description

Test your knowledge on the components of building services including sanitary, electrical, mechanical, and fire protection systems. This quiz also covers specific requirements for plumbing and sanitary services according to RA 6541, such as dimensions and accessibility standards.

More Like This

Building Services Components Quiz
12 questions
Building Services Components Quiz
12 questions
Building Services Engineering Quiz
36 questions

Building Services Engineering Quiz

SweetheartMandelbrot1035 avatar
SweetheartMandelbrot1035
Use Quizgecko on...
Browser
Browser